Preparation and characterization of hybrid-silica monolithic column with mixed-mode of hydrophilic and strong anion-exchange interactions for pressurized capillary electrochromatography

被引:31
|
作者
Wang, Xiao [1 ]
Zheng, Yanqiong [1 ]
Zhang, Chunyuan [1 ]
Yang, Yanzhong [1 ]
Lin, Xucong [1 ]
Huang, Guihua [2 ]
Xie, Zenghong [1 ,3 ]
机构
[1] Fuzhou Univ, Inst Food Safety & Environm Monitoring, Fuzhou 350108, Peoples R China
[2] Fujian Univ Tradit Chinese Med, Fuzhou 350108, Peoples R China
[3] Xiamen Huaxia Vocat Coll, Xiamen 361024, Peoples R China
关键词
Hybrid-silica monolithic column; Mixed-mode; Hydrophilic and strong anion-exchange interactions; Pressurized capillary electrochromatography; STATIONARY-PHASE; INTERACTION CHROMATOGRAPHY; LIQUID-CHROMATOGRAPHY; ACIDIC COMPOUNDS; SEPARATION; POLAR; PEPTIDES;
D O I
10.1016/j.chroma.2012.03.071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel organic-silica hybrid monolithic stationary phase with a mixed-mode of hydrophilic and strong anion-exchange interactions (HI-SAX) was prepared with a modified "one-pot" process of functional monomers and alkoxysilanes. Using a hydrosoluble initiator 2,2'-azobis(2-methylpropionamidine) dihydrochloride (AIBA), the homogeneous prepolymerization system of this hybrid monolith was successfully obtained by a simple operation. The polycondensation of alkoxysilanes (tetramethoxysilane (TMOS) and vinyl-trimethoxysilane (VTMS)) and the in situ copolymerization of a quaternary ammonium group-containing acrylic monomer ([2-(acryloyloxy)ethyl] trimethyl ammonium methyl sulfate (AETA)) on the precondensed siloxanes were achieved. The morphologies of the hybrid-silica monolithic matrixes were observed by SEM, and the performances of the organic-silica hybrid monolithic columns were investigated by pressurized capillary electrochromatography. The mechanical stability and reproducibility of the obtained hybrid monolithic column preformed acceptable. Both hydrophilic interaction chromatography mechanism and strong anion-exchanged interaction were investigated. A mixed mode of HI-SAX was obtained for the analysis of nucleotides with a good resolution, and the separation of polar and basic nucleic acid bases and nucleosides was also achieved without peak tailing. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 50 条
  • [1] Preparation and characterization of dipyridine modified hybrid-silica monolithic column for mixed-mode capillary electrochromatography
    Tang, Sheng
    Wang, Licheng
    Han, Haifeng
    Qiu, Hongdeng
    Liu, Xia
    Jiang, Shengxiang
    RSC ADVANCES, 2013, 3 (21): : 7894 - 7901
  • [2] Preparation and characterization of mixed-mode monolithic silica column for capillary electrochromatography
    Ye, Fanggui
    Wang, Shun
    Zhao, Shulin
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (51) : 8845 - 8850
  • [3] Sulfoalkylbetaine-based monolithic column with mixed-mode of hydrophilic interaction and strong anion-exchange stationary phase for capillary electrochromatography
    Wang, Xiaochun
    Ding, Kang
    Yang, Chunmei
    Lin, Xucong
    Lue, Haixia
    Wu, Xiaoping
    Xie, Zenghong
    ELECTROPHORESIS, 2010, 31 (17) : 2997 - 3005
  • [4] Quinine-modified polymer monolithic column with reversed-phase /strong anion-exchange mixed-mode for pressurized capillary electrochromatography
    Wang, Jiabin
    Ding, Changying
    Xiao, Jianhua
    Jia, Wenchao
    Chen, Yongxuan
    Lin, Xucong
    Xie, Zenghong
    ELECTROPHORESIS, 2018, 39 (12) : 1504 - 1511
  • [5] Monolithic silica columns with mixed mode of hydrophilic interaction and weak anion-exchange stationary phase for pressurized capillary electrochromatography
    Ye, Fanggui
    Xie, Zenghong
    Wong, Kwok-Yin
    ELECTROPHORESIS, 2006, 27 (17) : 3373 - 3380
  • [6] Preparation of weak anion-exchange silica monolithic column for capillary electrochromatography
    Yan, LJ
    Zhang, LY
    Zhang, QH
    Li, T
    Feng, YQ
    Zhang, WB
    Zhang, YK
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (01) : 1 - 4
  • [7] Novel highly hydrophilic methacrylate-based monolithic column with mixed-mode of hydrophilic and strong cation-exchange interactions for pressurized capillary electrochromatography
    Lin, Jia
    Liu, Shaofeng
    Lin, Jian
    Lin, Xucong
    Xie, Zenghong
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (29) : 4671 - 4677
  • [8] Preparation and evaluation of mixed-mode silica monolithic column for capillary electrochromatography
    Ding Guosheng
    Da Zhenliang
    Yuan Ruijuan
    Bao Jianmin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 : S68 - S72
  • [9] Reversed-phase and weak anion-exchange mixed-mode silica-based monolithic column for capillary electrochromatography
    Ding, Guosheng
    Da, Zhenliang
    Yuan, Ruijuan
    Bao, James J.
    ELECTROPHORESIS, 2006, 27 (17) : 3363 - 3372
  • [10] Vinylbenzyl quaternary ammonium-based polymeric monolith with hydrophilic interaction/strong anion exchange mixed-mode for pressurized capillary electrochromatography
    Lin, Xucong
    Feng, Shuhui
    Jia, Wenchao
    Ding, Kang
    Xie, Zenghong
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1316 : 104 - 111