Validated 5-point photonumeric scales for the assessment of the periorbital region

被引:9
作者
Pavicic, Tatjana
Pooth, Rainer [1 ]
Prinz, Valentina [2 ]
Cajkovsky, Mia [2 ]
Green, Jeremy B. [3 ]
Hernandez, Claudia A. [4 ]
Mueller, Daniel S. [2 ]
Sattler, Sonja [5 ]
Klepetko, Heike
Day, Doris
Kerscher, Martina [6 ]
Suwanchinda, Atchima [7 ]
Cotofana, Sebastian [8 ]
Frank, Konstantin [9 ]
Fabi, Sabrina G. [10 ]
机构
[1] ICA Aesthet Nav GmbH, Frankfurt, Germany
[2] Yuvell, Vienna, Austria
[3] Skin Associates South Florida, Skin Res Inst, Coral Gables, FL USA
[4] CH Dermatol, Medellin, Colombia
[5] Rosenpk Clin, Darmstadt, Germany
[6] Univ Hamburg, Div Cosmet Sci, Hamburg, Germany
[7] Mahidol Univ, Ramathibodi Hosp, Fac Med, Dept Med,Div Dermatol, Bangkok, Thailand
[8] Mayo Clin, Coll Med & Sci, Dept Clin Anat Mayo, Rochester, MN USA
[9] Ludwig Maximilian Univ Munich, Dept Hand Plast & Aesthet Surg, Pettenkoferstr 8A, D-80336 Munich, Germany
[10] Cosmet Laser Dermatol, San Diego, CA USA
关键词
crow feet; infraorbital hollowing; periorbital region; scales; ANATOMY; COEFFICIENT; FACE;
D O I
10.1111/jocd.14643
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Objective The objective of this investigation was to create and validate 5-point photonumeric scales for the assessment of dynamic crow's feet, static crow's feet, and infraorbital hollows. Material and methods Three novel 5-point photonumeric scales were created by a medical team. A total of 12 raters from all over the world performed a digital validation, and a total of 5 raters a live validation of the created scale. Results The statistical analysis revealed almost perfect intra-rater and inter-rater reliability in the digital validation of the scales for the assessment of static and dynamic crow's feet as well as infraorbital hollows. In the live validation, both crow's feet scales showed almost perfect intra-rater reliability, while the Croma Infraorbital Hollow Assessment Scale showed substantial intra-rater reliability. Inter-rater reliability was substantial for all three scales in the live validation. All three scales, the Croma Dynamic Crow's Feet Assessment Scale, Croma Static Crow's Feet Assessment Scale, and Croma Infraorbital Hollow Assessment Scale, were validated digitally and in a live setting. Conclusion The created scales to assess infraorbital hollowing, dynamic and static crow's feet have been shown to provide substantial to almost perfect agreement in the digital and live validation and can thus be considered as helpful tools in the clinical and research setting. While technical methods and appliances to assess the degrees of severity of age-dependent features are advancing, validated scales are of great importance due to their ease of use and, as shown by the validations, reliability, and reproducibility.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 24 条
[1]   The Layered Anatomy of the Nose: An Ultrasound-Based Investigation [J].
Alfertshofer, Michael G. ;
Frank, Konstantin ;
Ehrl, Denis ;
Freytag, David L. ;
Moellhoff, Nicholas ;
Gotkin, Robert H. ;
Mardini, Samir ;
Beleznay, Katie ;
Swift, Arthur ;
Cotofana, Sebastian .
AESTHETIC SURGERY JOURNAL, 2022, 42 (04) :349-357
[2]  
American Society for Aesthetic Plastic Surgery, 2018, COSM AESTH SURG NAT
[3]   Soft tissue filler augmentation of the orbicularis retaining ligament to improve the lid-cheek junction [J].
Bernardini, Francesco P. ;
Casabona, Gabriela ;
Alfertshofer, Michael G. ;
Frank, Konstantin ;
Moellhoff, Nicholas ;
Gotkin, Robert H. ;
Davidovic, Kristina ;
Voropai, Daria ;
Valli, Andrea ;
Cotofana, Sebastian .
JOURNAL OF COSMETIC DERMATOLOGY, 2021, 20 (11) :3446-3453
[4]   Sample size requirements for testing and estimating coefficient alpha [J].
Bonett, DG .
JOURNAL OF EDUCATIONAL AND BEHAVIORAL STATISTICS, 2002, 27 (04) :335-340
[5]   Safety and tolerability of onabotulinumtoxinA in the treatment of facial lines: A meta-analysis of individual patient data from global clinical registration studies in 1678 participants [J].
Brin, Mitchell F. ;
Boodhoo, Terry I. ;
Pogoda, Janice M. ;
James, Lynn M. ;
Demos, George ;
Terashima, Yasunori ;
Gu, Juanhong ;
Eadie, Nina ;
Bowen, Beta L. .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2009, 61 (06) :961-970
[6]   Validated Assessment Scales for the Mid Face [J].
Carruthers, Jean ;
Flynn, Timothy C. ;
Geister, Thorin L. ;
Goertelmeyer, Roman ;
Hardas, Bhushan ;
Himmrich, Silvia ;
Jones, Derek ;
Kerscher, Martina ;
De Maio, Mauricio ;
Mohrmann, Cornelia ;
Narins, Rhoda S. ;
Pooth, Rainer ;
Rzany, Berthold ;
Sattler, Gerhard ;
Buchner, Larry ;
Benter, Ursula ;
Breitscheidel, Lusine ;
Carruthers, Alastair .
DERMATOLOGIC SURGERY, 2012, 38 (02) :320-332
[7]   The Bidirectional Movement of the Frontalis Muscle: Introducing the Line of Convergence and Its Potential Clinical Relevance [J].
Cotofana, Sebastian ;
Freytag, David L. ;
Frank, Konstantin ;
Sattler, Sonja ;
Landau, Marina ;
Pavicic, Tatjana ;
Fabi, Sabrina ;
Lachman, Nirusha ;
Hernandez, Claudia A. ;
Green, Jeremy B. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 145 (05) :1155-1162
[8]  
Cotofana S, 2019, J DRUGS DERMATOL, V18, P533
[9]   The Functional Anatomy of the Deep Facial Fat Compartments: A Detailed Imaging-Based Investigation [J].
Cotofana, Sebastian ;
Gotkin, Robert H. ;
Frank, Konstantin ;
Koban, Konstantin C. ;
Targosinski, Stefan ;
Sykes, Jonathan M. ;
Schlager, Markus ;
Schlattau, Alexander ;
Schenck, Thilo L. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2019, 143 (01) :53-63
[10]   The Anatomy of the Aging Face: A Review [J].
Cotofana, Sebastian ;
Fratila, Alina A. M. ;
Schenck, Thilo L. ;
Redka-Swoboda, Wolfgang ;
Zilinsky, Isaac ;
Pavicic, Tatjana .
FACIAL PLASTIC SURGERY, 2016, 32 (03) :253-260