Evaluation of the performance of modern X-ray fluorescence spectrometry systems for the forensic analysis of glass

被引:8
作者
Corzo, Ruthmara [1 ]
Ernst, Troy [2 ]
Insana, Joseph [3 ]
Martinez-Lopez, Claudia [4 ]
Webb, Jodi [5 ]
Haase, Emily [5 ]
Weis, Peter [6 ]
Trejos, Tatiana [4 ]
机构
[1] NIST, Gaithersburg, MD USA
[2] Michigan State Police, Grand Rapids Forens Lab, Grand Rapids, MI USA
[3] Microtrace LLC, Elgin, IL USA
[4] West Virginia Univ, Morgantown, WV 26506 USA
[5] Fed Bur Invest, Quantico, VA USA
[6] Bundeskriminalamt, Wiesbaden, Germany
关键词
Glass; Interlaboratory study; XRF; Silicon drift detector (SDD); INDUCED BREAKDOWN SPECTROSCOPY; PLASMA-MASS SPECTROMETRY; LA-ICP-MS; REFRACTIVE-INDEX; DISCRIMINATION; FRAGMENTS;
D O I
10.1016/j.forc.2022.100447
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Micro X-ray Fluorescence Spectrometry (mu XRF) is a well-established technique for the elemental analysis of glass in forensic casework. The standard test method for the forensic analysis of glass using mu XRF (ASTM E2926) provides recommendations for the number of replicate measurements that should be collected to characterize a known source and the criteria for the comparison between the known and questioned samples. However, these recommendations were based on interlaboratory data collected using mu XRF instrumentation equipped with traditional lithium-doped silicon (SiLi) detectors. This interlaboratory study aimed to evaluate the performance of modern mu XRF systems equipped with silicon drift detectors (SDDs) for the forensic comparison of glass. While the SDD-mu XRF instruments resulted in improved precision and detection limits (1.4 mu g.g(-1)-1386 mu g.g(-1)) and excellent discrimination (>99 %) of different-source samples, the false exclusion rates for same-source samples were relatively high (>20 %). Two methods were evaluated to reduce the high false exclusion rates: increasing the number of fragments collected for the known source and modifying the recommended comparison criteria. To reduce the false exclusion rate to 5 % or less, a minimum of five known fragments were needed. Alternatively, modifying the recommended comparison criterion reduced the false exclusion rate from 23 % to 2 %, while maintaining low false inclusions (<1%). The findings in this study demonstrate the improved sensitivity and precision observed in glass measurements acquired with mu XRF-SDD systems. However, these systems may require adjustments to sampling and the comparison criteria to minimize potential error rates in the forensic comparison of glass fragments.
引用
收藏
页数:11
相关论文
共 22 条
[1]   Interpretation of chemical data from glass analysis for forensic purposes [J].
Akmeemana, Anuradha ;
Weis, Peter ;
Corzo, Ruthmara ;
Ramos, Daniel ;
Zoon, Peter ;
Trejos, Tatiana ;
Ernst, Troy ;
Pollock, Chip ;
Bakowska, Ela ;
Neumann, Cedric ;
Almirall, Jose .
JOURNAL OF CHEMOMETRICS, 2021, 35 (01)
[2]  
[Anonymous], 2016, ASTMStandard E2927-16e1, in ASTM Volume 14.02
[3]  
[Anonymous], 2017, E292617 ASTM
[4]   Forensic comparative glass analysis by laser-induced breakdown spectroscopy [J].
Bridge, Candice M. ;
Powell, Joseph ;
Steele, Katie L. ;
Sigman, Michael E. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (12) :1419-1425
[5]   Characterization of automobile float glass with laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry [J].
Bridge, Candice M. ;
Powell, Joseph ;
Steele, Katie L. ;
Williams, Mary ;
MacInnis, Jean M. ;
Sigman, Michael E. .
APPLIED SPECTROSCOPY, 2006, 60 (10) :1181-1187
[6]   ELEMENTAL ANALYSIS OF SMALL GLASS FRAGMENTS IN FORENSIC-SCIENCE [J].
BUSCAGLIA, JA .
ANALYTICA CHIMICA ACTA, 1994, 288 (1-2) :17-24
[7]   An interlaboratory study evaluating the interpretation of forensic glass evidence using refractive index measurements and elemental composition [J].
Corzo, Ruthmara ;
Hoffman, Tricia ;
Ernst, Troy ;
Trejos, Tatiana ;
Berman, Ted ;
Coulson, Sally ;
Weis, Peter ;
Stryjnik, Aleksandra ;
Dorn, Hendrik ;
Pollock, Edward Chip ;
Workman, Michael Scott ;
Jones, Patrick ;
Nytes, Brendan ;
Scholz, Thomas ;
Xie, Huifang ;
Igowsky, Katherine ;
Nelson, Randall ;
Gates, Kris ;
Gonzalez, Jhanis ;
Voss, Lisa-Mareen ;
Almirall, Jose .
FORENSIC CHEMISTRY, 2021, 22
[8]   The use of LA-ICP-MS databases to calculate analysis of glass evidence [J].
Corzo, Ruthmara ;
Hoffman, Tricia ;
Weis, Peter ;
Franco-Pedroso, Javier ;
Ramos, Daniel ;
Almirall, Jose .
TALANTA, 2018, 186 :655-661
[9]   Assessment and forensic application of laser-induced breakdown spectroscopy (LIBS) for the discrimination of Australian window glass [J].
El-Deftar, Moteaa M. ;
Speers, Naomi ;
Eggins, Stephen ;
Foster, Simon ;
Robertson, James ;
Lennard, Chris .
FORENSIC SCIENCE INTERNATIONAL, 2014, 241 :46-54
[10]   Signal-to-noise ratios in forensic glass analysis by micro X-ray fluorescence spectrometry [J].
Ernst, T. ;
Berman, T. ;
Buscaglia, J. ;
Eckert-Lumsdon, T. ;
Hanlon, C. ;
Olsson, K. ;
Palenik, C. ;
Ryland, S. ;
Trejos, T. ;
Valadez, M. ;
Almirall, J. R. .
X-RAY SPECTROMETRY, 2014, 43 (01) :13-21