Experimental Investigation and Signal Processing Techniques for Degradation Assessment of XLPE and PVC/B Materials under Thermal Aging

被引:23
作者
Kemari, Y. [1 ]
Mekhaldi, A. [1 ]
Teguar, M. [1 ]
机构
[1] Ecole Natl Polytech Alger, Lab Rech Electrotech, 10 Ave Hassen Badi,BP 182, Algiers 16200, Algeria
关键词
Power cable; insulation; thermal aging; cross-linked polyethylene; polyvinyl chloride; current measurement; discrete Fourier transforms; harmonic distortion; wavelet transforms; diagnosis; CURRENT WAVE-FORMS; LEAKAGE CURRENT; CABLE INSULATION; POLY(VINYL CHLORIDE); POLYMERIC MATERIALS; DISCHARGES; EVOLUTION;
D O I
10.1109/TDEI.2017.006399
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Operating conditions subject power cables insulation to a variety of stresses. Among them, the thermal constraint is considered as one of the most severe factors causing irreversible damage to the electrical insulation. In light of this, accelerated thermal aging experiment was performed on cross-linked polyethylene (XLPE) and Polyvinyl chloride class B (PVC/B) samples. This paper deals with an experimental study based on the measurement of the AC current through the insulation bulk. First, the waveform in addition to the RMS value of the current were analyzed at different aging stages and for five AC applied voltages ranging from 3 to 12 kV. Fast Fourier Transform (FFT) spectral analysis is employed to assess harmonic contents of the current signal and evaluate its total harmonic distortion (THD). Further in-depth analysis was proposed by decomposing the current into several time-frequency bands using the Discrete Wavelet Transform (DWT) method, then Standard deviation-Multi Resolution Analysis (STD-MRA) representation is adopted for the sake of determining the details that correlate with the degradation level of the both studied materials. The obtained results show that our experimental-signal processing techniques methodology could be an efficient diagnostic tool for monitoring the degradation process of insulation materials used in extruded power cables.
引用
收藏
页码:2559 / 2569
页数:11
相关论文
共 33 条
[1]  
[Anonymous], 2010, HIGH VOLTAGE TEST TE
[2]  
[Anonymous], 1991, 60216 IEC
[3]  
[Anonymous], 2004, 502 IEC
[4]  
[Anonymous], 1993, 5191992 IEEE
[5]   Aging of 154 kV underground power cable insulation under combined thermal and electrical stresses [J].
Aras, Faruk ;
Alekperov, Vilayed ;
Can, Nursel ;
Kirkici, Hulya .
IEEE ELECTRICAL INSULATION MAGAZINE, 2007, 23 (05) :25-33
[6]   Thermal stabilisation of poly(vinyl chloride) by organotin compounds [J].
Arkis, E ;
Balköse, D .
POLYMER DEGRADATION AND STABILITY, 2005, 88 (01) :46-51
[7]   Investigation of Accelerated Thermal Aging of EPDM Polymer by Electric Tests in Air and by Means of a SEM Technique in High Vacuum [J].
Bouguedad, D. ;
Jbara, O. ;
Rondot, S. ;
Mekhaldi, A. ;
Hadjadj, A. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (03) :981-989
[8]   Prediction of Mechanical Properties of XLPE Cable Insulation Under Thermal Aging: Neural Network Approach [J].
Boukezzi, Larbi ;
Boubakeur, Ahmed .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) :2125-2134
[9]   Investigations on Leakage Current and Phase Angle Characteristics of Porcelain and Polymeric Insulator under Contaminated Conditions [J].
Chandrasekar, S. ;
Kalaivanan, C. ;
Cavallini, Andrea ;
Montanari, Gian Carlo .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (02) :574-583
[10]   Nonlinear Time Series Analysis of Partial Discharges in Electrical Trees of XLPE Cable Insulation Samples [J].
Chen, Xiangrong ;
Xu, Yang ;
Cao, Xiaolong .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) :1455-1461