Leadless pacemaker implantation after explantation of infected conventional pacemaker systems: A viable solution?

被引:48
作者
Beurskens, Niek E. G. [1 ]
Tjong, Fleur V. Y. [1 ]
Dasselaar, Kosse J. [1 ]
Kuijt, Wichert J. [1 ]
Wilde, Arthur A. M. [1 ]
Knops, Reinoud E. [1 ]
机构
[1] Univ Amsterdam, Amsterdam UMC, Dept Cardiol, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
Conventional pacemaker therapy; Device and lead extraction; Device infection; Leadless pacemaker therapy; Micra transcatheter pacing system; Nanostim leadless cardiac pacemaker; RISK-FACTORS; CARDIOVERTER-DEFIBRILLATORS; PREVENTION; MANAGEMENT; RATES; DIAGNOSIS;
D O I
10.1016/j.hrthm.2018.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Conventional cardiac device infections are increasing in incidence, causing significant morbidity and mortality. Leadless pacemaker (LP) therapy may provide new opportunities for the management of pacemaker (PM) infections as it does not require implantation of transvenous leads and a pectoral pocket. OBJECTIVE We sought to evaluate the effect of early and late LP implantation in patients diagnosed with device infection. METHODS Patients receiving an LP at our center after conventional PM lead extraction due to infection between December 1, 2013 and November 30, 2017 were included. RESULTS A total of 17 patients (mean age 77.4 +/- 7.77 years) underwent LP implantation (ie, 11 with Nanostim Leadless cardiac pacemaker [Abbott, Chicago, IL] and 6 with Micra transcatheter pacing system [Medtronic, Minneapolis, MN]) after successful PM system explantation. In 9 PM-dependent patients, a temporary transvenous pacing system was placed as a bridge to permanent LP implantation. Early LP implantation was performed in 6 patients (<1 week), and in the remaining patients, the LP was placed at a later stage (>1 week). All patients experienced no LP infection during a mean follow-up of 16 +/- 12 months, including 7 patients with a history of recurrent device infections with a mean follow-up of 20 +/- 14 months. CONCLUSION Early and late LP placement after infected conventional pacing system explantation was a viable option in our case series. This therapy may provide an alternative strategy in the management of device infection, if confirmed by subsequent prospective randomized trials, particularly for patients who are PM dependent or have a history of recurrent device infections.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 19 条
[11]   Infected cardiac-implantable electronic devices: prevention, diagnosis, and treatment [J].
Nielsen, Jens Cosedis ;
Gerdes, Jens Christian ;
Varma, Niraj .
EUROPEAN HEART JOURNAL, 2015, 36 (37) :2484-2490
[12]   Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade Procedures Results From the REPLACE Registry [J].
Poole, Jeanne E. ;
Gleva, Marye J. ;
Mela, Theofanie ;
Chung, Mina K. ;
Uslan, Daniel Z. ;
Borge, Richard ;
Gottipaty, Venkateshwar ;
Shinn, Timothy ;
Dan, Dan ;
Feldman, Leon A. ;
Seide, Hanscy ;
Winston, Stuart A. ;
Gallagher, John J. ;
Langberg, Jonathan J. ;
Mitchell, Kevin ;
Holcomb, Richard .
CIRCULATION, 2010, 122 (16) :1553-U43
[13]   Rates of and Factors Associated With Infection in 200 909 Medicare Implantable Cardioverter-Defibrillator Implants Results From the National Cardiovascular Data Registry [J].
Prutkin, Jordan M. ;
Reynolds, Matthew R. ;
Bao, Haikun ;
Curtis, Jeptha P. ;
Al-Khatib, Sana M. ;
Aggarwal, Saurabh ;
Uslan, Daniel Z. .
CIRCULATION, 2014, 130 (13) :1037-1043
[14]   Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker [J].
Reddy, Vivek Y. ;
Exner, Derek V. ;
Cantillon, Daniel J. ;
Doshi, Rahul ;
Bunch, T. Jared ;
Tomassoni, Gery F. ;
Friedman, Paul A. ;
Estes, N. A. Mark, III ;
Ip, John ;
Niazi, Imran ;
Plunkitt, Kenneth ;
Banker, Rajesh ;
Porterfield, James ;
Ip, James E. ;
Dukkipati, Srinivas R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (12) :1125-1135
[15]   A Leadless Intracardiac Transcatheter Pacing System [J].
Reynolds, Dwight ;
Duray, Gabor Z. ;
Omar, Razali ;
Soejima, Kyoko ;
Neuzil, Petr ;
Zhang, Shu ;
Narasimhan, Calambur ;
Steinwender, Clemens ;
Brugada, Josep ;
Lloyd, Michael ;
Roberts, Paul R. ;
Sagi, Venkata ;
Hummel, John ;
Bongiorni, Maria Grazia ;
Knops, Reinoud E. ;
Ellis, Christopher R. ;
Gornick, Charles C. ;
Bernabei, Matthew A. ;
Laager, Verla ;
Stromberg, Kurt ;
Williams, Eric R. ;
Hudnall, J. Harrison ;
Ritter, Philippe .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (06) :533-541
[16]   Guidelines for the diagnosis, prevention and management of implantable cardiac electronic device infection. Report of a joint Working Party project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE) [J].
Sandoe, Jonathan A. T. ;
Barlow, Gavin ;
Chambers, John B. ;
Gammage, Michael ;
Guleri, Achyut ;
Howard, Philip ;
Olson, Ewan ;
Perry, John D. ;
Prendergast, Bernard D. ;
Spry, Michael J. ;
Steeds, Richard P. ;
Tayebjee, Muzahir H. ;
Watkin, Richard .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2015, 70 (02) :325-359
[17]   Mortality and Cost Associated With Cardiovascular Implantable Electronic Device Infections [J].
Sohail, Muhammad R. ;
Henrikson, Charles A. ;
Braid-Forbes, Mary Jo ;
Forbes, Kevin F. ;
Lerner, Daniel J. .
ARCHIVES OF INTERNAL MEDICINE, 2011, 171 (20) :1821-1828
[18]   Risk factors associated with early- versus late-onset implantable cardioverter-defibrillator infections [J].
Sohail, Muhammad R. ;
Hussain, Salwa ;
Le, Katherine Y. ;
Dib, Chadi ;
Lohse, Christine M. ;
Friedman, Paul A. ;
Hayes, David L. ;
Uslan, Daniel Z. ;
Wilson, Walter R. ;
Steckelberg, James M. ;
Baddour, Larry M. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2011, 31 (02) :171-183
[19]   Cardiovascular Implantable Electronic Device Replacement Infections and Prevention: Results from the REPLACE Registry [J].
Uslan, Daniel Z. ;
Gleva, Marye J. ;
Warren, David K. ;
Mela, Theofanie ;
Chung, Mina K. ;
Gottipaty, Venkateshwar ;
Borge, Richard ;
Dan, Dan ;
Shinn, Timothy ;
Mitchell, Kevin ;
Holcomb, Richard G. ;
Poole, Jeanne E. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (01) :81-87