Peptide-based electrochemical biosensor for juvenile idiopathic arthritis detection

被引:34
作者
Rodovalho, V. R. [1 ]
Araujo, G. R. [1 ]
Vaz, E. R. [1 ]
Ueira-Vieira, C. [1 ]
Goulart, L. R. [1 ]
Madurro, J. M. [2 ]
Brito-Madurro, A. G. [1 ]
机构
[1] Univ Fed Uberlandia, Inst Genet & Biochem, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Inst Chem, Uberlandia, MG, Brazil
关键词
Biosensor; Mimetic peptide; Diagnosis; Screen-printed electrode; Juvenile idiopathic arthritis; SCREEN-PRINTED ELECTRODE; LABEL-FREE; RHEUMATOID-ARTHRITIS; MOLECULAR-DYNAMICS; CONDUCTING POLYMER; CARBON ELECTRODES; HUMAN SERUM; NANOPARTICLES; ANTIBODIES; DIAGNOSIS;
D O I
10.1016/j.bios.2017.10.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Juvenile idiopathic arthritis (JIA) is a wide group of diseases, characterized by synovial inflammation and joint tissue damage. Due to the delay in the implementation of biomarkers into clinical practice and the association with severe sequels, there is an imperative need for new JIA diagnosis strategies. Electrochemical biosensors based on screen-printed electrodes and peptides are promising alternatives for molecular diagnosis. In this work, a novel biosensor for detecting juvenile idiopathic arthritis (JIA) was developed based on the immobilization of the PRF + 1 mimetic peptide, as recognition biological element, on the surface of screen-printed carbon electrode. This biosensor was able to discriminate the JIA positive and negative serum samples from different individuals using differential pulse voltammetry, presenting limits of detection and quantification in diluted samples of 1:784 (v/v) and 1:235 (v/v), respectively. Evaluation by electrochemical impedance spectroscopy showed Rcr 3 times higher for JIA positive sample than for a pool of human serum samples from healthy individuals. Surface analysis of the biosensor by atomic force microscopy, after contact with JIA positive serum, presented great globular clusters irregularly distributed. The long-term stability of the biosensor was evaluated, remaining functional for over 40 days of storage (after storage at 8 degrees C). Therefore, a simple, miniaturized and selective biosensor was developed, being the first one based on mimetic peptide and screen-printed carbon electrode, aiming at the diagnosis of the juvenile idiopathic arthritis in real serum samples.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 54 条
  • [1] Aptamer-conjugated silver nanoparticles for electrochemical dual-aptamer-based sandwich detection of staphylococcus aureus
    Abbaspour, Abdolkarim
    Norouz-Sarvestani, Fatemeh
    Noon, Abolhassan
    Soltani, Noushin
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 68 : 149 - 155
  • [2] Electrochemical detection of individual single nucleotide polymorphisms using monobase-modified apoferritin-encapsulated nanoparticles
    Abbaspour, Abdolkarim
    Noori, Abolhassan
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 37 (01) : 11 - 18
  • [3] Juvenile arthritis: current concepts in terminology, etiopathogenesis, diagnosis, and management
    Abramowicz, S.
    Kim, S.
    Prahalad, S.
    Chouinard, A. F.
    Kaban, L. B.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (07) : 801 - 812
  • [4] A sensitive diagnostic assay of rheumatoid arthritis using three-dimensional ZnO nanorod structure
    Ahn, Keum-Young
    Kwon, Koochul
    Huh, Junghwan
    Kim, Gyu Tae
    Lee, Eun Bong
    Park, Donghyun
    Lee, Jeewon
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 28 (01) : 378 - 385
  • [5] A novel reactive epitope-based antigen targeted by serum autoantibodies in oligoarticular and polyarticular juvenile idiopathic arthritis and development of an electrochemical biosensor
    Araujo, Galber R.
    Fujimura, Patricia T.
    Vaz, Emilia R.
    Silva, Tamiris A.
    Rodovalho, Vinicius R.
    Britto-Madurro, Ana Graci
    Madurro, Joao M.
    Fonseca, Joao E.
    Silva, Carlos H. M.
    Santos, Paula S.
    Mourao, Ana F.
    Canhao, Helena
    Goulart, Luiz R.
    Goncalves, Joao
    Ueira-Vieira, Carlos
    [J]. IMMUNOBIOLOGY, 2016, 221 (05) : 634 - 640
  • [6] Label free biosensor for sensitive human influenza virus hemagglutinin specific antibody detection using coiled-coil peptide modified microelectrode array based platform
    Arya, Sunil K.
    Kongsuphol, Patthara
    Wong, Chee Chung
    Polla, Lee Joseph
    Park, Mi Kyoung
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 194 : 127 - 133
  • [7] Juvenile Idiopathic Arthritis
    Barut, Kenan
    Adrovic, Amra
    Sahin, Sezgin
    Kasapcopur, Ozgur
    [J]. BALKAN MEDICAL JOURNAL, 2017, 34 (02) : 90 - 101
  • [8] Carboxybetaine Modified Interface for Electrochemical Glycoprofiling of Antibodies Isolated from Human Serum
    Bertok, Tomas
    Sediva, Alena
    Filip, Jaroslav
    Ilcikova, Marketa
    Kasak, Peter
    Velic, Dusan
    Jane, Eduard
    Mravcova, Martina
    Rovensky, Jozef
    Kunzo, Pavol
    Lobotka, Peter
    Smatko, Vasilij
    Vikartovska, Alica
    Tkac, Jan
    [J]. LANGMUIR, 2015, 31 (25) : 7148 - 7157
  • [9] Fabrication of graphene/gold-modified screen-printed electrode for detection of carcinoembryonic antigen
    Chan, K. F.
    Lim, H. N.
    Shams, N.
    Jayabal, S.
    Pandikumar, A.
    Huang, N. M.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 666 - 674
  • [10] Advances in biomarkers for paediatric rheumatic diseases
    Consolaro, Alessandro
    Varnier, Giulia C.
    Martini, Alberto
    Ravelli, Angelo
    [J]. NATURE REVIEWS RHEUMATOLOGY, 2015, 11 (05) : 265 - 275