摘要
The separation of four toxic metal ions (Cr3+, Pb(2+), Hg(2+), Ni(2+)) was achieved by optimizing the composition of the histidine/tartaric acid background electrolyte. An on-column preconcentration technique, viz. field amplified sample injection, was performed to improve the sensitivity. This method afforded an enhancement factor of up to 91 800 fold with the LODs ranging from 0.005 to 2.32 mu g/L, which were well below the maximum contaminant levels set by the United States Environmental Protection Agency. The robustness of this method was demonstrated with its application to the analysis of real samples including tap water, drain water, and reservoir water with recoveries between 90 and 120%.
引用
收藏
页码:1190 / 1194
页数:5
相关论文
共 50 条
  • [1] Separation of enantiomers in capillary electrophoresis with contactless conductivity detection
    Gong, XY
    Kubán, P
    Tanyanyiwa, J
    Hauser, PC
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (02) : 230 - 234
  • [2] Separation and Sensitive Detection of Lanthanides by Capillary Electrophoresis and Contactless Conductivity Detection
    Yelkenci, H. Ecem
    Oztekin, Nevin
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (04) : 465 - 470
  • [3] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567
  • [4] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162
  • [5] Separation of fluoroquinolones in acidic buffer by capillary electrophoresis with contactless conductivity detection
    Yang, Zhongju
    Qin, Weidong
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (27) : 5327 - 5332
  • [6] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [7] Contactless conductivity detection in capillary electrophoresis:: A review
    Kubán, P
    Hauser, PC
    ELECTROANALYSIS, 2004, 16 (24) : 2009 - 2021
  • [8] Considerations on contactless conductivity detection in capillary electrophoresis
    Baltussen, E
    Guijt, RM
    van der Steen, G
    Laugere, F
    Baltussen, S
    van Dedem, GWK
    ELECTROPHORESIS, 2002, 23 (17) : 2888 - 2893
  • [9] Determination of heavy metal ions by microchip capillary electrophoresis coupled with contactless conductivity detection
    Liu, Benyan
    Zhang, Yi
    Mayer, Dirk
    Krause, Hans-Joachim
    Jin, Qinghui
    Zhao, Jianlong
    Offenhaeusser, Andreas
    Xu, Yuansen
    ELECTROPHORESIS, 2012, 33 (08) : 1247 - 1250
  • [10] Capacitively Coupled Contactless Conductivity Detection in Capillary Electrophoresis
    Tan Feng
    Guan Yafeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (02) : 152 - 157