Spectral analysis of the EBT3 radiochromic film irradiated with 6 MV X-ray radiation

被引:26
作者
Leon-Marroquin, Elsa Y. [1 ,2 ,3 ]
Camacho-Lopez, Miguel A. [1 ]
Garcia-Garduno, Olivia A. [2 ,3 ]
Alfredo Herrera-Gonzalez, J. [2 ,3 ]
Eduardo Villarreal-Barajas, J. [4 ,5 ,6 ]
Gutierrez-Fuentes, Ruben [1 ]
Contreras-Bulnes, Rosalia [7 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Med, Lab Fotomed Biofotan & Espect Laser Pulsos Ultrac, Jesus Carranza y Paseo Tollocan S-N, Toluca 50120, Edo De Mexico, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Fis Media, Mexico City 14269, DF, Mexico
[3] Inst Nacl Neurol & Neurocirug, Unidad Radiocirugia, Mexico City 14269, DF, Mexico
[4] Univ Calgary, Dept Oncol, Calgary, AB TN2 1N4, Canada
[5] Univ Calgary, Dept Phys & Astron, Calgary, AB TN2 1N4, Canada
[6] Torn Baker Canc Ctr, Calgary, AB T2N 4N2, Canada
[7] Univ Autonoma Estado Mexico, Fac Odontol, Jesus Carranza y Paseo Tollocan S-N, Toluca 50120, Mexico
关键词
Absorption spectra; Radiochromic film; Spectrophotometer; DOSE VERIFICATION; DOSIMETRY; PHOTON;
D O I
10.1016/j.radmeas.2016.03.007
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The EBT3 radiochromic film was introduced as the next generation of EBT and EBT2 films, maintaining the composition of the active layer. X-ray radiation produces a change in its visible light absorption spectrum and optical properties being granted make the films suitable for dosimetric applications. The goal of this study is to present results of absorption spectra measurements for the EBT3 radiochromic film exposed to 6 MV X-ray radiation in the dose range from 0 to 50 Gy. Results showed that the spectrum of the EBT3 radiochromic has an intense band centered at around 636 nm and a less intense centered at around 585 nm. Spectral analysis show that in addition to the two main absorption bands, the absorption spectrum in the spectral range from 400 to 700 nm contains nine more absorption bands. Because to the symmetrical structure of the EBT3 radiochromic film, we assume that the additional absorption bands in the spectral range 400-540 nm are due to an interference pattern that is characteristic of a Fabry-Perot cavity. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [41] A study on quality control check of dose distribution in blood bags irradiated by 137Cs source blood irradiator by using EBT3 radiochromic film dosimetry
    Alan, Hatice Yilmaz
    Unal, Gokberk
    Atakul, Tugba
    Akyurek, Serap
    Yucel, Haluk
    RADIATION PHYSICS AND CHEMISTRY, 2024, 214
  • [42] Influence of the Field Size in the Response of the Radiochromic Film EBT3 and Its Impact on the Measurement of the Total Scatter Factors in Small Fields
    Escarcia-Castillo, Fatima
    Amanda Garcia-Garduno, Olivia
    Herrera-Gonzalez, Alfredo
    MEDICAL PHYSICS: Fourteenth Mexican Symposium on Medical Physics, 2016, 1747
  • [43] Measurement of radiotherapy superficial X-ray dose under eye shields with radiochromic film
    Butson, Martin J.
    Cheung, Tsang
    Yu, Peter K. N.
    Price, Sian
    Bailey, Michael
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (01): : 29 - 33
  • [44] Point dose verification of Cranial Stereotactic Radiosurgery using micro Ionization Chamber and EBT3 film for 6MV FF and FFF beams in Varian TrueBeam® LINAC
    Mamballikalam, Gopinath
    Senthilkumar, S.
    Basith, Ahamed P. M.
    Inipully, Rohit
    Jayadevan, P. M.
    Clinto, C. O.
    Bos, Jaon R. C.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (03): : 135 - 142
  • [45] Novel EBT3 film calibration using an integrated HSV color space analysis
    Lertrusdachakul, Intuon
    Lagedamon, Valentin
    Leni, Pierre-Emmanuel
    Gschwind, Regine
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 126
  • [46] Technical Note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV-18 MeV
    Hermida-Lopez, M.
    Luedemann, L.
    Fluehs, A.
    Brualla, L.
    MEDICAL PHYSICS, 2014, 41 (11)
  • [47] EBT3 Radiochromic film response in time-dependent thermal environment and water submersion conditions: Its clinical relevance and uncertainty estimation
    Trivedi, Gaurav
    Singh, Pushpendra P.
    Oinam, Arun S.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 227
  • [48] The influence of a novel transmission detector on 6 MV x-ray beam characteristics
    Venkataraman, Sankar
    Malkoske, Kyle E.
    Jensen, Martin
    Nakonechny, Keith D.
    Asuni, Ganiyu
    McCurdy, Boyd M. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) : 3173 - 3183
  • [49] Selection of gamma analysis acceptance criteria in IMRT QA using Gafchromic EBT3 film dosimetry
    Khan, Muhammad Isa
    Shakil, Muhammad
    Tahir, Muhammad Bilal
    Rafique, Muhammad
    Iqbal, Tahir
    Zahoor, Aliza
    Rehman, Jalil Ur
    Iqbal, Khalid
    Chow, James C. L.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 127 - 131
  • [50] Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams
    Di Lillo, F.
    Mettivier, G.
    Sarno, A.
    Tromba, G.
    Tomic, N.
    Devic, S.
    Russo, P.
    MEDICAL PHYSICS, 2016, 43 (01) : 583 - 588