Misclassification of OSA Severity With Automated Scoring of Home Sleep Recordings

被引:43
作者
Aurora, R. Nisha [1 ]
Swartz, Rachel [1 ]
Punjabi, Naresh M. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Med, Baltimore, MD 21224 USA
[2] Johns Hopkins Univ, Sch Med, Dept Epidemiol, Baltimore, MD 21224 USA
基金
美国国家卫生研究院;
关键词
DIAGNOSTIC-ACCURACY; APNEA; DEVICE; EPIDEMIOLOGY; CHANNEL; POLYSOMNOGRAPHY; TESTS;
D O I
10.1378/chest.14-0929
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The advent of home sleep testing has allowed for the development of an ambulatory care model for OSA that most health-care providers can easily deploy. Although automated algorithms that accompany home sleep monitors can identify and classify disordered breathing events, it is unclear whether manual scoring followed by expert review of home sleep recordings is of any value. Thus, this study examined the agreement between automated and manual scoring of home sleep recordings. METHODS: Two type 3 monitors (ApneaLink Plus [ResMed] and Embletta [Embla Systems]) were examined in distinct study samples. Data from manual and automated scoring were available for 200 subjects. Two thresholds for oxygen desaturation (>= 3% and >= 4%) were used to define disordered breathing events. Agreement between manual and automated scoring was examined using Pearson correlation coefficients and Bland-Altman analyses. RESULTS: Automated scoring consistently underscored disordered breathing events compared with manual scoring for both sleep monitors irrespective of whether a >= 3% or >= 4% oxygen desaturation threshold was used to define the apnea-hypopnea index (AHI). For the ApneaLink Plus monitor, Bland-Altman analyses revealed an average AHI difference between manual and automated scoring of 6.1 (95% CI, 4.9-7.3) and 4.6 (95% CI, 3.5-5.6) events/h for the >= 3% and >= 4% oxygen desaturation thresholds, respectively. Similarly for the Embletta monitor, the average difference between manual and automated scoring was 5.3 (95% CI, 3.2-7.3) and 8.4 (95% CI, 7.2-9.6) events/h, respectively. CONCLUSIONS: Although agreement between automated and manual scoring of home sleep recordings varies based on the device used, modest agreement was observed between the two approaches. However, manual review of home sleep test recordings can decrease the misclassification of OSA severity, particularly for those with mild disease.
引用
收藏
页码:719 / 727
页数:9
相关论文
共 29 条
[1]   Comparison of the automatic analysis versus the manual scoring from ApneaLink™ device for the diagnosis of obstructive sleep apnoea syndrome [J].
Alberto Nigro, Carlos ;
Dibur, Eduardo ;
Aimaretti, Silvia ;
Gonzalez, Sergio ;
Rhodius, Edgardo .
SLEEP AND BREATHING, 2011, 15 (04) :679-686
[2]  
[Anonymous], DEC MEM SLEEP TEST O
[3]   Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea [J].
BaHammam, Ahmed ;
Sharif, Munir ;
Gacuan, Divinagracia E. ;
George, Smitha .
MEDICAL SCIENCE MONITOR, 2011, 17 (02) :MT13-MT19
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea [J].
Calleja, JM ;
Esnaola, S ;
Rubio, R ;
Durán, J .
EUROPEAN RESPIRATORY JOURNAL, 2002, 20 (06) :1505-1510
[6]   Visual and different automatic scoring profiles of respiratory variables in the diagnosis of sleep apnoea-hypopnoea syndrome [J].
Carrasco, O ;
Montserrat, JM ;
Lloberes, P ;
Ascasco, C ;
Ballester, E ;
Fornas, C ;
RodriguezRoisin, R .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (01) :125-130
[7]   Evaluation of a portable recording device (ApneaLink™) for case selection of obstructive sleep apnea [J].
Chen, Hui ;
Lowe, Alan A. ;
Bai, Yuxing ;
Hamilton, Peter ;
Fleetham, John A. ;
Almeida, Fernanda R. .
SLEEP AND BREATHING, 2009, 13 (03) :213-219
[8]  
Collop NA, 2007, J CLIN SLEEP MED, V3, P737
[9]   Evaluation of a Single-Channel Nasal Pressure Device to Assess Obstructive Sleep Apnea Risk in Laboratory and Home Environments [J].
Crowley, Kate E. ;
Rajaratnam, Shantha M. W. ;
Shea, Steven A. ;
Epstein, Lawrence J. ;
Czeisler, Charles A. ;
Lockley, Steven W. .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (02) :109-116
[10]  
Dingli K, 2003, EUR RESP J, V21