Spectral analysis of the EBT3 radiochromic film irradiated with 6 MV X-ray radiation

被引:26
|
作者
Leon-Marroquin, Elsa Y. [1 ,2 ,3 ]
Camacho-Lopez, Miguel A. [1 ]
Garcia-Garduno, Olivia A. [2 ,3 ]
Alfredo Herrera-Gonzalez, J. [2 ,3 ]
Eduardo Villarreal-Barajas, J. [4 ,5 ,6 ]
Gutierrez-Fuentes, Ruben [1 ]
Contreras-Bulnes, Rosalia [7 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Med, Lab Fotomed Biofotan & Espect Laser Pulsos Ultrac, Jesus Carranza y Paseo Tollocan S-N, Toluca 50120, Edo De Mexico, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Fis Media, Mexico City 14269, DF, Mexico
[3] Inst Nacl Neurol & Neurocirug, Unidad Radiocirugia, Mexico City 14269, DF, Mexico
[4] Univ Calgary, Dept Oncol, Calgary, AB TN2 1N4, Canada
[5] Univ Calgary, Dept Phys & Astron, Calgary, AB TN2 1N4, Canada
[6] Torn Baker Canc Ctr, Calgary, AB T2N 4N2, Canada
[7] Univ Autonoma Estado Mexico, Fac Odontol, Jesus Carranza y Paseo Tollocan S-N, Toluca 50120, Mexico
关键词
Absorption spectra; Radiochromic film; Spectrophotometer; DOSE VERIFICATION; DOSIMETRY; PHOTON;
D O I
10.1016/j.radmeas.2016.03.007
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The EBT3 radiochromic film was introduced as the next generation of EBT and EBT2 films, maintaining the composition of the active layer. X-ray radiation produces a change in its visible light absorption spectrum and optical properties being granted make the films suitable for dosimetric applications. The goal of this study is to present results of absorption spectra measurements for the EBT3 radiochromic film exposed to 6 MV X-ray radiation in the dose range from 0 to 50 Gy. Results showed that the spectrum of the EBT3 radiochromic has an intense band centered at around 636 nm and a less intense centered at around 585 nm. Spectral analysis show that in addition to the two main absorption bands, the absorption spectrum in the spectral range from 400 to 700 nm contains nine more absorption bands. Because to the symmetrical structure of the EBT3 radiochromic film, we assume that the additional absorption bands in the spectral range 400-540 nm are due to an interference pattern that is characteristic of a Fabry-Perot cavity. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [11] Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams
    Leon-Marroquin, Elsa Y.
    Mulrow, Daniel J.
    Khan, Rao
    Darafsheh, Arash
    MEDICAL PHYSICS, 2019, 46 (02) : 973 - 982
  • [12] Optical Response of Expired EBT3 Film for Absorbed Dose Measurement in X-ray and Electron Beam Range
    Musa, Maisarah
    Abu Mhanna, Hamad Yahia
    Omar, Ahmad Fairuz
    Radzi, Yasmin Md
    Akhdar, Hanan Fawaz
    Ishak, Nor Hafizah
    Al Ewaidat, Haytham
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [13] Absorption spectra response of XRQA radiochromic film to x-ray radiation
    Alnawaf, Hani
    Cheung, Tsang
    Butson, Martin J.
    Yu, Peter K. N.
    RADIATION MEASUREMENTS, 2010, 45 (01) : 129 - 132
  • [14] A study on the use of Gafchromic™ EBT3 film for output factor measurements in kilovoltage X-ray beams
    Gill, Simran
    Hill, Robin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (04) : 465 - 471
  • [15] A study on the use of Gafchromic™ EBT3 film for output factor measurements in kilovoltage X-ray beams
    Simran Gill
    Robin Hill
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 465 - 471
  • [16] EBT3 Films in Low Solar Ultraviolet and X-Ray Dose Measurement: A Comparative Analysis
    Alsaee, Saleh K.
    Omar, Ahmad Fairuz
    Ahmed, Naser M.
    Alsadig, Ahmed
    Sulieman, A.
    Alzimami, Khalid
    DOSE-RESPONSE, 2019, 17 (02):
  • [17] Radiation dose verification of an X-ray based blood irradiator using EBT3 radiochromic films calibrated using Gamma Knife machine
    Soliman, Khaled
    Adili, Marouf
    Alrushoud, Abdullah
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (04) : 369 - 374
  • [18] Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
    Khachonkham, Suphalak
    Dreindl, Ralf
    Heilemann, Gerd
    Lechner, Wolfgang
    Fuchs, Hermann
    Palmans, Hugo
    Georg, Dietmar
    Kuess, Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [19] UNLAMINATED GAFCHROMIC EBT3 FILM FOR ULTRAVIOLET RADIATION MONITORING
    Welch, David
    Randers-Pehrson, Gerhard
    Spotnitz, Henry M.
    Brenner, David J.
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) : 341 - 346
  • [20] Raman scattering for dosimetry using GAFCHROMIC EBT3 radiochromic dosimetry film
    Talarico, Olga S.
    Krylova, Tatyana A.
    Melnik, Nikolay N.
    MEDICAL PHYSICS, 2019, 46 (04) : 1883 - 1887