Leadless pacemaker implantation after explantation of infected conventional pacemaker systems: A viable solution?

被引:48
作者
Beurskens, Niek E. G. [1 ]
Tjong, Fleur V. Y. [1 ]
Dasselaar, Kosse J. [1 ]
Kuijt, Wichert J. [1 ]
Wilde, Arthur A. M. [1 ]
Knops, Reinoud E. [1 ]
机构
[1] Univ Amsterdam, Amsterdam UMC, Dept Cardiol, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
Conventional pacemaker therapy; Device and lead extraction; Device infection; Leadless pacemaker therapy; Micra transcatheter pacing system; Nanostim leadless cardiac pacemaker; RISK-FACTORS; CARDIOVERTER-DEFIBRILLATORS; PREVENTION; MANAGEMENT; RATES; DIAGNOSIS;
D O I
10.1016/j.hrthm.2018.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Conventional cardiac device infections are increasing in incidence, causing significant morbidity and mortality. Leadless pacemaker (LP) therapy may provide new opportunities for the management of pacemaker (PM) infections as it does not require implantation of transvenous leads and a pectoral pocket. OBJECTIVE We sought to evaluate the effect of early and late LP implantation in patients diagnosed with device infection. METHODS Patients receiving an LP at our center after conventional PM lead extraction due to infection between December 1, 2013 and November 30, 2017 were included. RESULTS A total of 17 patients (mean age 77.4 +/- 7.77 years) underwent LP implantation (ie, 11 with Nanostim Leadless cardiac pacemaker [Abbott, Chicago, IL] and 6 with Micra transcatheter pacing system [Medtronic, Minneapolis, MN]) after successful PM system explantation. In 9 PM-dependent patients, a temporary transvenous pacing system was placed as a bridge to permanent LP implantation. Early LP implantation was performed in 6 patients (<1 week), and in the remaining patients, the LP was placed at a later stage (>1 week). All patients experienced no LP infection during a mean follow-up of 16 +/- 12 months, including 7 patients with a history of recurrent device infections with a mean follow-up of 20 +/- 14 months. CONCLUSION Early and late LP placement after infected conventional pacing system explantation was a viable option in our case series. This therapy may provide an alternative strategy in the management of device infection, if confirmed by subsequent prospective randomized trials, particularly for patients who are PM dependent or have a history of recurrent device infections.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 19 条
[1]   Infections of Cardiovascular Implantable Electronic Devices [J].
Baddour, Larry M. ;
Cha, Yong-Mei ;
Wilson, Walter R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (09) :842-849
[2]  
Catanchin Andrei, 2007, Heart Lung Circ, V16, P434, DOI 10.1016/j.hlc.2007.02.097
[3]   16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United States 1993 to 2008 [J].
Greenspon, Arnold J. ;
Patel, Jasmine D. ;
Lau, Edmund ;
Ochoa, Jorge A. ;
Frisch, Daniel R. ;
Ho, Reginald T. ;
Pavri, Behzad B. ;
Kurtz, Steven M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (10) :1001-1006
[4]   Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients [J].
Johansen, Jens Brock ;
Jorgensen, Ole Dan ;
Moller, Mogens ;
Arnsbo, Per ;
Mortensen, Peter Thomas ;
Nielsen, Jens Cosedis .
EUROPEAN HEART JOURNAL, 2011, 32 (08) :991-998
[5]   Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators - Results of a large prospective study [J].
Klug, Didier ;
Balde, Mamadou ;
Pavin, Dominique ;
Hidden-Lucet, Francoise ;
Clementy, Jacques ;
Sadoul, Nicolas ;
Rey, Jean Luc ;
Lande, Gilles ;
Lazarus, Arnaud ;
Victor, Jacques ;
Barnay, Claude ;
Grandbastien, Bruno ;
Kacet, Salem .
CIRCULATION, 2007, 116 (12) :1349-1355
[6]   2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction [J].
Kusumoto, Fred M. ;
Schoenfeld, Mark H. ;
Wilkoff, Bruce L. ;
Berul, Charles I. ;
Birgersdotter-Green, Ulrika M. ;
Carrillo, Roger ;
Cha, Yong-Mei ;
Clancy, Jude ;
Deharo, Jean-Claude ;
Ellenbogen, Kenneth A. ;
Exner, Derek ;
Hussein, Ayman A. ;
Kennergren, Charles ;
Krahn, Andrew ;
Lee, Richard ;
Love, Charles J. ;
Madden, Ruth A. ;
Mazzetti, Hector Alfredo ;
Moore, JoEllyn Carol ;
Parsonnet, Jeffrey ;
Patton, Kristen K. ;
Rozner, Marc A. ;
Selzman, Kimberly A. ;
Shoda, Morio ;
Srivathsan, Komandoor ;
Strathmore, Neil F. ;
Swerdlow, Charles D. ;
Tompkins, Christine ;
Wazni, Oussama .
HEART RHYTHM, 2017, 14 (12) :E503-+
[7]   Leadless Cardiac Pacemaker Implantation After Lead Extraction in Patients With Severe Device Infection [J].
Kypta, Alexander ;
Blessberger, Hermann ;
Kammler, Juergen ;
Lambert, Thomas ;
Lichtenauer, Michael ;
Brandstaetter, Walter ;
Gabriel, Michael ;
Steinwender, Clemens .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (09) :1067-1071
[8]   Contemporary management of and outcomes from cardiac device related infections [J].
Margey, Ronan ;
McCann, Hugh ;
Blake, Gavin ;
Keelan, Edward ;
Galvin, Joseph ;
Lynch, Maureen ;
Mahon, Niall ;
Sugrue, Declan ;
O'Neill, James .
EUROPACE, 2010, 12 (01) :64-70
[9]  
McCann Peter, 2007, Indian Pacing Electrophysiol J, V7, P40
[10]   Device-Related Infection Among Patients With Pacemakers and Implantable Defibrillators: Incidence, Risk Factors, and Consequences [J].
Nery, Pablo B. ;
Fernandes, Russell ;
Nair, Girish M. ;
Sumner, Glen L. ;
Ribas, Carlos S. ;
Menon, Syamkumar M. Divakara ;
Wang, Xiaoyin ;
Krahn, Andrew D. ;
Morillo, Carlos A. ;
Connolly, Stuart J. ;
Healey, Jeff S. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (07) :786-790