Determination of Synthetic Colors in Meat Products Using High-Performance Liquid Chromatography with Photodiode Array Detector

被引:19
|
作者
Pagacikova, D. [1 ]
Lehotay, J. [2 ]
机构
[1] State Vet & Food Inst, Dolny Kubin, Slovakia
[2] Univ Ss Cyril & Methodius, Fac Nat Sci, Dept Chem, SK-91701 Trnava, Slovakia
关键词
synthetic colors; HPLC; trace analysis; meat products; FOOD DYES; QUINOLINE YELLOW; DRINKS; IDENTIFICATION; SEPARATION; BEVERAGES;
D O I
10.1080/10826076.2014.922473
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Synthetic colors are a substance, liquid or powder, which are added to foods to replace natural color lost during processing. A rapid and simple method for simultaneous determination of seven synthetic colors such as amaranth (E123), ponceau 4R (E124), sunset yellow (E110), allura red AC (E129), red 2G (E128), carmoisine (E122), and erythrosine (E127) in meat products using the technique of high-performance liquid chromatography (HPLC) with photodiode array detector is described. The sample is extracted with mixture of methanol and ammonia (80:20v/v) in ultrasonic bath, and then the extract is filtered through a glass filter paper. Synthetic colors were determined by reversed-phase liquid chromatography using a C-18 column and a photodiode array detector. Synthetic colors were separated using HPLC/diode-array detector method on 250x4mm I.D LichroSphere RP-18endcapped column (Merck, Darmstadt, Germany) with 5 mu m C-18 stationary phase, and the chromatograms were detected at 500nm. Acetate buffer (pH 4.8) and acetate buffer (pH 4.8) with acetonitrile (40/60v/v) were used as the mobile phase, and the flow rate was 1.0mLmin(-1). Satisfactory recoveries, ranging from 77.0% (erythrosine) to 99.5% (sunset yellow), were obtained. The method was useful over a wide concentration range of synthetic colors. Synthetic colors as low as 500mgkg(-1) in various meat products could be detected easily without any noticeable disadvantage. The limit of detection and the limit of quantification of individual synthetic dyes were 0.05mgkg(-1) and 0.1mgkg(-1), respectively.
引用
收藏
页码:579 / 583
页数:5
相关论文
共 50 条
  • [1] Determination of 40 synthetic food colors in drinks and candies by high-performance liquid chromatography using a short column with photodiode array detection
    Yoshioka, N.
    Ichihashi, K.
    TALANTA, 2008, 74 (05) : 1408 - 1413
  • [2] Simultaneous determination of synthetic dyes in foodstuffs and beverages by high-performance liquid chromatography coupled with diode-array detector
    Bonan, Stefania
    Fedrizzi, Giorgio
    Menotta, Simonetta
    Elisabetta, Caprai
    DYES AND PIGMENTS, 2013, 99 (01) : 36 - 40
  • [3] A Fast and Validated Method for the Determination of Malondialdehyde in Fish Liver Using High-Performance Liquid Chromatography with a Photodiode Array Detector
    Faizan, Mohammad
    Esatbeyoglu, Tuba
    Bayram, Banu
    Rimbach, Gerald
    JOURNAL OF FOOD SCIENCE, 2014, 79 (04) : C484 - C488
  • [4] Applicability of accelerated solvent extraction for synthetic colorants analysis in meat products with ultrahigh performance liquid chromatography-photodiode array detection
    Liao, Qie Gen
    Li, Wei Hong
    Luo, Lin Guang
    ANALYTICA CHIMICA ACTA, 2012, 716 : 128 - 132
  • [5] EVALUATION OF A PHOTODIODE ARRAY DETECTOR FOR THE VERIFICATION OF PEAK HOMOGENEITY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHAN, HK
    CARR, GP
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (03) : 271 - 277
  • [6] Determination of phenolic acids and rutin in Heliotropium thermophilum by high-performance liquid chromatography with photodiode array detection
    Yildirim, Sercan
    Kadioglu, Asim
    Saglam, Aykut
    Yasar, Ahmet
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2017, 45 (01) : 35 - 48
  • [7] Identification and chemical profiling of monacolins in red yeast rice using high-performance liquid chromatography with photodiode array detector and mass spectrometry
    Li, YG
    Zhang, F
    Wang, ZT
    Hu, ZB
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (05) : 1101 - 1112
  • [8] Simultaneous determination of eperisone hydrochloride and paracetamol in mouse plasma by high performance liquid chromatography-photodiode array detector
    Locatelli, Marcello
    Cifelli, Roberta
    Di Legge, Cristina
    Barbacane, Renato Carmine
    Costa, Nicola
    Fresta, Massimo
    Celia, Christian
    Capolupo, Carlo
    Di Marzio, Luisa
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1388 : 79 - 86
  • [9] Analysis of hydroxylation and nitration products of D-phenylalanine for in vitro and in vivo radical determination using high-performance liquid chromatography and photodiode array detection
    Oeckl, Patrick
    Ferger, Boris
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (14-15): : 1501 - 1508
  • [10] High-performance liquid chromatographic method for the determination of blasticidin S in formulated products with photodiode array detection
    Lo, CC
    Lee, YJ
    Chang, CJ
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (01) : 153 - 158