Oil-in-Water Monitoring Using Membrane Inlet Mass Spectrometry

被引:31
作者
Brkic, Boris [1 ]
France, Neil [1 ]
Taylor, Stephen [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
关键词
VOLATILE ORGANIC-COMPOUNDS; RECTILINEAR ION-TRAP; HYDROCARBONS; SEAWATER; SAMPLES; SYSTEM; MEMS; AIR; GC;
D O I
10.1021/ac2008042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A membrane inlet mass spectrometry (MIMS) system has been used for detection and analysis of two types of North Sea crude oil. The system was installed on-field on the Flotta Oil Terminal (Orkney, UK). It consisted of a quadrupole mass spectrometer (QMS) connected to the capillary probe with a silicone-based membrane. The produced mass spectra and calibration plots from the MIMS instrument showed the capability to measure levels of individual hydrocarbons within crude oil in seawater. The generated mass spectra from the field tests also showed the ability to distinguish between different types of oil and to determine concentrations of toxic hydrocarbons in oil (e.g., benzene, toluene, and xylene (BTX)). The performance of the instrument at different temperatures of seawater and oil droplet sizes was also investigated. The results showed that the QMS-based MIMS system has a potential to complement existing oil-in-water (OiW) monitors by being able to detect different oil types and specific hydrocarbon concentrations with high accuracy, which are currently not supported in commercially available OiW monitors.
引用
收藏
页码:6230 / 6236
页数:7
相关论文
共 41 条
  • [1] AANENSEN G, 2007, OFFSHORE EUROPE
  • [2] Calibration of an in situ membrane inlet mass spectrometer for measurements of dissolved gases and volatile organics in seawater
    Bell, Ryan J.
    Short, R. Timothy
    Van Amerom, Friso H. W.
    Byrne, Robert H.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (23) : 8123 - 8128
  • [3] Development of Quadrupole Mass Spectrometers Using Rapid Prototyping Technology
    Brkic, Boris
    France, Neil
    Clare, Adam T.
    Sutcliffe, Chris J.
    Chalker, Paul R.
    Taylor, Stephen
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (07) : 1359 - 1365
  • [4] Tracking Hydrocarbon Plume Transport and Biodegradation at Deepwater Horizon
    Camilli, Richard
    Reddy, Christopher M.
    Yoerger, Dana R.
    Van Mooy, Benjamin A. S.
    Jakuba, Michael V.
    Kinsey, James C.
    McIntyre, Cameron P.
    Sylva, Sean P.
    Maloney, James V.
    [J]. SCIENCE, 2010, 330 (6001) : 201 - 204
  • [5] Linear Ion Trap Fabricated Using Rapid Manufacturing Technology
    Clare, Adam T.
    Gao, Liang
    Brkic, Boris
    Chalker, Paul R.
    Taylor, Stephen
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (02) : 317 - 322
  • [6] GC and GC-MS characterization of crude oil transformation in sediments and microbial mat samples after the 1991 oil spill in the Saudi Arabian Gulf coast
    de Oteyza, TG
    Grimalt, JO
    [J]. ENVIRONMENTAL POLLUTION, 2006, 139 (03) : 523 - 531
  • [7] JET SEPARATOR MEMBRANE INTRODUCTION MASS-SPECTROMETRY FOR ONLINE QUANTITATION OF VOLATILE ORGANIC-COMPOUNDS IN AQUEOUS-SOLUTIONS
    DEJARME, LE
    BAUER, SJ
    COOKS, RG
    LAURITSEN, FR
    KOTIAHO, T
    GRAF, T
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) : 935 - 942
  • [8] A DIRECT COMPARISON OF UV FLUORESCENCE AND GC MS DATA OF LIPOPHILIC OPEN-OCEAN SEAWATER EXTRACTS
    EHRHARDT, M
    KNAP, A
    [J]. MARINE CHEMISTRY, 1989, 26 (03) : 179 - 188
  • [9] Miniaturization and geometry optimization of a polymer-based rectilinear ion trap
    Fico, Miriam
    Yu, Meng
    Ouyang, Zheng
    Cooks, R. Graham
    Chappell, William J.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (21) : 8076 - 8082
  • [10] A pulsed photoacoustic instrument for the detection of crude oil concentrations in produced water
    Freeborn, SS
    Hannigan, J
    Greig, F
    Suttie, RA
    MacKenzie, HA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) : 3948 - 3952