Impact of cleaning regimes on dental water unit contamination

被引:7
|
作者
Abdallah, Soad A. [1 ]
Khalil, Ahmed I. [2 ]
机构
[1] PAAET, Coll Nursing, Gen Sci Unit, Dept Microbiol, Kuwait, Kuwait
[2] Mubarak Al Kabeer Hosp, Head Prevent Med Dept, Kuwait, Kuwait
关键词
bacterial contamination; chlorination; dental unit waterline; flushing; MICROBIAL BIOFILM FORMATION; SYSTEMS; LINES; DISINFECTION; EFFICACY;
D O I
10.2166/wh.2011.184
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microorganisms that have been identified in dental unit waterlines (DUWLs) are of concern because they can cause infections, especially in immunocompromised patients. This study aimed to assess the incidence of microbial contamination in DUWLs before and after intervention to reduce contamination, and to investigate the presence of coliforms, Escherichia coli and Pseudomonas aeruginosa. Water samples were collected aseptically from the waterlines. The high-speed hand-piece and dental chair units were served by one distillation apparatus, which was fed by the potable tap water of four dental clinics. Different interventions were used: chlorination, flushing before clinics and between patients, draining at the end of the day, and freshly distilled water on a daily basis. There was a significant difference between the level of contamination in the high-speed hand-piece (1.5-2.7 log CFU/ml) and dental chair unit water (2.0-3.5 log CFU/ml). Coliforms (0.9%) E. coli (0.9%) and Pseudomonas (1.8%) were detected during 2008. This study indicates the need to monitor water quality regularly and prevent stagnation in DUWLs to reduce the number of viable bacteria to <100 CFU/ml. We recommend flushing the DUWL for 2 min before the first patient and for 10-20 s between patients, flushing the dental unit at the end of the day and draining it overnight to reduce the development of biofilms, and chlorination of the DUWLs.
引用
收藏
页码:647 / 652
页数:6
相关论文
共 50 条
  • [31] Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
    Okubo, Keisuke
    Ito, Takashi
    Okamoto, Kentaro
    Yamamoto, Ichiro
    Mizutani, Hajime
    Kawata, Yusuke
    Shiota, Yasuyoshi
    Ito, Masahiro
    Nakamura, Shin
    Tai, Masako
    Yamamoto, Tadashi
    Takashiba, Shogo
    HELIYON, 2020, 6 (06)
  • [32] Efficacy of a Low Dose of Hydrogen Peroxide (Peroxy Ag+) for Continuous Treatment of Dental Unit Water Lines: Challenge Test with Legionella pneumophila Serogroup 1 in a Simulated Dental Unit Waterline
    Ditommaso, Savina
    Giacomuzzi, Monica
    Ricciardi, Elisa
    Zotti, Carla M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2016, 13 (07):
  • [33] Plasma Sterilization Effectively Reduces Bacterial Contamination in Dental Unit Waterlines
    Noopan, Sarocha
    Unchui, Phattranit
    Techotinnakorn, Supitcha
    Ampornaramveth, Ruchanee Salingcarnboriboon
    INTERNATIONAL JOURNAL OF DENTISTRY, 2019, 2019
  • [34] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Kadaifciler, Duygu Goksay
    Cotuk, Aysin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (06) : 3431 - 3444
  • [35] Bacterial contamination of new dental unit waterlines and efficacy of shock disinfection
    Baudet, Alexandre
    Lizon, Julie
    Lozniewski, Alain
    Florentin, Arnaud
    Mortier, Eric
    BMC MICROBIOLOGY, 2024, 24 (01):
  • [36] Microbial quality of water in dental unit waterlines
    Nikaeen, Mahnaz
    Hatamzadeh, Maryam
    Sabzevari, Zohre
    Zareh, Omolbanin
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2009, 14 (05): : 297 - 300
  • [37] Microbial quality of water in dental unit reservoirs
    Szymanska, J
    Wdowiak, L
    Puacz, E
    Stojek, NM
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2004, 11 (02) : 355 - 358
  • [38] Cleaning, disinfection and sterilization of surface prion contamination
    McDonnell, G.
    Dehen, C.
    Perrin, A.
    Thomas, V.
    Igel-Egalon, A.
    Burke, P. A.
    Deslys, J. P.
    Comoy, E.
    JOURNAL OF HOSPITAL INFECTION, 2013, 85 (04) : 268 - 273
  • [39] Evaluation of Microbiological and Free-Living Protozoa Contamination in Dental Unit Waterlines
    Spagnolo, Anna Maria
    Sartini, Marina
    Di Cave, David
    Casini, Beatrice
    Tuvo, Benedetta
    Cristina, Maria Luisa
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (15)
  • [40] Microbial control of dental unit water: Feedback on different disinfection methods experience
    Lizon, Julie
    Florentin, Arnaud
    Martrette, Jean-Marc
    Rivier, Alexandre
    Clement, Celine
    Rabaud, Christian
    AMERICAN JOURNAL OF INFECTION CONTROL, 2016, 44 (02) : 247 - 249