Pulse Arrival Time is Not an Adequate Surrogate for Pulse Transit Time in Terms of Tracking Diastolic Pressure

被引:0
|
作者
Zhang, Guanqun [1 ]
Xu, Da [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
来源
2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2011年
关键词
PRE-EJECTION PERIOD; BLOOD-PRESSURE; WAVE VELOCITY; MARKER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared pulse arrival time (PAT) and pulse transit time (PTT) in terms of their ability to track diastolic pressure (DP). We performed the comparison using high fidelity, invasive arterial waveforms recorded from six dogs during multiple interventions. On average, DP ranged from 40 to 106 mmHg and therefore varied widely. PAT and PTT were able to predict DP with average root-mean-squared-errors of 9.8 +/- 5.8 mmHg and 5.7 +/- 2.0 mmHg (p = 0.02). Thus, even though PAT is simpler to measure, we can only recommend using PTT for tracking DP.
引用
收藏
页码:6462 / 6464
页数:3
相关论文
共 50 条
  • [41] Non-invasive pulse arrival time as a surrogate for oscillometric systolic blood pressure changes during non-pharmacological intervention
    Hametner, Bernhard
    Maurer, Severin
    Sehnert, Alina
    Bachler, Martin
    Orter, Stefan
    Zechner, Olivia
    Mullner-Rieder, Markus
    Penkler, Michael
    Wassertheurer, Siegfried
    Sehnert, Walter
    Mengden, Thomas
    Mayer, Christopher C.
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (05)
  • [42] A Linear Transformation Approach for Estimating Pulse Arrival Time
    Kim, Dohyun
    Ahn, Jong-Hoon
    Lee, Jongshill
    Park, Hoon Ki
    Kim, In Young
    JOURNAL OF APPLIED MATHEMATICS, 2012,
  • [43] Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement
    Patzak, Andreas
    Mendoza, Yuri
    Gesche, Heiko
    Konermann, Martin
    BLOOD PRESSURE, 2015, 24 (04) : 217 - 221
  • [44] Measurement of Pulse Transit Time (PTT) Using Photoplethysmography
    Lokharan, M.
    Kumar, Lokesh K. C.
    Kumar, Harish, V
    Kayalvizhi, N.
    Aryalekshmi, R.
    16TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2017, 61 : 130 - 134
  • [45] Pulse wave transit time for monitoring respiration rate
    Johansson, A.
    Ahlstrom, C.
    Lanne, T.
    Ask, P.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (06) : 471 - 478
  • [46] Pulse wave transit time for monitoring respiration rate
    A. Johansson
    C. Ahlstrom
    T. Lanne
    P. Ask
    Medical and Biological Engineering and Computing, 2006, 44 : 471 - 478
  • [47] Radial pulse transit time is an index of arterial stiffness
    Yong-Liang Zhang
    Ying-Ying Zheng
    Zu-Chang Ma
    Yi-Ning Sun
    Hypertension Research, 2011, 34 : 884 - 887
  • [48] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [49] Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice
    Mukkamala, Ramakrishna
    Hahn, Jin-Oh
    Inan, Omer T.
    Mestha, Lalit K.
    Kim, Chang-Sei
    Toreyin, Hakan
    Kyal, Survi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 1879 - 1901
  • [50] Radial pulse transit time is an index of arterial stiffness
    Zhang, Yong-Liang
    Zheng, Ying-Ying
    Ma, Zu-Chang
    Sun, Yi-Ning
    HYPERTENSION RESEARCH, 2011, 34 (07) : 884 - 887