Evaluation of protein separations based on hydrophobic interaction chromatography using polyethylene terephthalate capillary-channeled polymer (C-CP) fiber phases

被引:19
|
作者
Wang, Lei [1 ]
Marcus, R. Kenneth [1 ]
机构
[1] Clemson Univ, Dept Chem, Biosyst Res Complex, Clemson, SC 29634 USA
基金
美国国家科学基金会;
关键词
Hydrophobic interaction chromatography; Capillary-channeled polymer fiber; Stationary phase; Proteins; Dynamic binding capacity; PRACTICAL METHOD DEVELOPMENT; STATIONARY PHASES; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODIES; DYNAMIC EVALUATION; BINDING-CAPACITY; PURIFICATION; PERFORMANCE; RETENTION; EXCHANGE;
D O I
10.1016/j.chroma.2018.11.068
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Poly(ethylene terephthalate) (polyester, PET) capillary-channeled polymer fibers are used as the stationary phase for the separation of a synthetic protein mixtures composed of cytochrome c, myoglobin, ribonuclease A, lysozyme, a-chymotrypsinogen A, alpha-chymotrypsin and holo-transferrin. Polyester is a useful phase for HIC, having a mixed alkyl and aromatic backbone to yield mildly hydrophobic properties, an aromatic functionality allowing for pi-pi interactions, and carboxylate end groups adding hydrophilicity. In addition, the lack of extraneous hydrophobic ligands or charged surface species alleviates secondary interactions between proteins and common support phases. Breakthrough experiments with lysozyme solution were operated at various loading flow rates (0.1-0.5 mL min(-1)) and protein concentrations (0.025-1.0 mg mL(-1)), Dynamic binding capacity (DBC) was plotted and results fit to two isotherm models: Langmuir and Freundlich. Column stability and reproducibility were tested via 10 continuous lysozyme load (elution cycles. Organic solvents, acetonitrile and isopropanol, were tested with proportions ranging from 0 to 40% in the elution buffer, aiding protein elution, with the best separation efficiency employing similar to 15-20% organic modifier. Resolution was evaluated at solvent pH values between 5 and 7.5, flow rates ranging from 0.2 to 0.6 mL min(-1)8(-1)) and at gradient slopes between 5 and 16.7% B min(-1). Optimum resolution and fast analysis times were achieved employing a steep gradient using high linear velocities. Finally, a comparison of separation efficiency between a commercial HIC phase (TSKgeI Phenyl-5 P W) and the PET fiber column is presented for a standard, six protein mixture, using optimal operation conditions for each column type. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 171
页数:11
相关论文
共 37 条
  • [31] Microbore polypropylene capillary channeled polymer (C-CP) fiber columns for rapid reversed-phase HPLC of proteins
    Randunu, K. Manoj
    Marcus, R. Kenneth
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (03) : 721 - 729
  • [32] Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format
    Kaylan K. Jackson
    Rhonda R. Powell
    Terri F. Bruce
    R. Kenneth Marcus
    Analytical and Bioanalytical Chemistry, 2020, 412 : 4713 - 4724
  • [33] Capillary-Channeled Polymer (C-CP) Fibers as a Stationary Phase for Sample Clean-Up of Protein Solutions for Matrix-Assisted Laser/Desorption Ionization Mass Spectrometry
    Manard, Benjamin T.
    Marcus, R. Kenneth
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (08) : 1419 - 1423
  • [34] Rapid separation of blood plasma exosomes from low-density lipoproteins via a hydrophobic interaction chromatography method on a polyester capillary-channeled polymer fiber phase
    Huang, Sisi
    Ji, Xiaohui
    Jackson, Kaylan K.
    Lubman, David M.
    Ard, Mary B.
    Bruce, Terri F.
    Marcus, R. Kenneth
    ANALYTICA CHIMICA ACTA, 2021, 1167
  • [35] Head group-functionalized poly(ethyleneglycol)-lipid (PEG-lipid) surface modification for highly selective analyte extractions on capillary-channeled polymer (C-CP) fibers
    Schadock-Hewitt, Abby J.
    Pittman, Jennifer J.
    Christensen, Kenneth A.
    Marcus, R. Kenneth
    ANALYST, 2014, 139 (09) : 2108 - 2113
  • [36] Preparation of a novel weak cation exchange/hydrophobic interaction chromatography dual-function polymer-based stationary phase for protein separation using "thiol-ene click chemistry"
    Yang, Fan
    Bai, Quan
    Zhao, Kailou
    Gao, Dong
    Tian, Lei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (06) : 1721 - 1734
  • [37] Preparation of a novel weak cation exchange/hydrophobic interaction chromatography dual-function polymer-based stationary phase for protein separation using “thiol–ene click chemistry”
    Fan Yang
    Quan Bai
    Kailou Zhao
    Dong Gao
    Lei Tian
    Analytical and Bioanalytical Chemistry, 2015, 407 : 1721 - 1734