Design of a fatty plaque phantom for validation of strain imaging

被引:4
作者
Boekhoven, R. W. [1 ]
Rutten, M. C. M. [1 ]
van de Vosse, F. N. [1 ]
Lopata, R. G. P. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
来源
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2014年
关键词
ARTERIES;
D O I
10.1109/ULTSYM.2014.0654
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Prior to clinical application of novel techniques such as vascular elastography and photo acoustic imaging, validation studies are of great importance. Gelatin, agar and polyvinyl-alcohol (PVA) phantoms are commonly used. However, more realistic phantoms are needed with complex geometry and different constituents with known properties. For this purpose, a fatty plaque phantom (fPP) was designed. A 15 weight percent (wt%) PVA solution was made, and 1 wt% of silica scatters were added (3 8 nm). The solution was poured in to a custom made mold, acquiring the fPP in four freeze/thaw cycles. B-mode data were acquired using a MyLab70 (Esaote, NL), while being pressurized from 0-80 mmHg. The phantom was imaged using a 3D echo-CT strain imaging method [1], [2], to determine 3D geometry, distension and radial strains. In accordance with the distension data, higher radial strains were found at the lipid inclusion location. In future work, strain data will be compared to numerical models that match the phantoms and experimental conditions to validate the strains measured. Additional stiffening of the PVA using a coagulation bath will be explored, by doing so, increasing the systolic pressure allowed.
引用
收藏
页码:2619 / 2622
页数:4
相关论文
共 50 条
[31]   A Feasibility Study of Ultrasound B-Mode and Strain Imaging for Risk Assessment of Carotid Atherosclerotic Plaques Validated by Magnetic Resonance Imaging [J].
Luo, Jianwen ;
Pan, Xiaochang ;
Huang, Lingyun ;
Tao, Shengzhen ;
Huang, Manwei ;
Zhao, Xihai ;
He, Le ;
Yuan, Chun ;
Bai, Jing .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :561-564
[32]   Vasa Vasorum and Plaque Neovascularization on Contrast-Enhanced Carotid Ultrasound Imaging Correlates With Cardiovascular Disease and Past Cardiovascular Events [J].
Staub, Daniel ;
Patel, Mita B. ;
Tibrewala, Anjan ;
Ludden, David ;
Johnson, Mahala ;
Espinosa, Paul ;
Coll, Blai ;
Jaeger, Kurt A. ;
Feinstein, Steven B. .
STROKE, 2010, 41 (01) :41-47
[33]   Reproducibility of in Vivo Constitutive Parameter Identification Based on 4D Ultrasound Strain Imaging [J].
Wittek, Andreas ;
Fritzen, Claus-Peter ;
Huss, Armin ;
Blase, Christopher .
COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING II, 2023, 38 :153-169
[34]   Reproducibility of computed tomography angiography data analysis using semiautomated plaque quantification software: implications for the design of longitudinal studies [J].
Papadopoulou, Stella-Lida ;
Garcia-Garcia, Hector M. ;
Rossi, Alexia ;
Girasis, Chrysafios ;
Dharampal, Anoeshka S. ;
Kitslaar, Pieter H. ;
Krestin, Gabriel P. ;
de Feyter, Pim J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) :1095-1104
[35]   Impact of residual stress on coronary plaque stress/strain calculations using optical coherence tomography image-based multi-layer models [J].
Huang, Mengde ;
Maehara, Akiko ;
Tang, Dalin ;
Zhu, Jian ;
Wang, Liang ;
Lv, Rui ;
Zhu, Yanwen ;
Zhang, Xiaoguo ;
Zhao, Chen ;
Jia, Haibo ;
Mintz, Gary S. .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
[36]   Lumen enhancement influences absolute noncalcific plaque density on multislice computed tomography coronary angiography: ex-vivo validation and in-vivo demonstration [J].
Cademartiri, Filippo ;
Runza, Giuseppe ;
Palumbo, Alessandro ;
Maffei, Erica ;
Martini, Chiara ;
McFadden, Eugene ;
Somers, Pamela ;
Knaapen, Michiel ;
Verheye, Stefan ;
Weustink, Annick C. ;
Mollet, Nico R. ;
de Feyter, Pim J. ;
Hamers, Ronald ;
Bruining, Nico .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2010, 11 (05) :337-344
[37]   Validation of volume flow measurements with cine phase-contrast MR imaging for peripheral arterial waveforms [J].
McCauley, TR ;
Pena, CS ;
Holland, CK ;
Price, TB ;
Gore, JC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06) :663-668
[38]   Detection of coronary plaques using MR coronary vessel wall imaging: validation of findings with intravascular ultrasound [J].
Gerretsen, Suzanne ;
Kessels, Alfons G. ;
Nelemans, Patty J. ;
Dijkstra, Jouke ;
Reiber, Johan H. C. ;
van der Geest, Rob J. ;
Katoh, Marcus ;
Waltenberger, Johannes ;
van Engelshoven, Jos M. A. ;
Botnar, Rene M. ;
Kooi, M. Eline ;
Leiner, Tim .
EUROPEAN RADIOLOGY, 2013, 23 (01) :115-124
[39]   Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire [J].
Machida, Haruhiko ;
Komori, Yoshiaki ;
Ueno, Eiko ;
Shen, Yun ;
Hirata, Masami ;
Kojima, Shinya ;
Sato, Munekuni ;
Okazaki, Takeshi ;
Masukawa, Ai ;
Morita, Satoru ;
Suzuki, Kazufumi .
JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (08) :571-577
[40]   Quantifying Patient-Specific in vivo Coronary Plaque Material Properties for Accurate Stress/Strain Calculations: An IVUS-Based Multi-Patient Study [J].
Wang, Liang ;
Zhu, Jian ;
Maehara, Akiko ;
Lv, Rui ;
Qu, Yangyang ;
Zhang, Xiaoguo ;
Guo, Xiaoya ;
Billiar, Kristen L. ;
Chen, Lijuan ;
Ma, Genshan ;
Mintz, Gary S. ;
Tang, Dalin .
FRONTIERS IN PHYSIOLOGY, 2021, 12