Understanding Partial Discharge Activity in Transformer Oil due to Particle Movement under High Frequency AC Voltage Adopting UHF Technique

被引:0
|
作者
Archana, M. [1 ]
Kalpana, B. [2 ]
Sarathi, R. [2 ]
机构
[1] Indian Inst Technol, Dept Appl Mech, Madras 600036, Tamil Nadu, India
[2] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
来源
PROCEEDINGS OF 2011 INTERNATIONAL CONFERENCE ON ELECTRICAL INSULATING MATERIALS (ISEIM) | 2011年
关键词
Partial discharges; UHF sensors; Transformer oil; frequency;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A methodical experimental study was carried out to understand the partial discharges initiated due to particle movement in transformer oil under different frequencies of the AC voltage, by adopting UHF technique. The rise time of the partial discharge current pulse formed due to particle movement is 2ns. It is observed that the frequency content of the signal radiated due to partial discharges generated due o particle movement in the electrode gap lies in the UHF signal range, with its dominant frequency at near 1 GHz, irrespective of frequency of the supply voltage. The UHF signal magnitude and the time required for 100 UHF signals to form shows direct correlation. When the applied voltage is increased above levitation voltage, the UHF signal magnitude formed due to particle movement increases, irrespective of supply voltage frequency. Ternary diagram clearly indicates that irrespective of frequency of the supply voltage, the UHF signal location in the ternary diagram is the same.