Pulse Arrival Time is Not an Adequate Surrogate for Pulse Transit Time in Terms of Tracking Diastolic Pressure

被引:0
|
作者
Zhang, Guanqun [1 ]
Xu, Da [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
来源
2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2011年
关键词
PRE-EJECTION PERIOD; BLOOD-PRESSURE; WAVE VELOCITY; MARKER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared pulse arrival time (PAT) and pulse transit time (PTT) in terms of their ability to track diastolic pressure (DP). We performed the comparison using high fidelity, invasive arterial waveforms recorded from six dogs during multiple interventions. On average, DP ranged from 40 to 106 mmHg and therefore varied widely. PAT and PTT were able to predict DP with average root-mean-squared-errors of 9.8 +/- 5.8 mmHg and 5.7 +/- 2.0 mmHg (p = 0.02). Thus, even though PAT is simpler to measure, we can only recommend using PTT for tracking DP.
引用
收藏
页码:6462 / 6464
页数:3
相关论文
共 50 条
  • [31] Pulse Transit Time-Pulse Wave Analysis Fusion Based on Wearable Wrist Ballistocardiogram for Cuff-Less Blood Pressure Trend Tracking
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin Sadat
    Tivay, Ali
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung Hoon
    Lee, Jongwook
    Kwon, Ui-Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE ACCESS, 2020, 8 : 138077 - 138087
  • [32] Correlation of Pulse Wave Transit Time with Pulmonary Artery Pressure in a Porcine Model of Pulmonary Hypertension
    Mueller-Graf, Fabian
    Merz, Jonas
    Bandorf, Tim
    Albus, Chiara Felicitas
    Henkel, Maike
    Krukewitt, Lisa
    Kuehn, Volker
    Reuter, Susanne
    Vollmar, Brigitte
    Pulletz, Sven
    Boehm, Stephan H.
    Reuter, Daniel A.
    Zitzmann, Amelie
    BIOMEDICINES, 2021, 9 (09)
  • [33] Continuous and Noninvasive Blood Pressure Estimation by Two-Sensor Measurement of Pulse Transit Time
    Rasool, Anam
    Rafiq, Muqudas
    Nasir, Aisha
    Kashif, Faisal M.
    2018 14TH INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2018,
  • [34] Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity
    Sola, Josep
    Vetter, Rolf
    Renevey, Philippe
    Chetelat, Olivier
    Sartori, Claudio
    Rimoldi, Stefano F.
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (07) : 603 - 615
  • [35] PULSE TRANSIT-TIME - RELATIONSHIP TO BLOOD-PRESSURE AND MYOCARDIAL PERFORMANCE
    OBRIST, PA
    LIGHT, KC
    MCCUBBIN, JA
    HUTCHESON, JS
    HOFFER, JL
    PSYCHOPHYSIOLOGY, 1979, 16 (03) : 292 - 301
  • [36] Adaptive Algorithm for Continuous Monitoring of Blood Pressure Using a Pulse Transit Time
    Jadooei, Ali
    Zaderykhin, O.
    Shulgin, V. I.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 297 - 301
  • [37] Continuous monitoring of cerebrovascular reactivity through pulse transit time and intracranial pressure
    Liu, Xiuyun
    Gadhoumi, Kais
    Xiao, Ran
    Tran, Nate
    Smielewski, Peter
    Czosnyka, Marek
    Hetts, Steven W.
    Ko, Nerissa
    Hu, Xiao
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (01)
  • [38] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178
  • [39] Implantable Reflectance Pulse Transit Time Blood Pressure Sensor with Oximetry Capability
    Fiala, J.
    Gehrke, R.
    Theodor, M.
    Bingger, P.
    Frster, K.
    Heilmann, C.
    Beyersdorf, F.
    Zappe, H.
    Seifert, A.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE II, 2010, 7715
  • [40] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806