Long-term Aged Performances of Stator Insulation for Wind Turbine Generator under Repeat Pulse Voltage

被引:0
|
作者
Liu Xuezhong [1 ]
Zhao Xiang [2 ]
Wang Ying [1 ]
Chen Xiaocong [1 ]
Li Dandan [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[2] Goldwind Sci & Technol Co Ltd, Beijing, Peoples R China
关键词
wind turbine generator; stator insulation; electric ageing; repeat pulse; megawatt;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The power inverter between the wind turbine generator and electrical grid is commonly used for adjusting or converting the generator frequency and voltage to the grid. The stator or rotor insulation of generator will endure the step repeat pulse voltages. It has become important to evaluate the stator insulation of wind turbine generator under repeat pulse voltages. Firstly, the lab test setup with the repeat-pulsed voltage up to 10kV and frequency up to 20kHz was established, and the full sized specimens of stator insulation for megawatt direct-driven permanent magnet generator were prepared in this paper. Under the different applied voltage, from 4kV to 6.5kV, the electrical ageing or voltage-endurance testing of specimens at a constant temperature were carried out. The ageing duration was from 100hrs to 5000 hrs. During the ageing process, the ageing characteristic parameters of stator specimen were measured periodically, which included the dissipation factor, capacitance, insulation resistance, partial discharge inception voltage and corona discharge inception voltage. The relationships between the ageing characteristic parameters and ageing duration have been obtained, and the residual breakdown voltage of specimen was taken also. Some of aged specimens, if failed, were examined by means of dissection in the area around the insulation puncture in order to identify the failure location and its cause. Some of un-failed specimens were also dissected for the further analysis like as Fourier transform infrared spectroscopy and microscopy.
引用
收藏
页码:105 / 108
页数:4
相关论文
共 50 条
  • [1] Effects of Accelerated Repetitive Impulse Voltage Aging on Performance of Model Stator Insulation of Wind Turbine Generator
    Liu, Xuezhong
    Zhang, Tianlong
    Bai, Yonggang
    Ding, Xiaoxia
    Wang, Ying
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) : 1606 - 1615
  • [2] The Effect of the Marine Environment on the Stator Insulation System of an Offshore Wind Turbine Generator
    Liu, Xuezhong
    Zhang, Tianlong
    Zhang, Rui
    Bai, Yonggang
    Ding, Xiaoxia
    Zhao, Dan
    Wang, Chenxing
    Wang, Fangwen
    Chen, Tangze
    IEEE ELECTRICAL INSULATION MAGAZINE, 2015, 31 (03) : 10 - 17
  • [3] Condition Evaluation of Stator Winding Insulation of Vintage High Voltage Turbine Generator
    Kumar, P. G. S.
    Reddy, K. Malla
    2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES, 2015,
  • [4] Electrical Tree Propagation in Composite Insulation for Wind Turbine Generator Under Repetitive Impulse Voltage
    Zhang, Rui
    Liu, Xuezhong
    Zhang, Tianlong
    Xue, Changzhi
    Chen, Hongsheng
    Li, Yanqin
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 1007 - 1010
  • [5] Research on PD Detection Method under Induced Impulse Voltage for Stator Winding of Wind Turbine Generator
    Zhang, Tianlong
    Liu, Xuezhong
    Liu, Guanfang
    Lei, Pingzhen
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 520 - 523
  • [6] Study on Multi-factor Aging Characteristics of Stator Insulation for Wind Turbine Generator
    Ding Xiaoxia
    Liu Xuezhong
    Zhang Jianjun
    Zhang Tianlong
    Bai Yonggang
    Ren Wene
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [7] Electrical tree characteristics under AC and repetitive pulse voltages in wind turbine generator composite insulation
    Liu, Xuezhong
    Wang, Jingna
    Zhang, Rui
    Xue, Changzhi
    Chen, Hongsheng
    Li, Yanqin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (03) : 1007 - 1014
  • [8] PD Detection in Inter-turn Insulation of Wind Turbine Generator Under Induced Impulse Voltage
    Zhang Tianlong
    Liu Xuezhong
    Zhang Rui
    Liang Rui
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 316 - 319
  • [9] Experimental Research on Stator Insulation System of 5 MW Offshore Wind Turbine Generator under Simulated Marine Environments
    Liu Xuezhong
    Zhang Tianlong
    Bai Yonggang
    Ding Xiaoxia
    Wang Fangwen
    Chen Tangze
    Zhao Dan
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 52 - 55
  • [10] Condition Assessment Program on Aged High Voltage Insulation of In-Service Turbine Generator
    Kumar, P. G. S.
    Kumar, K. Kalyan
    2015 INTERNATIONAL CONFERENCE ON CONTROL COMMUNICATION & COMPUTING INDIA (ICCC), 2015, : 265 - 270