Protocol conception for safe selection of mechanical ventilation settings for respiratory failure Patients

被引:7
作者
Lee, Jay Wing Wai [1 ]
Chiew, Yeong Shiong [1 ]
Wang, Xin [1 ]
Tan, Chee Pin [1 ]
Nor, Mohd Basri Mat [2 ]
Cove, Matthew E. [3 ]
Damanhuri, Nor Salwa [4 ]
Chase, J. Geoffrey [5 ]
机构
[1] Monash Univ Malaysia, Sch Engn, Subang Jaya, Selangor, Malaysia
[2] Int Islamic Univ Malaysia, Kulliyah Med, Pahang, Malaysia
[3] Natl Univ Hlth Syst, Dept Med, Div Resp & Crit Care Med, Singapore, Singapore
[4] Univ Teknol MARA, Fac Elect Engn, Cawangan Pulau Pinang, George Town, Malaysia
[5] Univ Canterbury, Ctr Bioengn, Christchurch, New Zealand
关键词
Respiratory failure; Mechanical ventilation; Respiratory mechanics; and decision making; END-EXPIRATORY PRESSURE; ACUTE LUNG INJURY; DISTRESS-SYNDROME; CARE; MODEL; ARDS; BEDSIDE; SYSTEM; VOLUME;
D O I
10.1016/j.cmpb.2021.106577
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Mechanical ventilation is the primary form of care provided to respiratory failure patients. Limited guidelines and conflicting results from major clinical trials means selection of mechanical ventilation settings relies heavily on clinician experience and intuition. Determining optimal mechanical ventilation settings is therefore difficult, where non-optimal mechanical ventilation can be deleterious. To overcome these difficulties, this research proposes a model-based method to manage the wide range of possible mechanical ventilation settings, while also considering patient-specific conditions and responses. Methods: This study shows the design and development of the "VENT" protocol, which integrates the single compartment linear lung model with clinical recommendations from landmark studies, to aid clinical decision-making in selecting mechanical ventilation settings. Using retrospective breath data from a cohort of 24 patients, 3,566 and 2,447 clinically implemented VC and PC settings were extracted respectively. Using this data, a VENT protocol application case study and clinical comparison is performed, and the prediction accuracy of the VENT protocol is validated against actual measured outcomes of pressure and volume. Results: The study shows the VENT protocols' potential use in narrowing an overwhelming number of possible mechanical ventilation setting combinations by up to 99.9%. The comparison with retrospective clinical data showed that only 33% and 45% of clinician settings were approved by the VENT protocol. The unapproved settings were mainly due to exceeding clinical recommended settings. When utilising the single compartment model in the VENT protocol for forecasting peak pressures and tidal volumes, median [IQR] prediction error values of 0.75 [0.31 - 1.83] cmH(2)O and 0.55 [0.19 - 1.20] mL/kg were obtained. Conclusions: Comparing the proposed protocol with retrospective clinically implemented settings shows the protocol can prevent harmful mechanical ventilation setting combinations for which clinicians would be otherwise unaware. The VENT protocol warrants a more detailed clinical study to validate its potential usefulness in a clinical setting. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:17
相关论文
共 79 条
  • [1] Akbulut F.P, 2014, BMC MED INFORM DECIS, P14
  • [2] The Injurious Effects of Elevated or Nonelevated Respiratory Rate during Mechanical Ventilation
    Akoumianaki, Evangelia
    Vaporidi, Katerina
    Georgopoulos, Dimitris
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (02) : 149 - 157
  • [3] Driving Pressure and Survival in the Acute Respiratory Distress Syndrome
    Amato, Marcelo B. P.
    Meade, Maureen O.
    Slutsky, Arthur S.
    Brochard, Laurent
    Costa, Eduardo L. V.
    Schoenfeld, David A.
    Stewart, Thomas E.
    Briel, Matthias
    Talmor, Daniel
    Mercat, Alain
    Richard, Jean-Christophe M.
    Carvalho, Carlos R. R.
    Brower, Roy G.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (08) : 747 - 755
  • [4] Guidelines have done more harm than good
    Amerling, Richard
    Winchester, James F.
    Ronco, Claudio
    [J]. BLOOD PURIFICATION, 2008, 26 (01) : 73 - 76
  • [5] Virtual Mechanical Ventilation Protocol - A Model-based Method To determine MV Settings
    Arunachalam, Ganesa Ramachandran
    Chiew, Yeong Shiong
    Tan, Chee Pin
    Ralib, Azrina Mohd
    Nor, Mohd Basri Mat
    [J]. IFAC PAPERSONLINE, 2020, 53 (02): : 16119 - 16124
  • [6] Clinical management of pressure control ventilation: An algorithmic method of patient ventilatory management to address "forgotten but important variables"
    Ashworth, Lonny
    Norisue, Yasuhiro
    Koster, Megan
    Anderson, Jeff
    Takada, Junko
    Ebisu, Hatsuyo
    [J]. JOURNAL OF CRITICAL CARE, 2018, 43 : 169 - 182
  • [7] Bates JHT, 2009, LUNG MECHANICS: AN INVERSE MODELING APPROACH, P1, DOI 10.1017/CBO9780511627156
  • [8] The standard of care of patients with ARDS: ventilatory settings and rescue therapies for refractory hypoxemia
    Bein, Thomas
    Grasso, Salvatore
    Moerer, Onnen
    Quintel, Michael
    Guerin, Claude
    Deja, Maria
    Brondani, Anita
    Mehta, Sangeeta
    [J]. INTENSIVE CARE MEDICINE, 2016, 42 (05) : 699 - 711
  • [9] Static compliance and driving pressure are associated with ICU mortality in intubated COVID-19 ARDS
    Boscolo, Annalisa
    Sella, Nicolo
    Lorenzoni, Giulia
    Pettenuzzo, Tommaso
    Pasin, Laura
    Pretto, Chiara
    Tocco, Martina
    Tamburini, Enrico
    De Cassai, Alessandro
    Rosi, Paolo
    Polati, Enrico
    Donadello, Katia
    Gottin, Leonardo
    De Rosa, Silvia
    Baratto, Fabio
    Toffoletto, Fabio
    Ranieri, V. Marco
    Gregori, Dario
    Navalesi, Paolo
    [J]. CRITICAL CARE, 2021, 25 (01)
  • [10] Bedside Ultrasound Assessment of Positive End-Expiratory Pressure-induced Lung Recruitment
    Bouhemad, Belaid
    Brisson, Helene
    Le-Guen, Morgan
    Arbelot, Charlotte
    Lu, Qin
    Rouby, Jean-Jacques
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 (03) : 341 - 347