Ten-year follow-up of laser in situ keratomileusis for myopia of up to-10 diopters

被引:131
作者
Alio, Jorge L. [1 ,2 ]
Muftuoglu, Orkun [3 ]
Ortiz, Dolores [1 ,2 ]
Perez-Santonja, Juan Jose [1 ,2 ]
Artola, Alberto [1 ,2 ]
Ayala, Maria Jose [1 ,2 ]
Garcia, Maria Jose [1 ,2 ]
De Luna, Gracia Castro [1 ,2 ]
机构
[1] Miguel Hernandez Univ, Sch Med, Inst Oftalmol Alicante, Dept Refract Surg, Alicante 03016, Spain
[2] Miguel Hernandez Univ, Inst Oftalmol Alicante, Div Ophthalmol, Alicante 03016, Spain
[3] Ankara Univ, Sch Med, TR-06100 Ankara, Turkey
关键词
D O I
10.1016/j.ajo.2007.09.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the long-term outcomes of laser in situ keratomileusis (LASIK) for myopia of up to -10 diopters (D). DESIGN: A long-term (10-year) follow,up retrospective, interventional case series. METHODS: The study included 97 eyes of 70 patients with a preoperative spherical equivalent (SE) of up to -10 D treated with myopic LASIK at the Instituto Oftalmologico de Alicante, Alicante, Spain, using the VISX 20/20 excimer laser (Santa Clara, California, USA) and the Automated Corneal Shaper microkeratome (Chiron Vision, Irvine, California, USA). All patients were evaluated three months, one year, two years, five years, and 10 years after surgery. The main outcome measures were refractive predictability and stability, mean corneal keratometry, topographical cylinder, safety, efficacy, stability of visual acuity, and postoperative complications. RESULTS: At 10 years, 71 (73%) of 97 eyes were,within +/- 1.00 D and 89 (92%) were within +/- 2.00 D. Twenty eyes (20.8%) underwent retreatments because of overcorrection, undercorrection, regression, or both. The mean SE slightly decreased (myopic regression) over 10 years, with a mean myopic regression of -0.12 +/- 0.16 D per year. Fifty-four (54.6%) of 97 eyes demonstrated an increase in best spectacle-corrected visual acuity (BSCVA) after 10 years. No eye developed corneal ectasia in the long-term, and only three eyes lost more than two lines of BSCVA because of complications that were not attributable to the LASIK procedure. CONCLUSIONS: LASIK for myopia of up to -10 D is a safe and effective procedure with slight myopic regression that slows down with time and a high rate of BSCVA increase in the long-term.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 32 条
[1]  
Ambrosio Renato Jr, 2003, Semin Ophthalmol, V18, P2, DOI 10.1080/08820530390897738
[2]   MAGNIFICATION AND VISUAL-ACUITY IN REFRACTIVE SURGERY [J].
APPLEGATE, RA ;
HOWLAND, HC .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (10) :1335-1342
[3]  
Binder PS, 2005, J REFRACT SURG, V21, P749
[4]  
Carones F, 1996, Ophthalmic Surg Lasers, V27, pS458
[5]   The association between myopia and various subtypes of lens opacity - SEE (Salisbury Eye Evaluation) project [J].
Chang, MA ;
Congdon, NG ;
Bykhovskaya, I ;
Munoz, B ;
West, SK .
OPHTHALMOLOGY, 2005, 112 (08) :1395-1401
[6]   Regression and its mechanisms after laser in situ keratomileusis in moderate and high myopia [J].
Chayet, AS ;
Assil, KK ;
Montes, M ;
Espinosa-Lagana, M ;
Castellanos, A ;
Tsioulias, G .
OPHTHALMOLOGY, 1998, 105 (07) :1194-1199
[7]   Progressive post-LASIK keratectasia - Biomechanical instability or chronic disease process? [J].
Comaish, IF ;
Lawless, MA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2206-2213
[8]   Photorefractive keratectomy versus laser in situ keratomileusis for moderate to high myopia - A randomized prospective study [J].
Hersh, PS ;
Brint, SF ;
Maloney, RK ;
Durrie, DS ;
Gordon, M ;
Michelson, MA ;
Thompson, VM ;
Berkeley, RB ;
Schein, OD ;
Steinert, RF .
OPHTHALMOLOGY, 1998, 105 (08) :1512-1522
[9]   Laser in situ keratomileusis for moderate and high myopia and myopic astigmatism [J].
Knorz, MC ;
Wiesinger, B ;
Liermann, A ;
Seiberth, V ;
Liesenhoff, H .
OPHTHALMOLOGY, 1998, 105 (05) :932-940
[10]  
Knorz MC, 1996, J REFRACT SURG, V12, P575