Lock-in integration for detection of tiny bioimpedance variations

被引:0
作者
Priide, Eiko [1 ]
Annus, Paul [1 ]
Metshein, Margus [1 ]
Land, Raul [1 ]
Martens, Olev [1 ]
Min, Mart [1 ]
机构
[1] Tallinn Univ Technol, Thomas Johann Seebeck Dept Elect, Tallinn, Estonia
来源
2018 16TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC) | 2018年
基金
欧盟地平线“2020”;
关键词
bioimpedance; dynamic range; synchronous measurement; lock-in detection; CENTRAL BLOOD-PRESSURE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is often desirable to detect tiny variations on top of larger static base value. Synchronous or lock-in measurement related problems are discussed in the current paper, and new solution is proposed for detection of bioimpedance variations. Proposed method is believed to be simpler, and more robust compared to known solutions. In the heart of the method is lock in integrator, used as differentiating peak detector. The base component of the signal is rejected, giving better dynamic range for the information carrying variable component of the bioimpedance due to the apparent differentiation. Reduction of the additive off band signals and noise is considered as well.
引用
收藏
页数:4
相关论文
共 16 条
[1]  
Annus P, 2005, PROCEEDINGS OF THE 2005 EUROPEAN CONFERENCE ON CIRCUIT THEORY AND DESIGN, VOL 3, P23
[2]   Quantization of the response signal differences for the electrical bioimpedance measurement [J].
Annus, P. ;
Land, R. ;
Priidel, E. ;
Metshein, M. ;
Min, M. ;
Martens, O. .
EMBEC & NBC 2017, 2018, 65 :290-293
[3]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[4]  
Grimnes S., 2014, BIOIMPEDANCE BIOELEC
[5]  
Hatschek R., 1994, Patent No. [US5309916A, 5309916]
[6]   NONINVASIVE DETERMINATION OF CENTRAL BLOOD-PRESSURE BY IMPEDANCE PLETHYSMOGRAPHY [J].
HERSCOVICI, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (06) :617-625
[7]   Prediction of aortic augmentation index using radial pulse transmission-wave analysis [J].
Lau, EOY ;
Tse, HF ;
Chan, RHW ;
Chen, WH ;
Lee, PY ;
Lee, SWL ;
Chwang, AT ;
Lau, CP .
JOURNAL OF HYPERTENSION, 2006, 24 (04) :723-730
[8]   Precise synchronous detectors with improved dynamic reserve [J].
Märtens, O .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (05) :1046-1049
[9]   Central blood pressure: current evidence and clinical importance [J].
McEniery, Carmel M. ;
Cockcroft, John R. ;
Roman, Mary J. ;
Franklin, Stanley S. ;
Wilkinson, Ian B. .
EUROPEAN HEART JOURNAL, 2014, 35 (26) :1719-+
[10]   Preventing heart disease in the 21st century implications of the pathobiological determinants of atherosclerosis in youth (PDAY) study [J].
McGill, Henry C., Jr. ;
McMahan, Alex ;
Gidding, Samuel S. .
CIRCULATION, 2008, 117 (09) :1216-1227