Simulation study on 3D convolutional neural networks for time-of-flight prediction in monolithic PET detectors using digitized waveforms

被引:13
作者
Maebe, Jens [1 ]
Vandenberghe, Stefaan [1 ]
机构
[1] Univ Ghent, Dept Elect & Informat Syst, Ghent, Belgium
关键词
positron emission tomography; PET; time-of-flight; monolithic scintillation detector; deep learning; convolutional neural network; CNN; RESOLUTION;
D O I
10.1088/1361-6560/ac73d3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. We investigate the use of 3D convolutional neural networks for gamma arrival time estimation in monolithic scintillation detectors. Approach. The required data is obtained by Monte Carlo simulation in GATE v8.2, based on a 50 x 50 x 16 mm(3) monolithic LYSO crystal coupled to an 8 x 8 readout array of silicon photomultipliers (SiPMs). The electronic signals are simulated as a sum of bi-exponentional functions centered around the scintillation photon detection times. We include various effects of statistical fluctuations present in non-ideal SiPMs, such as dark counts and limited photon detection efficiency. The data was simulated for two distinct overvoltages of the SensL J-Series 60 035 SiPMs, in order to test the effects of different SiPM parameters. The neural network uses the array of detector waveforms, digitized at 10 GS s(-1), to predict the time at which the gamma arrived at the crystal. Main results. Best results were achieved for an overvoltage of +6 V, at which point the SiPM reaches its optimal photon detection efficiency, resulting in a coincidence time resolution (CTR) of 141 ps full width at half maximum (FWHM). It is a 26% improvement compared to a simple averaging of the first few SiPM timestamps obtained by leading edge discrimination, which in comparison produced a CTR of 177 ps FWHM. In addition, better detector uniformity was achieved, although some degradation near the corners did remain. Significance. These improvements in time resolution can lead to higher signal-to-noise ratios in time-of-flight positron emission tomography, ultimately resulting in better diagnostic capabilities.
引用
收藏
页数:10
相关论文
共 25 条
[1]   Understanding and simulating SiPMs [J].
Acerbi, Fabio ;
Gundacker, Stefan .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 926 :16-35
[2]   Using convolutional neural networks to estimate time-of-flight from PET detector waveforms [J].
Berg, Eric ;
Cherry, Simon R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
[3]   Advances in coincidence time resolution for PET [J].
Cates, Joshua W. ;
Levin, Craig S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06) :2255-2264
[4]   Artificial neural networks for positioning of gamma interactions in monolithic PET detectors [J].
Decuyper, Milan ;
Stockhoff, Mariele ;
Vandenberghe, Stefaan ;
Van Holen, Roel .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07)
[5]   Evolution of PET Detectors and Event Positioning Algorithms Using Monolithic Scintillation Crystals [J].
Gonzalez-Montoro, Andrea ;
Gonzalez, Antonio J. ;
Pourashraf, Shirin ;
Miyaoka, Robert S. ;
Bruyndonckx, Peter ;
Chinn, Garry ;
Pierce, Larry A., II ;
Levin, Craig S. .
IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (03) :282-305
[6]   Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission [J].
Gundacker, Stefan ;
Turtos, Rosana Martinez ;
Kratochwil, Nicolaus ;
Pots, Rosalinde Hendrika ;
Paganoni, Marco ;
Lecoq, Paul ;
Auffray, Etiennette .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (02)
[7]   Ensemble of neural networks for 3D position estimation in monolithic PET detectors [J].
Iborra, A. ;
Gonzalez, A. J. ;
Gonzalez-Montoro, A. ;
Bousse, A. ;
Visvikis, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19)
[8]   GATE:: a simulation toolkit for PET and SPECT [J].
Jan, S ;
Santin, G ;
Strul, D ;
Staelens, S ;
Assié, K ;
Autret, D ;
Avner, S ;
Barbier, R ;
Bardiès, M ;
Bloomfield, PM ;
Brasse, D ;
Breton, V ;
Bruyndonckx, P ;
Buvat, I ;
Chatziioannou, AF ;
Choi, Y ;
Chung, YH ;
Comtat, C ;
Donnarieix, D ;
Ferrer, L ;
Glick, SJ ;
Groiselle, CJ ;
Guez, D ;
Honore, PF ;
Kerhoas-Cavata, S ;
Kirov, AS ;
Kohli, V ;
Koole, M ;
Krieguer, M ;
van der Laan, DJ ;
Lamare, F ;
Largeron, G ;
Lartizien, C ;
Lazaro, D ;
Maas, MC ;
Maigne, L ;
Mayet, F ;
Melot, F ;
Merheb, C ;
Pennacchio, E ;
Perez, J ;
Pietrzyk, U ;
Rannou, FR ;
Rey, M ;
Schaart, DR ;
Schmidtlein, CR ;
Simon, L ;
Song, TY ;
Vieira, JM ;
Visvikis, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4543-4561
[9]   Performance evaluation of the MOLECUBES β-CUBE-a high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectors [J].
Krishnamoorthy, Srilalan ;
Blankemeyer, Eric ;
Mollet, Pieter ;
Surti, Suleman ;
Van Holen, Roel ;
Karp, Joel S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15)
[10]   Exploring TOF capabilities of PET detector blocks based on large monolithic crystals and analog SiPMs [J].
Lamprou, Efthymios ;
Gonzalez, Antonio J. ;
Sanchez, Filomeno ;
Benlloch, Jose M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 70 :10-18