BABAR CsI calorimeter design and first beam test results

被引:0
|
作者
Brose, J
机构
[1] Inst. fur Kern- und Teilchenphysik, Technische Universität Dresden
关键词
D O I
10.1016/0168-9002(96)00684-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The BABAR detector at the PEP-II B-factory at SLAC is designed to measure CP violation in the decays of B mesons. In order to meet the physics aims of the experiment the target energy resolution for photons at a polar angle of 90 degrees is: sigma(E)/E = (1%/(4) root/E[GeV]) + 1.2%. This requires a minimum equivalent noise energy of about 150 keV per crystal. using two 1 x 2 cm(2) photodiodes for direct readout of full-size crystals a photoelectron yield of about 8000 e(-)/MeV and equivalent noise energies below 100 keV were obtained in the laboratory. A first beam test using a 5 x 5 array of crystals was performed in the fall of 1995 at an electron/pion beam at PSI. Data were collected at different energies between 100 MeV and 400 MeV allowing the determination of energy and angular resolution as a function of energy, impact position and angle of incidence, Results of a first analysis of these data are presented.
引用
收藏
页码:495 / 498
页数:4
相关论文
共 50 条
  • [41] Results of 2007 test beam of AMS-02 Electromagnetic Calorimeter
    Di Falco, Stefano
    ADVANCES IN SPACE RESEARCH, 2010, 45 (01) : 112 - 122
  • [42] Test-beam results of a prototype position sensitive towerless calorimeter
    Bagdasarov, S
    Goulianos, K
    Maghakian, A
    Wang, QF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 372 (1-2) : 117 - 124
  • [43] First results from pion beam test of an iron/gas calorimeter based on ceramic parallel plate chambers
    Bencze, Gy.L.
    Bizetti, A.
    Civinini, C.
    Dalla Santa, F.
    D'Alessandro, R.
    Ferrando, A.
    Fouz, M.C.
    Iglesias, A.
    Ivochkin, V.
    Josa, M.I.
    Khan, A.
    Malinin, A.
    Martinez-Laso, L.
    Meschini, M.
    Pojidaev, V.
    Salicio, J.M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 386 (2-3): : 259 - 268
  • [44] Test beam results on the proton Zero Degree Calorimeter for the ALICE experiment
    Arnaldi, R.
    Chiavassa, E.
    Cicalo, C.
    Cortese, P.
    De Falco, A.
    Dellacasa, G.
    De Marco, N.
    Ferretti, A.
    Floris, M.
    Gagliardi, M.
    Gallio, M.
    Gemme, R.
    Masoni, A.
    Mereu, P.
    Musso, A.
    Oppedisano, C.
    Piccotti, A.
    Poggio, F.
    Puddu, G.
    Scomparin, E.
    Serci, S.
    Siddi, E.
    Stocco, D.
    Usai, G.
    Vercellin, E.
    Yermia, F.
    CALORIMETRY IN HIGH ENERGY PHYSICS, 2006, 867 : 415 - +
  • [45] Multi bundle shashlik calorimeter prototypes beam-test results
    Nucl Instrum Methods Phys Res Sect A, 2-3 (328):
  • [46] Design and test of the Mu2e undoped CsI plus SiPM crystal calorimeter
    Atanov, N.
    Baranov, V
    Budagov, J.
    Caiulo, D.
    Cervelli, F.
    Colao, F.
    Cordelli, M.
    Corradi, M.
    Davydov, Yu, I
    Di Falco, S.
    Diociaiuti, E.
    Donati, S.
    Donghia, R.
    Echenard, B.
    Giovannella, S.
    Glagolev, V
    Grancagnolo, F.
    Happacher, F.
    Hitlin, D.
    Martini, M.
    Miscetti, S.
    Miyashita, T.
    Morescalchi, L.
    Murat, P.
    Pedreschi, E.
    Pezzullo, G.
    Porter, F.
    Raffaelli, F.
    Ricci, M.
    Saputi, A.
    Sarra, I
    Spinella, F.
    Tassielli, G.
    Tereshchenko, V
    Usubov, Z.
    Vasilyev, I. I.
    Zhu, R. Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 94 - 97
  • [47] Optimization in the design of BES III CsI crystal calorimeter
    Liu, CX
    Fu, CD
    Zhou, L
    Zhang, QJ
    Xia, XM
    Lai, YF
    Li, J
    Fang, J
    Chen, Y
    Cai, X
    Shang, L
    Wang, M
    Lü, JG
    Wang, YF
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 (12): : 1114 - 1118
  • [48] RESULTS FROM A CSI(TL) TEST CALORIMETER WITH PHOTODIODE READOUT BETWEEN 1 GEV AND 20 GEV
    GRASSMANN, H
    LORENZ, E
    MOSER, HG
    VOGEL, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 235 (02) : 319 - 325
  • [49] RESULTS FROM A CsI(Tl) TEST CALORIMETER WITH PHOTODIODE READOUT BETWEEN 1 AND 2 Gev.
    Grassmann, H.
    Lorenz, E.
    Moser, H.G.
    Vogel, H.
    Nuclear instruments and methods in physics research, 1984, A235 (02): : 319 - 325
  • [50] First beam test results of the FORTIS sensor
    Velthuis, J. J.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1017 - 1020