Impact of cleaning regimes on dental water unit contamination

被引:7
|
作者
Abdallah, Soad A. [1 ]
Khalil, Ahmed I. [2 ]
机构
[1] PAAET, Coll Nursing, Gen Sci Unit, Dept Microbiol, Kuwait, Kuwait
[2] Mubarak Al Kabeer Hosp, Head Prevent Med Dept, Kuwait, Kuwait
关键词
bacterial contamination; chlorination; dental unit waterline; flushing; MICROBIAL BIOFILM FORMATION; SYSTEMS; LINES; DISINFECTION; EFFICACY;
D O I
10.2166/wh.2011.184
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microorganisms that have been identified in dental unit waterlines (DUWLs) are of concern because they can cause infections, especially in immunocompromised patients. This study aimed to assess the incidence of microbial contamination in DUWLs before and after intervention to reduce contamination, and to investigate the presence of coliforms, Escherichia coli and Pseudomonas aeruginosa. Water samples were collected aseptically from the waterlines. The high-speed hand-piece and dental chair units were served by one distillation apparatus, which was fed by the potable tap water of four dental clinics. Different interventions were used: chlorination, flushing before clinics and between patients, draining at the end of the day, and freshly distilled water on a daily basis. There was a significant difference between the level of contamination in the high-speed hand-piece (1.5-2.7 log CFU/ml) and dental chair unit water (2.0-3.5 log CFU/ml). Coliforms (0.9%) E. coli (0.9%) and Pseudomonas (1.8%) were detected during 2008. This study indicates the need to monitor water quality regularly and prevent stagnation in DUWLs to reduce the number of viable bacteria to <100 CFU/ml. We recommend flushing the DUWL for 2 min before the first patient and for 10-20 s between patients, flushing the dental unit at the end of the day and draining it overnight to reduce the development of biofilms, and chlorination of the DUWLs.
引用
收藏
页码:647 / 652
页数:6
相关论文
共 50 条
  • [21] Efficacy of anti-retraction devices in preventing bacterial contamination of dental unit water lines
    Berlutti, F
    Testarelli, L
    Vaia, F
    De Luca, M
    Dolci, G
    JOURNAL OF DENTISTRY, 2003, 31 (02) : 105 - 110
  • [22] MICROBIAL CONTAMINATION OF DENTAL UNIT WATERLINES IN BUSHEHR, IRAN
    Dobaradaran, Sina
    Nabipour, Iraj
    Ramavandi, Bahman
    Zazouli, Mohammad Ali
    Tahmasebi, Rahim
    Ghaedi, Hossein
    Bahreini, Masoud
    Sirouss, Mehrandokht
    FRESENIUS ENVIRONMENTAL BULLETIN, 2014, 23 (04): : 1000 - 1005
  • [23] Monitoring Dental-Unit-Water-Line Output Water by Current In-office Test Kits
    Lal, Sham
    Singhrao, Sim K.
    Bricknell, Matt
    Pearce, Mark
    Morton, L. H. Glyn
    Ahmed, Waqar
    Crean, St John
    CURRENT MICROBIOLOGY, 2014, 69 (02) : 135 - 142
  • [24] Mycobiology of Dental Unit Water: A Systematic Scoping Review
    Sobon, Norbert
    Fakhruddin, Kausar Sadia
    Samaranayake, Lakshman
    Remmani, Nabiha Belkacem
    Mohammed, Marwan Mansoor
    Porntaveetus, Thantrira
    INTERNATIONAL DENTAL JOURNAL, 2025, 75 (01) : 86 - 99
  • [25] The effect of different types of water sources on dental unit waterline contamination: A systematic review and meta analysis
    Shuai, Ting
    Shao, Tianyi
    Yi, Lijuan
    Han, Shuyu
    Jimenez-Herrera, Maria F.
    Wang, Zhiwen
    Li, Xiue
    HELIYON, 2024, 10 (16)
  • [26] Different Disinfection Strategies in Bacterial and Biofilm Contamination on Dental Unit Waterlines: A Systematic Review
    Li, Chuang
    Xin, Weini
    INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2025,
  • [27] The impact of enhanced cleaning on bacterial contamination of the hospital environmental surfaces: a clinical trial in critical care unit in an Egyptian hospital
    Hamed, Nermine Mahmoud Hassan
    Deif, Osama Ahmed
    El-Zoka, Aleya Hanafy
    Abdel-Atty, Magda Mohamed
    Hussein, Mohamed Fakhry
    ANTIMICROBIAL RESISTANCE AND INFECTION CONTROL, 2024, 13 (01):
  • [28] A Comparison of Different Disinfectants on the Microbiological Quality of Water from the Dental Unit Waterlines of a Military Hospital
    Ma, Mei Siang
    Yunus, Zalini
    Yunus, Ahmad Razi Mohamed
    Ahmad, Zukri
    Fatah, Farizah Abdul
    SAINS MALAYSIANA, 2015, 44 (02): : 187 - 192
  • [29] The importance of biofilm contamination control for dental unit waterlines: a multicenter assessment of the microbiota diversity of biofilm in dental unit waterlines
    Chen, Piaopiao
    Zeng, Jiang
    Hong, Feiruo
    Li, Cong
    Wang, Huimin
    Yu, Xuefen
    JOURNAL OF ORAL MICROBIOLOGY, 2024, 16 (01)
  • [30] Impact of prescribed cleaning and disinfectant use on microbial contamination in the home
    Medrano-Felix, A.
    Martinez, C.
    Campo, N. Castro-del
    Leon-Felix, J.
    Peraza-Garay, F.
    Gerba, C. P.
    Chaidez, C.
    JOURNAL OF APPLIED MICROBIOLOGY, 2011, 110 (02) : 463 - 471