Spectral analysis of the EBT3 radiochromic film irradiated with 6 MV X-ray radiation

被引:26
|
作者
Leon-Marroquin, Elsa Y. [1 ,2 ,3 ]
Camacho-Lopez, Miguel A. [1 ]
Garcia-Garduno, Olivia A. [2 ,3 ]
Alfredo Herrera-Gonzalez, J. [2 ,3 ]
Eduardo Villarreal-Barajas, J. [4 ,5 ,6 ]
Gutierrez-Fuentes, Ruben [1 ]
Contreras-Bulnes, Rosalia [7 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Med, Lab Fotomed Biofotan & Espect Laser Pulsos Ultrac, Jesus Carranza y Paseo Tollocan S-N, Toluca 50120, Edo De Mexico, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Fis Media, Mexico City 14269, DF, Mexico
[3] Inst Nacl Neurol & Neurocirug, Unidad Radiocirugia, Mexico City 14269, DF, Mexico
[4] Univ Calgary, Dept Oncol, Calgary, AB TN2 1N4, Canada
[5] Univ Calgary, Dept Phys & Astron, Calgary, AB TN2 1N4, Canada
[6] Torn Baker Canc Ctr, Calgary, AB T2N 4N2, Canada
[7] Univ Autonoma Estado Mexico, Fac Odontol, Jesus Carranza y Paseo Tollocan S-N, Toluca 50120, Mexico
关键词
Absorption spectra; Radiochromic film; Spectrophotometer; DOSE VERIFICATION; DOSIMETRY; PHOTON;
D O I
10.1016/j.radmeas.2016.03.007
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The EBT3 radiochromic film was introduced as the next generation of EBT and EBT2 films, maintaining the composition of the active layer. X-ray radiation produces a change in its visible light absorption spectrum and optical properties being granted make the films suitable for dosimetric applications. The goal of this study is to present results of absorption spectra measurements for the EBT3 radiochromic film exposed to 6 MV X-ray radiation in the dose range from 0 to 50 Gy. Results showed that the spectrum of the EBT3 radiochromic has an intense band centered at around 636 nm and a less intense centered at around 585 nm. Spectral analysis show that in addition to the two main absorption bands, the absorption spectrum in the spectral range from 400 to 700 nm contains nine more absorption bands. Because to the symmetrical structure of the EBT3 radiochromic film, we assume that the additional absorption bands in the spectral range 400-540 nm are due to an interference pattern that is characteristic of a Fabry-Perot cavity. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [31] Optical spectral analysis of radiochromic films irradiated with radiation therapy beams
    Darafsheh, Arash
    Zhao, Tianyu
    Khan, Rao
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XIII, 2020, 11231
  • [32] Evaluating dosimetric accuracy of the 6 MV calibration on EBT3 film in the use of Ir-192 high dose rate brachytherapy
    Huang, Lyu
    Gaballa, Hani
    Chang, Jenghwa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [33] Comparison of three film analysis softwares using EBT2 and EBT3 films in radiotherapy
    Pocza, Tamas
    Zongor, Zsuzsanna
    Melles-Bencsik, Barbara
    Zita Tatai-Szabo, Dora
    Major, Tibor
    Pesznyak, Csilla
    RADIOLOGY AND ONCOLOGY, 2020, 54 (04) : 505 - 512
  • [34] Systematic characterization of new EBT4 radiochromic films in clinical x-ray beams
    Khan, Rao
    Rahimi, Robabeh
    Fan, Jiajin
    Chen, Kuan Ling
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2025, 11 (01):
  • [35] Beam quality and dose rate dependency of Gafchromic EBT3 film irradiated with therapeutic megavolt photon beams
    Sharma, Megha
    Singh, Ranjit
    Robert, N.
    Trivedi, G.
    Tomar, P.
    Oinam, A. S.
    RADIATION MEASUREMENTS, 2021, 146
  • [36] Radiochromic film for verification of superficial x-ray backscatter factors
    M. J. Butson
    T. Cheung
    P. K. N. Yu
    Australasian Physics & Engineering Sciences in Medicine, 2007, 30 : 269 - 273
  • [37] Measurement of centi-gray X-ray dose levels with radiochromic film
    Cheung, T
    Yu, PKN
    Butson, MJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1271 - 1273
  • [38] Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
    Ataei, Gholamreza
    Rezaei, Maral
    Gorji, Ebrahimnejad
    Banaei, Amin
    Goushbolagh, Nouraddin Abdi
    Farhood, Bagher
    Bagheri, Mahmoud
    Firouzjah, Razzagh Abedi
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2019, 9 (03): : 204 - 210
  • [39] On the color channel's effect on the dose-response of Gafchromic EBT2 and EBT3 radiochromic films to 6 MeV electron beam
    Al-Sayed, A.
    El Ghazaly, M.
    Hussein, Elham M.
    Kelany, Nermeen A.
    Ibrahim, Manar A.
    Younes, Mahmoud H.
    Abdel-Mageed, M.
    Mohamed, Amal
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [40] Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGER® radiochromic plastic
    Palmer, A. L.
    Di Pietro, P.
    Alobaidli, S.
    Issa, F.
    Doran, S.
    Bradley, D.
    Nisbet, A.
    MEDICAL PHYSICS, 2013, 40 (06)