Air curtain applied to fire smoke pollution control

被引:0
|
作者
Gugliermetti, F [1 ]
Santarpia, L [1 ]
Zori, G [1 ]
机构
[1] Univ Roma La Sapienza, Dept Fis Tecn, Rome, Italy
来源
AIR POLLUTION XI | 2003年 / 13卷
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this paper is the evaluation of the smoke flow rate through an opening, separating two spaces, when a fire is developed in one of the two, in order to verify possible control of, reducing oxygenation, fire grow by an air curtain recirculating indoor air. The study relates to a real urban underground railway station, with safe space to allow people to be evacuated, during a fire in the dock. The numerical approach is based on the package FDS (Fire Dynamics Simulator), developed by the NIST centre. The results show that an air curtain can reduce fire oxygenation, but is unable to extinguish fire for oxygen deficiency.
引用
收藏
页码:541 / +
页数:8
相关论文
共 50 条
  • [1] Effectiveness of Smoke Confinement of Air Curtain in Tunnel Fire
    Gao, Dongli
    Li, Tao
    Chen, Zinan
    You, Shuhang
    Wang, Zhongkuan
    Wang, Kaihong
    Lin, Peng
    Mei, Xiujuan
    FIRE TECHNOLOGY, 2020, 56 (05) : 2283 - 2314
  • [2] Effectiveness of Smoke Confinement of Air Curtain in Tunnel Fire
    Dongli Gao
    Tao Li
    Xiujuan Mei
    Zinan Chen
    Shuhang You
    Zhongkuan Wang
    Kaihong Wang
    Peng Lin
    Fire Technology, 2020, 56 : 2283 - 2314
  • [3] Air curtain to control smoke and fire spread in a ventilated multi-floor building
    Safarzadeh, Mohammad
    Heidarinejad, Ghassem
    Pasdarshahri, Hadi
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 159
  • [4] Air curtain as a barrier for smoke in case of fire: Numerical modelling
    Krajewski, G.
    Wegrzynski, W.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2015, 63 (01) : 145 - 153
  • [5] Analysis of air curtain applied in subway station to prevent smoke
    Xie, J
    He, JP
    Zhou, R
    Peng, HP
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 1143 - 1146
  • [6] Numerical simulation on the smoke control effect by air curtain in deep buried metro station fire
    School of Resources and Civil Engineering, Northeastern University, Shenyang 110004, China
    不详
    Dongbei Daxue Xuebao, 2009, SUPPL. (14-17):
  • [7] Winds of fire and smoke: Air pollution and health in the Brazilian Amazon
    Rocha, Rudi
    Sant'Anna, Andre Albuquerque
    WORLD DEVELOPMENT, 2022, 151
  • [8] Optimal control applied to air pollution
    Morel, B
    AIR POLLUTION IN THE URAL MOUNTAINS: ENVIRONMENTAL, HEALTH AND POLICY ASPECTS, 1998, 40 : 307 - 314
  • [9] CRITICAL CONDITIONS FOR FIRE-INDUCED SMOKE CONFINEMENT BY AIR CURTAIN IN LONG CHANNELS
    Ji, Jie
    Zhong, Wei
    Huo, Ran
    Sun, Jinhua
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER, VOL 3, 2009, : 193 - 199
  • [10] Experimental and numerical simulation on smoke control effect and key parameters of Push-pull air curtain in tunnel fire
    Ji, Jingwei
    Lu, Wen
    Li, Fuqing
    Cui, Xiaoting
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 121