Effect of Respiratory Physiological Changes on Optic Nerve Sheath Diameter and Cerebral Oxygen Saturation in Patients With Acute Traumatic Brain Injury

被引:9
作者
Balakrishnan, Sweatha [1 ]
Naik, Shwetha [1 ]
Chakrabarti, Dhritiman [1 ]
Konar, Subhas [1 ]
Sriganesh, Kamath [1 ]
机构
[1] Natl Inst Mental Hlth & Neurosci, Bengaluru, Karnataka, India
关键词
traumatic brain injury; optic nerve sheath diameter; positive end-expiratory pressure; end-tidal carbon dioxide; regional cerebral oxygen saturation; END-EXPIRATORY PRESSURE; NEAR-INFRARED SPECTROSCOPY; INTRACRANIAL-PRESSURE; PEEP;
D O I
10.1097/ANA.0000000000000706
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Severe traumatic brain injury (TBI) results in raised intracranial pressure (ICP). Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) is a noninvasive method for the assessment of raised ICP. Manipulation of positive end-expiratory pressure (PEEP) and end-tidal carbon dioxide (ETCO2) are often used to optimize ICP and improve oxygenation in TBI patients. This study evaluated the effects of PEEP and ETCO2 on ONSD and regional cerebral oxygen saturation (rScO(2)) in patients with acute TBI. Methods: A total of 14 patients (11 males) aged older than 18 years with acute severe TBI were included in this study. ONSD and rScO(2) were assessed before and after changes in PEEP from 5 to 10 cmH(2)O and in ETCO2 from 40 to 30mmHg on both pathologic and nonpathologic sides. Results: Increasing PEEP and reducing ETCO2 resulted in changes in ONSD and rScO(2) on both pathologic and nonpathologic sides. On the pathologic side, ONSD and rScO(2) were highest with a PEEP of 10 cmH(2)O:ETCO2 40mmHg combination and lowest with PEEP of 5 cmH(2)O:ETCO2 30mmHg (ONSD 5.24 +/- 0.49 vs. 4.27 +/- 0.36 mm, P < 0.001; rScO(2) 70.7 +/- 9.91% vs. 66.3 +/- 9.75%, P < 0.001); both PEEP and ETCO2 had significant effects on ONSD and rScO(2) (P < 0.001). On the nonpathologic side, ONSD and rScO(2) were highest and lowest with PEEP of 10 cmH(2)O: ETCO2 40mmHg and PEEP of 5 cmH(2)O:ETCO2 30mmHg combinations, respectively (ONSD: 4.93 +/- 0.46 vs. 4.02 +/- 0.40mm, P < 0.001; rScO(2): 74.77 +/- 8.30% vs. 70.69 +/- 8.12%, P < 0.001). ETCO2 had a significant effect on rScO(2) (P < 0.001), but the impact of PEEP on rScO(2) was not statistically significant (P = 0.05). Conclusion: Increasing PEEP resulted in significant increases in ONSD and rScO(2), whereas reducing ETCO2 significantly decreased ONSD and rScO(2).
引用
收藏
页码:E52 / E56
页数:5
相关论文
共 50 条
  • [31] Intracranial Pressure Assessment in Traumatic Head Injury with Hemorrhage Via Optic Nerve Sheath Diameter
    Vaiman, Michael
    Sigal, Tal
    Kimiagar, Itzhak
    Bekerman, Inessa
    JOURNAL OF NEUROTRAUMA, 2016, 33 (23) : 2147 - 2153
  • [32] Ultrasonic measurement of optic nerve sheath diameter in elderly patients with craniocerebral injury
    Qiao, Zhifei
    Wang, Lei
    Li, Shutie
    Li, Yuanli
    Gao, Naikun
    Jia, Liqun
    Liu, Chunyan
    Zhai, Liping
    Li, Fulong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (04): : 3466 - 3472
  • [33] Optic Nerve Sheath Measurements by Computed Tomography to Predict Intracranial Pressure and Guide Surgery in Patients with Traumatic Brain Injury
    Liu, Meng
    Yang, Zhi-Kun
    Yan, Yu-Feng
    Shen, Xiao
    Yao, Hui-Bin
    Fei, Li
    Wang, Er-Song
    WORLD NEUROSURGERY, 2020, 134 : E317 - E324
  • [34] Computed Tomography Optic Nerve Sheath Diameter-to-Eyeball Transverse Diameter Ratio as a Novel Noninvasive Parameter for Prognostication in Traumatic Brain Injury
    Sharma, Praveen K.
    Natarajan, Paarthipan
    Ramakrishnan, Karthik Krishna
    Aram, Arun
    Subramonian, Sakthi Ganesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [35] Optic nerve sheath diameter and pulsatility index for the diagnosis and follow-up in pediatric traumatic brain injury: a prospective observational cohort study
    Ozlem Saritas Nakip
    Mehmet Yasir Pektezel
    Kivanc Terzi
    Selman Kesici
    Benan Bayrakci
    Child's Nervous System, 2023, 39 : 2467 - 2477
  • [36] Effect of a cervical collar on optic nerve sheath diameter in trauma patients
    Yazici, Mumin Murat
    Yavasi, Ozcan
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2024, 15 (02) : 126 - 130
  • [37] Optic nerve sheath diameter and pulsatility index for the diagnosis and follow-up in pediatric traumatic brain injury: a prospective observational cohort study
    Saritas Nakip, Ozlem
    Pektezel, Mehmet Yasir
    Terzi, Kivanc
    Kesici, Selman
    Bayrakci, Benan
    CHILDS NERVOUS SYSTEM, 2023, 39 (09) : 2467 - 2477
  • [38] Value of Ultrasonographic Optic Nerve Sheath Diameter in Assessing Increased Intracranial Pressure in Patients With Moderate to Severe Traumatic Brain Injury
    A Abdalla
    BN Beshey
    AM Abougabal
    KM Elzahaby
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [39] Optic Nerve Sheath Diameter Sonography for the Diagnosis of Intracranial Hypertension in Traumatic Brain Injury: A Systematic Review and Meta-Analysis
    Xu, Jie
    Song, Yinghua
    Nayaz, Burkutally Muhammad Shah
    Shi, Weitao
    Zhao, Yun
    Liu, Yawen
    Wu, Suming
    Li, Zhi
    Sun, Yanhu
    Zhao, Yuliang
    Yu, Wenkui
    Wang, Xudong
    WORLD NEUROSURGERY, 2024, 182 : 136 - 143
  • [40] Comparison of the Effects of Normocapnia and Mild Hypercapnia on the Optic Nerve Sheath Diameter and Regional Cerebral Oxygen Saturation in Patients Undergoing Gynecological Laparoscopy with Total Intravenous Anesthesia
    Park, Chun-Gon
    Jung, Wol-Seon
    Park, Hee-Yeon
    Kim, Hye-Won
    Kwak, Hyun-Jeong
    Jo, Youn-Yi
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (20)