Application of a dispersive micro-solid-phase extraction method for pre-concentration and ultra-trace determination of cadmium ions in water and biological samples

被引:40
|
作者
Behbahani, Mohammad [1 ]
Veisi, Ali [2 ]
Omidi, Fariborz [3 ]
Noghrehabadi, Aminreza [4 ]
Esrafili, Ali [5 ]
Ebrahimi, Mohammad Hossein [6 ]
机构
[1] Shohadaye Hoveizeh Univ Technol, Fac Engn, Dasht E Azadegan, Susangerd, Iran
[2] Behbahan Fac Med Sci, Behbahan, Iran
[3] Kermanshah Univ Med Sci, RCEDH, Kermanshah, Iran
[4] Shahid Chamran Univ Ahvaz, Dept Mech Engn, Ahvaz, Iran
[5] Iran Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[6] Shahroud Univ Med Sci, Occupat & Environm Hlth Res Ctr, Shahroud, Iran
关键词
Box-Behnken design; cadmium ions; modified magnetic nanoparticles; UA-D-SPE; water and biological samples; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; CLOUD POINT EXTRACTION; MAGNETIC NANOPARTICLES; ACTIVATED CARBON; BLOOD CADMIUM; SENSOR; LEAD; SYSTEM; FOOD;
D O I
10.1002/aoc.4134
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method for the trace determination of cadmium ions in water, human urine and human blood serum samples using ultrasonic-assisted dispersive micro-solid-phase extraction (UA-D-SPE) was developed. Silica-coated magnetic nanoparticles were coated with polythiophene, and the resulting sorbent was characterized using thermogravimetry, differential thermal analysis, scanning electron microscopy, Fourier transform infrared spectrometry and X-ray diffraction. Following UA-D-SPE, cadmium ions were quantified using graphite furnace atomic absorption spectrometry. A Box-Behnken design was used for optimization of important sorption and desorption parameters in UA-D-SPE: in the sorption step, pH of solution, sorption amount and sonication time for sorption; in the desorption step, concentration of eluent, volume of eluent and sonication time. The optimum conditions for the method were: pH of solution, 7.5; sonication time for sorption, 3min; sorption amount, 35mg; type and concentration of eluent, HCl and 1.1mol l(-1); volume of eluent, 360 l; sonication time for desorption, 110s. Under the optimized conditions the limit of detection and relative standard deviation for the detection of cadmium ions by UA-D-SPE were found to be 0.8ng l(-1) and <6%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] In situ solvent formation microextraction combined with magnetic dispersive micro-solid-phase extraction for the determination of benzoylurea insecticides in water samples
    Zhang, Ying
    Yang, Xiaoling
    Wang, Jiankang
    Zhou, Wenfeng
    Lu, Runhua
    Gao, Haixiang
    Zhang, Sanbing
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (02) : 442 - 448
  • [22] Magnetic nanoparticles based dispersive micro-solid-phase extraction as a novel technique for the determination of estrogens in pork samples
    Wang, Juan
    Chen, Zhiyan
    Li, Zhiming
    Yang, Yaling
    FOOD CHEMISTRY, 2016, 204 : 135 - 140
  • [23] Ionic Liquid Based Dispersive Liquid-Liquid Microextraction Combined with Magnetic-Based Dispersive Micro-Solid-Phase Extraction for Determination of Trace Cobalt in Water Samples by FAAS
    Filik, Hayati
    Avan, Asiye Aslihan
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (06) : 456 - 463
  • [24] Application of deep eutectic solvent based magnetic colloidal gel for dispersive solid phase extraction of ultra-trace amounts of some nitroaromatic compounds in water samples
    Zarei, Ali Reza
    Nedaei, Maryam
    Ghorbanian, Sohrab Ali
    JOURNAL OF MOLECULAR LIQUIDS, 2017, 246 : 58 - 65
  • [25] Column solid phase extraction and determination of ultra-trace Au, Pd and Pt in environmental and geological samples
    Mladenova, Elisaveta
    Dakova, Ivanka
    Karadjova, Irina
    Karadjov, Methody
    MICROCHEMICAL JOURNAL, 2012, 101 : 59 - 64
  • [26] Customized dispersive micro-solid-phase extraction device combined with micro-desorption for the simultaneous determination of 39 multiclass pesticides in environmental water samples
    Nascimento, Madson Moreira
    da Rocha, Gisele Olimpio
    de Andrade, Jailson B.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1639
  • [27] On-line Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction Based on Amino Bimodal Mesoporous Silica Nanoparticles for the Preconcentration and Determination of Cadmium in Human Biological Samples
    H. Shirkhanloo
    M. Falahnejad
    H. Zavvar Mousavi
    Biological Trace Element Research, 2016, 171 : 472 - 481
  • [28] On-line Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction Based on Amino Bimodal Mesoporous Silica Nanoparticles for the Preconcentration and Determination of Cadmium in Human Biological Samples
    Shirkhanloo, H.
    Falahnejad, M.
    Mousavi, H. Zavvar
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2016, 171 (02) : 472 - 481
  • [29] Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples
    Yang, Xiupei
    Jia, Zhihui
    Yang, Xiaocui
    Li, Gu
    Liao, Xiangjun
    SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2017, 24 (03) : 589 - 594
  • [30] Ionic imprinted polymer based solid phase extraction for cadmium and lead pre-concentration/determination in seafood
    Barciela-Alonso, M. C.
    Plata-Garcia, V.
    Rouco-Lopez, A.
    Moreda-Pineiro, A.
    Bermejo-Barrera, P.
    MICROCHEMICAL JOURNAL, 2014, 114 : 106 - 110