Microstrain fields for cortical bone in uniaxial tension: optical analysis method

被引:16
作者
Kim, DG
Brunski, JB
Nicolella, DP
机构
[1] Rensselaer Polytech Inst, Dept Mech Engn, Troy, NY USA
[2] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
[3] SW Res Inst, Mech & Mat Engn Div, San Antonio, TX USA
关键词
bone mechanics; tension; microstrain field; DISMAP; image analysis;
D O I
10.1243/095441105X9291
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study employed an optical strain measurement method, called microdisplacements by machine vision photogrammetry (DISMAP), to measure both the global and local strain fields in microtensile specimens of cortical bone subjected to controlled uniaxial tension. The variation of local maximum principal strains was measured within the gauge region of samples as a function of applied tensile stress during testing. High gradients of local strain appeared around microstructural features in stressed bone even while the global strain for the entire gauge region showed a strong linear correlation with increasing tensile stress (r(2) = 0.98, p < 0.0001). The highest local strain around microstructural features in bone was 11.5-79.5 times higher than the global strain.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 16 条
[1]   MEASUREMENT AND ANALYSIS OF INVIVO BONE STRAINS ON THE CANINE RADIUS AND ULNA [J].
CARTER, DR ;
SMITH, DJ ;
SPENGLER, DM ;
DALY, CH ;
FRANKEL, VH .
JOURNAL OF BIOMECHANICS, 1980, 13 (01) :27-&
[2]  
CURREY JD, 1984, MECH ADAPTATIONS BON, P67
[3]   MEASUREMENT OF MICRODISPLACEMENTS BY MACHINE VISION PHOTOGRAMMETRY (DISMAP) [J].
FRANKE, EA ;
WENZEL, DJ ;
DAVIDSON, DL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (05) :1270-1279
[4]   Early stage stress relaxation in compact bone [J].
Goto, T ;
Sasaki, N ;
Hikichi, K .
JOURNAL OF BIOMECHANICS, 1999, 32 (01) :93-97
[5]  
JOWSEY J, 1977, BONE BIOPSY, P25
[6]  
Kim DG, 2001, THESIS RENSSELAER PO
[7]   Tensile testing of microsamples [J].
LaVan, DA ;
Sharpe, WN .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :210-216
[8]   Surface deformation measurements of a cylindrical specimen by digital image correlation [J].
Lu, H ;
Vendroux, G ;
Knauss, WG .
EXPERIMENTAL MECHANICS, 1997, 37 (04) :433-439
[9]   INCREASED INTRACORTICAL REMODELING FOLLOWING FATIGUE DAMAGE [J].
MORI, S ;
BURR, DB .
BONE, 1993, 14 (02) :103-109
[10]   Machine vision photogrammetry: a technique for measurement of microstructural strain in cortical bone [J].
Nicolella, DP ;
Nicholls, AE ;
Lankford, J ;
Davy, DT .
JOURNAL OF BIOMECHANICS, 2001, 34 (01) :135-139