Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis

被引:11
|
作者
Kim, Mi Sung [1 ]
Kwon, Heon-Ju [1 ]
Kang, Kyung A. [1 ]
Do, In-Gu [2 ]
Park, Hee-Jin [1 ]
Kim, Eun Young [1 ]
Hong, Hyun Pyo [1 ]
Choi, Yoon Jung [1 ]
Kim, Young Hwan [3 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Radiol, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Pathol, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Nucl Med, Seoul, South Korea
关键词
LOWER QUADRANT PAIN; SUSPECTED APPENDICITIS; GRADED COMPRESSION; HELICAL CT; COMPUTED-TOMOGRAPHY; CONTRAST MATERIAL; SONOGRAPHY; US; CRITERIA; VISUALIZATION;
D O I
10.1259/bjr.20170529
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. Methods: 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. Results: There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Conclusion: Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis.
引用
收藏
页数:9
相关论文
共 47 条
  • [31] Diagnostic performance of a biomarker panel as a negative predictor for acute appendicitis in adult ED patients with abdominal pain
    Huckins, David S.
    Copeland, Karen
    Self, Wesley
    Vance, Cheryl
    Hendry, Phyllis
    Borg, Keith
    Gogain, Joseph
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (03) : 418 - 424
  • [32] In vivo identification of uric acid stones with dual-energy CT: diagnostic performance evaluation in patients
    Stolzmann, Paul
    Kozomara, Marko
    Chuck, Natalie
    Muentener, Michael
    Leschka, Sebastian
    Scheffel, Hans
    Alkadhi, Hatem
    ABDOMINAL IMAGING, 2010, 35 (05): : 629 - 635
  • [33] Reduced scan range abdominopelvic CT in patients with suspected acute appendicitis - impact on diagnostic accuracy and effective radiation dose
    Dominik Zinsser
    Michael Maurer
    Phuong-Linh Do
    Jakob Weiß
    Mike Notohamiprodjo
    Fabian Bamberg
    Ahmed E. Othman
    BMC Medical Imaging, 19
  • [34] Reduced scan range abdominopelvic CT in patients with suspected acute appendicitis - impact on diagnostic accuracy and effective radiation dose
    Zinsser, Dominik
    Maurer, Michael
    Phuong-Linh Do
    Weiss, Jakob
    Notohamiprodjo, Mike
    Bamberg, Fabian
    Othman, Ahmed E.
    BMC MEDICAL IMAGING, 2019, 19 (1)
  • [35] Low tube voltage increases the diagnostic performance of dual-energy computed tomography in patients with acute appendicitis
    Topel, Cagdas
    Onur, Mehmet Ruhi
    Akpinar, Erhan
    Karaosmanoglu, Ali Devrim
    Akata, Deniz
    Karcaaltincaba, Musturay
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (04) : 257 - 264
  • [36] Global and Regional Diagnostic Accuracy of Lung Ultrasound Compared to CT in Patients With Acute Respiratory Distress Syndrome*
    Chiumello, Davide
    Umbrello, Michele
    Papa, Giuseppe Francesco Sferrazza
    Angileri, Alessio
    Gurgitano, Martina
    Formenti, Paolo
    Coppola, Silvia
    Froio, Sara
    Cammaroto, Antonio
    Carrafiello, Gianpaolo
    CRITICAL CARE MEDICINE, 2019, 47 (11) : 1599 - 1606
  • [37] Current usage and diagnostic performance of cross-sectional imaging in patients with suspected acute appendicitis: a national survey in China
    Ma, Li
    Niu, Zihan
    Xu, Wen
    Wang, Ruojiao
    Gao, Luying
    Tao, Xixi
    Jiang, Yuxin
    Li, Jianchu
    Wang, Hongyan
    ABDOMINAL RADIOLOGY, 2024, : 1979 - 1985
  • [38] Comparative Performance of Pulmonary Ultrasound, Chest Radiograph, and CT Among Patients With Acute Respiratory Failure*
    Tierney, David M.
    Huelster, Joshua S.
    Overgaard, Josh D.
    Plunkett, Michael B.
    Boland, Lori L.
    St Hill, Catherine A.
    Agboto, Vincent K.
    Smith, Claire S.
    Mikel, Bryce F.
    Weise, Brynn E.
    Madigan, Katelyn E.
    Doshi, Ameet P.
    Melamed, Roman R.
    CRITICAL CARE MEDICINE, 2020, 48 (02) : 151 - 157
  • [39] Diagnostic performance and image quality of an image-based denoising algorithm applied to radiation dose-reduced CT in diagnosing acute appendicitis
    Choi, Hyeon Ui
    Cho, Jungheum
    Hwang, Jinhee
    Lee, Seungjae
    Chang, Won
    Park, Ji Hoon
    Lee, Kyoung Ho
    ABDOMINAL RADIOLOGY, 2024, 49 (06) : 1839 - 1849
  • [40] Diagnostic Performance of MRI Versus CT in the Evaluation of Intra-articular Osteochondral Fracture in Pediatric Patients With Acute Traumatic Lateral Patellar Dislocation
    Wu, Zhen-Kai
    Dai, Zhen-Zhen
    Sha, Lin
    Li, Hao
    Li, Tai-Chun
    Zhang, Zi-Ming
    Li, Hai
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (03)