Cardiothoracic CT Angiography: Current Contrast Medium Delivery Strategies

被引:66
作者
Weininger, Markus [1 ]
Barraza, J. Michael [1 ]
Kemper, Corey A. [2 ]
Kalafut, John F. [2 ]
Costello, Philip [1 ]
Schoepf, U. Joseph [1 ,3 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29401 USA
[2] Medrad, Informat Res, Indianola, PA USA
[3] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29401 USA
关键词
cardiothoracic imaging; contrast enhancement; coronary arteries; CT angiography; pulmonary arteries; CORONARY-ARTERY-DISEASE; ACUTE PULMONARY-EMBOLISM; ROW COMPUTED-TOMOGRAPHY; VENOUS THROMBOEMBOLIC DISEASE; DISPLAY WINDOW SETTINGS; TEST-BOLUS INJECTION; DUAL-SOURCE CT; OF-THE-ART; PATIENT WEIGHT; MULTISLICE CT;
D O I
10.2214/AJR.10.5814
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Over the last decade, rapid technologic evolution in CT has resulted in improved spatial and temporal resolution and acquisition speed, enabling cardiothoracic CT angiography to become a viable and effective noninvasive alternative in the diagnostic algorithm. These new technologic advances have imposed new challenges for the optimization of contrast medium delivery and image acquisition strategies. CONCLUSION. Thorough understanding of contrast medium dynamics is essential for the design of effective acquisition and injection protocols. This article provides an overview of the fundamentals affecting contrast enhancement, emphasizing the modifications to contrast material delivery protocols required to optimize cardiothoracic CT angiography.
引用
收藏
页码:W260 / W272
页数:13
相关论文
共 127 条
[1]   Saline Chasing Technique with Dual-Syringe Injector Systems for Multi-Detector Row Computed Tomographic Angiography: Rationale, Indications, and Protocols [J].
Auler, Mark A. ;
Heagy, Terry ;
Aganovic, Lejla ;
Brothers, Robin ;
Costello, Philip ;
Schoepf, U. Joseph .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2006, 35 (01) :1-11
[2]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[3]   Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Tran, HQ ;
Heiken, JP .
RADIOLOGY, 2000, 216 (03) :872-880
[4]   Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[5]   CT depiction of pulmonary emboli: Display window settings [J].
Bae, KT ;
Mody, GN ;
Balfe, DM ;
Bhalla, S ;
Gierada, DS ;
Gutierrez, FR ;
Menias, CO ;
Woodard, PK ;
Goo, IM ;
Hildebolt, CF .
RADIOLOGY, 2005, 236 (02) :677-684
[6]   Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method [J].
Bae, KT ;
Tran, HQ ;
Heiken, JP .
RADIOLOGY, 2004, 231 (03) :732-736
[7]   Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model [J].
Bae, KT .
RADIOLOGY, 2003, 227 (03) :809-816
[8]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[9]   Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :647-655
[10]   Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity [J].
Bae, Kyongtae T. ;
Seeck, Brian A. ;
Hildebolt, Charles F. ;
Tao, Cheng ;
Zhu, Fang ;
Kanematsu, Masayuki ;
Woodard, Pamela K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :777-784