Reproducibility of heart rate variability and baroreflex sensitivity measurements in children

被引:36
作者
Dietrich, Andrea [1 ]
Rosmalen, Judith G. M. [2 ]
Althaus, Monika [1 ]
van Roon, Arie M. [3 ]
Mulder, Lambertus J. M. [4 ]
Minderaa, Ruud B. [1 ]
Oldehinkel, Albertine J. [2 ,5 ]
Riese, Harriette [2 ,6 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Psychiat Child & Adolescent Psychiat, NL-9700 AR Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Interdisciplinary Ctr Psychiat Epidemiol, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, NL-9700 RB Groningen, Netherlands
[4] Univ Groningen, Dept Expt Psychol, NL-9712 TS Groningen, Netherlands
[5] Sophia Childrens Univ Hosp, Erasmus Med Ctr Rotterdam, Dept Child & Adolescent Psychiat, NL-3015 GJ Rotterdam, Netherlands
[6] Univ Groningen, Univ Med Ctr Groningen, Unit Genet Epidemiol & Bioinformat, NL-9700 RB Groningen, Netherlands
关键词
Cardiac autonomic function; Baroreflex sensitivity; Children; Heart rate variability; Test-retest reliability; Reproducibility; RESPIRATORY SINUS ARRHYTHMIA; STATISTICAL-METHODS; AUTONOMIC FUNCTION; YOUNG-ADULTS; VAGAL TONE; RELIABILITY; REST; EXERCISE; ADOLESCENTS; REACTIVITY;
D O I
10.1016/j.biopsycho.2010.05.005
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Despite their extensive use, the reproducibility of cardiac autonomic measurements in children is not well-known. We investigated the reproducibility of short-term continuous measurements of heart rate (HR), heart rate variability (HRV, time and frequency domain), and spontaneous baroreflex sensitivity (BRS, frequency domain) in the supine and standing position in 57 children (11.2 +/- 0.7 years, 52.6% boys). Reproducibility between two sessions within a two-week interval was evaluated by intraclass correlation coefficients (ICCs), standard error of measurement, coefficients of variation (CVs), limits of agreement, and Bland-Altman plots. HR and HRV were moderately-to-highly (ICC = .63-.79; CV = 5.7%-9.7%) and BRS moderately (ICC = .49-.63; CV = 11.4%-14.0%) reproducible. While the BRS measurements were slightly less reproducible than the HR and HRV measurements, all can be reliably applied in research, thus implicating sufficient capacity to detect real differences between children. Still, clinical studies focusing on individual changes in cardiac autonomic functioning need to address the considerable random variations that may occur between test-retest measurements. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 49 条
[21]   Cohort Profile: The Dutch TRacking Adolescents Individual Lives Survey; TRAILS [J].
Huisman, Martijn ;
Oldehinkel, Albertine J. ;
de Winter, Andrea ;
Minderaa, Ruud B. ;
de Bildt, Annelies ;
Huizink, Anja C. ;
Verhulst, Frank C. ;
Ormel, Johan .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2008, 37 (06) :1227-1235
[22]  
Iellamo F, 1996, J HYPERTENS, V14, P1099
[23]   Baroreflex sensitivity as an individual characteristic feature [J].
Jira, M. ;
Zavodna, E. ;
Honzikova, N. ;
Novakova, Z. ;
Fiser, B. .
PHYSIOLOGICAL RESEARCH, 2006, 55 (03) :349-351
[24]   Reliability of cardiovascular reactivity to stress: Internal consistency [J].
Kelsey, Robert M. ;
Ornduff, Sidney R. ;
Alpert, Bruce S. .
PSYCHOPHYSIOLOGY, 2007, 44 (02) :216-225
[25]   Baroreflex sensitivity: Measurement and clinical implications [J].
La Rovere, Maria Teresa ;
Pinna, Gian Domenico ;
Raczak, Grzegorz .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2008, 13 (02) :191-207
[26]   The effect of experiential anchoring on the reproducibility of exercise regulation in adolescent children [J].
Lamb, KL ;
Eaves, SJ ;
Hartshorn, JEO .
JOURNAL OF SPORTS SCIENCES, 2004, 22 (02) :159-165
[27]   Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study) [J].
Laude, D ;
Elghozi, JL ;
Girard, A ;
Bellard, E ;
Bouhaddi, M ;
Castiglioni, P ;
Cerutti, C ;
Cividjian, A ;
Di Rienzo, M ;
Fortrat, JO ;
Janssen, B ;
Karemaker, JM ;
Lefthériotis, G ;
Parati, G ;
Persson, PB ;
Porta, A ;
Quintin, L ;
Regnard, J ;
Rüdiger, H ;
Stauss, HM .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2004, 286 (01) :R226-R231
[28]   Moderate-term reproducibility of heart rate variability during rest and light to moderate exercise in children [J].
Leicht, A. S. ;
Allen, G. D. .
BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2008, 41 (07) :627-633
[29]   Day-by-day variability of spontaneous baroreflex sensitivity measurements: implications for their reliability in clinical and research applications [J].
Maestri, Roberto ;
Raczak, Grzegorz ;
Torunski, Antoni ;
Sukiennik, Adam ;
Kozlowski, Dariusz ;
La Rovere, Maria Teresa ;
Pinna, Gian Domenico .
JOURNAL OF HYPERTENSION, 2009, 27 (04) :806-812
[30]   Clinical and haemodynamic correlates of heart rate variability in children with congenital heart disease [J].
Massin, M ;
von Bernuth, G .
EUROPEAN JOURNAL OF PEDIATRICS, 1998, 157 (12) :967-971