Application of a time-resolved optical brain imager for monitoring cerebral oxygenation during carotid surgery

被引:33
|
作者
Kacprzak, Michal [1 ]
Liebert, Adam [1 ]
Staszkiewicz, Walerian [2 ]
Gabrusiewicz, Andrzej [2 ]
Sawosz, Piotr [1 ]
Madycki, Grzegorz [2 ]
Maniewski, Roman [1 ]
机构
[1] Nalecz Inst Biocybernet & Biomed Engn PAS, PL-02109 Warsaw, Poland
[2] Med Ctr Postgrad Educ, Dept Vasc Surg & Angiol, PL-01813 Warsaw, Poland
关键词
time-resolved imaging; light propagation in tissues; medical optics instrumentation; NEAR-INFRARED SPECTROSCOPY; SOMATOSENSORY-EVOKED POTENTIALS; DOPPLER ULTRASONOGRAPHY; STUMP PRESSURE; ENDARTERECTOMY; ISCHEMIA; SATURATION; PERFUSION; STENOSIS; OXIMETRY;
D O I
10.1117/1.JBO.17.1.016002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent studies have shown that time-resolved optical measurements of the head can estimate changes in the absorption coefficient with depth discrimination. Thus, changes in tissue oxygenation, which are specific to intracranial tissues, can be assessed using this advanced technique, and this method allows us to avoid the influence of changes to extracerebral tissue oxygenation on the measured signals. We report the results of time-resolved optical imaging that was carried out during carotid endarterectomy. This surgery remains the "gold standard" treatment for carotid stenosis, and intraoperative brain oxygenation monitoring may improve the safety of this procedure. A time-resolved optical imager was utilized within the operating theater. This instrument allows for the simultaneous acquisition of 32 distributions of the time-of-flight of photons at two wavelengths on both hemispheres. Analysis of the statistical moments of the measured distributions of the time-of-flight of photons was applied for estimating changes in the absorption coefficient as a function of depth. Time courses of changes in oxy- and deoxyhemoglobin of the extra- and intracerebral compartments during cross-clamping of the carotid arteries were obtained. A decrease in the oxyhemoglobin concentration and an increase in the deoxyhemoglobin concentrations were observed in a large area of the head. Large changes were observed in the hemisphere ipsilateral to the site of clamped carotid arteries. Smaller amplitude changes were noted at the contralateral site. We also found that changes in the hemoglobin signals, as estimated from intracerebral tissue, are very sensitive to clamping of the internal carotid artery, whereas its sensitivity to clamping of the external carotid artery is limited. We concluded that intraoperative multichannel measurements allow for imaging of brain tissue hemodynamics. However, when monitoring the brain during carotid surgery, a single-channel measurement may be sufficient. (c) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.1.016002]
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Can time-resolved NIRS provide the sensitivity to detect brain activity during motor imagery consistently?
    Abdalmalak, Androu
    Milej, Daniel
    Diop, Mamadou
    Shokouhi, Mahsa
    Naci, Lorina
    Owen, Adrian M.
    St Lawrence, Keith
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (04): : 2162 - 2172
  • [32] HyperTRCSS: A hyperspectral time-resolved compressive sensing spectrometer for depth-sensitive monitoring of cytochrome-c-oxidase and blood oxygenation
    Li, Natalie C.
    Ioussoufovitch, Seva
    Diop, Mamadou
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (01)
  • [33] Optical monitoring of cerebral perfusion and metabolism in adults during cardiac surgery with cardiopulmonary bypass
    Rajaram, Ajay
    Milej, Daniel
    Suwalski, Marianne
    Yip, Lawrence C. M.
    Guo, Linrui R.
    Chu, Michael W. A.
    Chui, Jason
    Diop, Mamadou
    Murkin, John M.
    St Lawrence, Keith
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (10) : 5967 - 5981
  • [34] Spread spectrum time-resolved diffuse optical measurement system for enhanced sensitivity in detecting human brain activity
    Mehta, Kalpesh
    Hasnain, Ali
    Zhou, Xiaowei
    Luo, Jianwen
    Penney, Trevor B.
    Chen, Nanguang
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (04)
  • [35] MONSTIR II: A 32-channel, multispectral, time-resolved optical tomography system for neonatal brain imaging
    Cooper, Robert J.
    Magee, Elliott
    Everdell, Nick
    Magazov, Salavat
    Varela, Marta
    Airantzis, Dimitrios
    Gibson, Adam P.
    Hebden, Jeremy C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (05):
  • [36] The effectiveness of cerebral oxygenation monitoring during arthroscopic shoulder surgery in the beach chair position: a randomized blinded study
    Cox, Ryan M.
    Jamgochian, Grant C.
    Nicholson, Kristen
    Wong, Justin C.
    Namdari, Surena
    Abboud, Joseph A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (04) : 692 - 700
  • [37] Cerebral monitoring during carotid endarterectomy using near-infrared diffuse optical spectroscopies and electroencephalogram
    Shang, Yu
    Cheng, Ran
    Dong, Lixin
    Ryan, Stephen J.
    Saha, Sibu P.
    Yu, Guoqiang
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (10): : 3015 - 3032
  • [38] Continuous monitoring of absolute cerebral blood flow by combining diffuse correlation spectroscopy and time-resolved near-infrared technology
    Diop, Mamadou
    Lee, Ting-Yim
    Lawrence, Keith St.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [39] Time-resolved quantification of the dynamic extracellular space in the brain during short-lived event: methodology and simulations
    Chen, Kevin C.
    Zhou, Yi
    Zhao, Hui-Hui
    JOURNAL OF NEUROPHYSIOLOGY, 2019, 121 (05) : 1718 - 1734
  • [40] An algorithm for assessment of inflow and washout of optical contrast agent to the brain by analysis of time-resolved diffuse reflectance and fluorescence signals
    Milej, D.
    Kruczkowski, M.
    Gerega, A.
    Sawosz, P.
    Maniewski, R.
    Liebert, A.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1919 - 1922