A prototype quantitative film scanner for radiochromic film dosimetry

被引:14
作者
Ranade, Manisha K.
Li, Jonathan G.
Dubose, Ryan S. [1 ]
Kozelka, Jakub [2 ]
Simon, William E. [2 ]
Dempsey, James F.
机构
[1] Spartanburg Reg Hosp Gibbs Canc Ctr, Spartanburg, SC 29303 USA
[2] Sun Nucl Corp, Melbourne, FL 32940 USA
关键词
densitometer; film dosimetry; radiochromic film;
D O I
10.1118/1.2828203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction externalbeam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RC,F dosimetry. The scanner employed a stationary light source and detector with a moving antireflective glass film platen attached to a high precision computerized X-Y translation stage. An ultrabright red light emitting diode (LED) with a peak output at 633 nm and full width at half maximum (FWHM) of 16 nm was selected as the scanner light source to match the RCF absorption peak. A dual detector system was created using two silicon photodiode detectors to simultaneously measure incident and transmitted light. The LED light output was focused to a submillimeter (FWHM 0.67 mm) spot size, which was determined from a scanning knife-edge technique for measuring Gaussian optical beams. Data acquisition was performed with a 16-bit A/D card in conjunction with commercial software. The linearity of the measured densities on the scanner was tested using a calibrated neutral-density step filter. Sensitometric curves and three IMRT field scans were acquired with a spatial resolution of I mm for both radiographic film and RCR The results were compared with measurements taken with a commercial diode array under identical delivery conditions. The RCF was rotated by. 90 deg and. rescanned to study orientation effects. Comparison between the RCF and the diode array measurements using percent dose difference and distance-to-agreement criteria produced average passing rates of 99.0% using 3%/3 rum criteria and 96.7% using 2%/2 rum criteria. The same comparison between the radiographic film and diode array measurements resulted in average passing rates 96.6% and 91.6% for the above two criteria, respectively. No measurable light-scatter or interference scanner artifacts were observed. The RCF rotated by 90 deg showed no measurable orientation effect. A scan of a 15 X 15 cm(2) area with I turn resolution required 22 min to acquire. The LED densitometer provides an accurate film dosimetry system with 4 rum or better resolution. The scanner eliminates the orientation dependence of RCF dosimetry that was previously reported with commercial flatbed scanners. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:473 / 479
页数:7
相关论文
共 50 条
  • [41] Linearization of dose-response curve of the radiochromic film dosimetry system
    Devic, Slobodan
    Tomic, Nada
    Aldelaijan, Saad
    DeBlois, Francois
    Seuntjens, Jan
    Chan, Maria F.
    Lewis, Dave
    MEDICAL PHYSICS, 2012, 39 (08) : 4850 - 4857
  • [42] Evaluation and implementation of triple-channel radiochromic film dosimetry in brachytherapy
    Palmer, Antony L.
    Bradley, David
    Nisbet, Andrew
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 280 - 296
  • [43] Radiochromic film dosimetry for UV-C treatments of apple fruit
    Yan, Ruixiang
    Yun, Juan
    Gurtler, Joshua
    Fan, Xuetong
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2017, 127 : 14 - 20
  • [44] Radiochromic film dosimetry in radiotherapy: a survey of current practice in the United Kingdom
    Palmer, Antony L.
    Nash, David
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1155) : 646 - 651
  • [45] Commissioning and evaluation of a radiochromic EBT3 film dosimetry system
    Khan, Muhammad Isa
    Tahir, Muhammad Bilal
    Rafique, Muhammad
    Iqbal, Tahir
    Zulfiqar, Sabiha
    Zahoor, Aliza
    Rehman, Jalil Ur
    Iqba, Khalid
    Chow, James
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 55 - 62
  • [46] Comparison of three high-resolution digitizers for radiochromic film dosimetry
    Gluckman, GR
    Reinstein, LE
    MEDICAL PHYSICS, 2002, 29 (08) : 1839 - 1846
  • [47] High sensitivity radiochromic film dosimetry using an optical common-mode rejection and a reflective-mode flatbed color scanner
    Ohuchi, Hiroko
    MEDICAL PHYSICS, 2007, 34 (11) : 4207 - 4212
  • [48] Radiochromic film dosimetry of a high dose rate beta source for intravascular brachytherapy
    Duggan, DM
    Coffey, CW
    Lobdell, JL
    Schell, MC
    MEDICAL PHYSICS, 1999, 26 (11) : 2461 - 2464
  • [49] Monte-Carlo based prediction of radiochromic film response for hadrontherapy dosimetry
    Frisson, T.
    Zahra, N.
    Lautesse, P.
    Sarrut, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 606 (03) : 749 - 754
  • [50] Novel applications of radiochromic film in radiation dosimetry at high-energy accelerators
    Mukherjee, B.
    Makowski, D.
    Krasinski, P.
    Cross, P.
    Grecki, M.
    Simrock, S.
    MIXDES 2008: PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2008, : 131 - +