Non-contrast-enhanced MR venography of the upper limb: a comparative study of acquisitions with fresh blood imaging vs. time-of-flight methods

被引:14
作者
Harigai, Motoko [1 ]
Okada, Tomohisa [1 ]
Umeoka, Shigeaki [1 ]
Nagayama, Satoshi [1 ]
Tanaka, Eiji [1 ]
Fujimoto, Koji [1 ]
Kido, Aki [1 ]
Takeda, Kazuna [1 ]
Togashi, Kaori [1 ]
Sakai, Yoshiharu [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Sakyo Ku, Kyoto 6068507, Japan
关键词
MR Venography; Non-contrast-enhanced; Fresh blood imaging; Time of flight; DEEP-VEIN THROMBOSIS; FAST SPIN-ECHO; VENOUS THROMBOSIS; ANGIOGRAPHY; HEMODIALYSIS; TRANSPOSITION; OUTCOMES; FISTULA; CANCER;
D O I
10.1016/j.clinimag.2012.01.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Non-contrast-enhanced magnetic resonance venography (MRV) of the upper limb acquired by fresh blood imaging (FBI) was compared with time-of-flight (TOF)-MRV. Visualization of three veins (basilic, brachial, and cephalic veins), small branches, and fat suppression was evaluated with a four-point scale (0-3). FBI-MRV was significantly superior for the basilic veins and small venous branches and equivalent for the brachial and cephalic veins to TOF-MRV, with no difference in fat suppression. FBI-MRV would be useful in venous mapping and detection of thrombus. (c) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:496 / 501
页数:6
相关论文
共 25 条
[1]  
[Anonymous], 1997, Am J Kidney Dis, V30, pS150
[2]   Old and new risk factors for upper extremity deep venous thrombosis [J].
Blom, JW ;
Doggen, CJM ;
Osanto, S ;
Rosendaal, FR .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2005, 3 (11) :2471-2478
[3]   MR venography with true fast imaging with steady-state precession for suspected lower-limb deep vein thrombosis [J].
Cantwell, Colin Patrick ;
Cradock, Andrea ;
Bruzzi, John ;
Fitzpatrick, Patricia ;
Eustace, Stephen ;
Murray, John G. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (11) :1763-1769
[4]   MAGNETIC-RESONANCE VENOGRAPHY FOR THE DETECTION OF DEEP VENOUS THROMBOSIS - COMPARISON WITH CONTRAST VENOGRAPHY AND DUPLEX-DOPPLER ULTRASONOGRAPHY [J].
CARPENTER, JP ;
HOLLAND, GA ;
BAUM, RA ;
OWEN, RS ;
CARPENTER, JT ;
COPE, C .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (05) :734-741
[5]  
DAGHER FJ, 1986, J CARDIOVASC SURG, V27, P447
[6]   Unenhanced Flow-Independent MR Venography by Using Signal Targeting Alternative Radiofrequency and Flow-Independent Relaxation Enhancement [J].
Edelman, Robert R. ;
Koktzoglou, Ioannis .
RADIOLOGY, 2009, 250 (01) :236-245
[7]   DETECTION OF DEEP VENOUS THROMBOSIS - PROSPECTIVE COMPARISON OF MR-IMAGING WITH CONTRAST VENOGRAPHY [J].
EVANS, AJ ;
SOSTMAN, HD ;
KNELSON, MH ;
SPRITZER, CE ;
NEWMAN, GE ;
PAINE, SS ;
BEAM, CA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) :131-139
[8]  
Glockner JF, 2010, Appl Radiol, V39, P36, DOI [10.37549/AR1758, DOI 10.37549/AR1758]
[9]   Upper-extremity deep vein thrombosis - A prospective registry of 592 patients [J].
Joffe, HV ;
Kucher, N ;
Tapson, VF ;
Goldhaber, SZ .
CIRCULATION, 2004, 110 (12) :1605-1611
[10]   Relationship of preoperative venous and arterial imaging findings to outcomes of brachio-basilic transposition fistulae for hemodialysis: A prospective clinical study [J].
Karakayali, F. Y. ;
Sevmis, S. ;
Basaran, C. ;
Yabanoglu, H. ;
Arat, Z. ;
Boyvat, F. ;
Haberal, M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 35 (02) :208-213