摘要
Microorganisms that have been identified in dental unit waterlines (DUWLs) are of concern because they can cause infections, especially in immunocompromised patients. This study aimed to assess the incidence of microbial contamination in DUWLs before and after intervention to reduce contamination, and to investigate the presence of coliforms, Escherichia coli and Pseudomonas aeruginosa. Water samples were collected aseptically from the waterlines. The high-speed hand-piece and dental chair units were served by one distillation apparatus, which was fed by the potable tap water of four dental clinics. Different interventions were used: chlorination, flushing before clinics and between patients, draining at the end of the day, and freshly distilled water on a daily basis. There was a significant difference between the level of contamination in the high-speed hand-piece (1.5-2.7 log CFU/ml) and dental chair unit water (2.0-3.5 log CFU/ml). Coliforms (0.9%) E. coli (0.9%) and Pseudomonas (1.8%) were detected during 2008. This study indicates the need to monitor water quality regularly and prevent stagnation in DUWLs to reduce the number of viable bacteria to <100 CFU/ml. We recommend flushing the DUWL for 2 min before the first patient and for 10-20 s between patients, flushing the dental unit at the end of the day and draining it overnight to reduce the development of biofilms, and chlorination of the DUWLs.
引用
收藏
页码:647 / 652
页数:6
相关论文
共 50 条
  • [1] Impact of a Risk Management Plan on Legionella Contamination of Dental Unit Water
    Leoni, Erica
    Dallolio, Laura
    Stagni, Francesca
    Sanna, Tiziana
    D'Alessandro, Giovanni
    Piana, Gabriela
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2015, 12 (03): : 2344 - 2358
  • [2] Assessment of nosocomial bacterial contamination in dental unit waterlines: Impact of flushing
    Alkhulaifi, Manal M.
    Alotaibi, Dalal H.
    Alajlan, Hisham
    Binshoail, Thekra
    SAUDI DENTAL JOURNAL, 2020, 32 (02) : 68 - 73
  • [3] Bacterial contamination of water in dental unit reservoirs
    Szymanska, Jolanta
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2007, 14 (01) : 137 - 140
  • [4] Bacterial contamination of dental unit waterlines
    Szymanska, Jolanta
    Sitkowska, Jolanta
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (05) : 3603 - 3611
  • [5] Disinfection methods of dental unit waterlines contamination: a systematic review
    Wu, Mengting
    Shi, Zhiwei
    Yu, Xuefen
    Xu, Yuedan
    Jin, Xinyang
    Zhang, Ling
    Fu, Baiping
    JOURNAL OF MEDICAL MICROBIOLOGY, 2022, 71 (06)
  • [6] Effectiveness and safety of low-concentrated ozonized water for the reduction of contamination in dental unit water lines
    Okubo, Keisuke
    Ito, Takashi
    Shiota, Yasuyoshi
    Kawata, Yusuke
    Yamamoto, Tadashi
    Takashiba, Shogo
    HELIYON, 2019, 5 (08)
  • [7] Impact of Educational Intervention on Cleaning and Disinfection of an Emergency Unit
    dos Santos Oliveira, Bruna Andrade
    Bernardes, Lucas de Oliveira
    Ferreira, Adriano Menis
    Reis Pessalacia, Juliana Dias
    Ribeiro Furlan, Mara Cristina
    Lopes de Sousa, Alvaro Francisco
    de Andrade, Denise
    Barbosa, Dulce Aparecida
    Lapao, Luis Velez
    dos Santos Junior, Aires Garcia
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (09)
  • [8] Control of microbial contamination in dental unit water systems using tetra-sodium EDTA
    Percival, R. S.
    Devine, D. A.
    Nattress, B.
    Kite, P.
    Marsh, P. D.
    JOURNAL OF APPLIED MICROBIOLOGY, 2009, 107 (04) : 1081 - 1088
  • [9] Detection of Bacterial Contamination in Dental Unit Water Lines and Testing the Effectiveness of Disinfectants against these Contaminants
    Lal, Sham
    Kumar, Pardeep
    Sapna
    Parkash, Om
    Malik, Zulfiqar Ali
    Mirbahar, Ameer Ahmed
    Unar, Khalida
    Ghumro, Waheed Ahmed
    Unar, Ayaz Ali
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (08) : 59 - 69
  • [10] Mycological contamination in dental unit waterlines in Istanbul, Turkey
    Kadaifciler, Duygu Goksay
    Okten, Suzan
    Sen, Burhan
    BRAZILIAN JOURNAL OF MICROBIOLOGY, 2013, 44 (03) : 977 - 981