Pulse Arrival Time is Not an Adequate Surrogate for Pulse Transit Time in Terms of Tracking Diastolic Pressure

被引:0
|
作者
Zhang, Guanqun [1 ]
Xu, Da [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
来源
2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2011年
关键词
PRE-EJECTION PERIOD; BLOOD-PRESSURE; WAVE VELOCITY; MARKER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared pulse arrival time (PAT) and pulse transit time (PTT) in terms of their ability to track diastolic pressure (DP). We performed the comparison using high fidelity, invasive arterial waveforms recorded from six dogs during multiple interventions. On average, DP ranged from 40 to 106 mmHg and therefore varied widely. PAT and PTT were able to predict DP with average root-mean-squared-errors of 9.8 +/- 5.8 mmHg and 5.7 +/- 2.0 mmHg (p = 0.02). Thus, even though PAT is simpler to measure, we can only recommend using PTT for tracking DP.
引用
收藏
页码:6462 / 6464
页数:3
相关论文
共 50 条
  • [21] Prototype of Wearable Device for Blood Pressure using Pulse Transit Time
    Bunkum, Manao
    Wanluk, Nutthanan
    Visitsattapongse, Sarinporn
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [22] An implantable optical blood pressure sensor based on pulse transit time
    Jens Fiala
    Philipp Bingger
    Dominic Ruh
    Katharina Foerster
    Claudia Heilmann
    Friedhelm Beyersdorf
    Hans Zappe
    Andreas Seifert
    Biomedical Microdevices, 2013, 15 : 73 - 81
  • [23] A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time
    Buxi, Dilpreet
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (03) : R1 - R26
  • [24] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315
  • [25] Cuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time
    Yoon, Young-Zoon
    Kang, Jae Min
    Kwon, Yongjoo
    Park, Sangyun
    Noh, Seungwoo
    Kim, Younho
    Park, Jongae
    Hwang, Sung Woo
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (04) : 1068 - 1074
  • [26] The influence of heart rate on the relationship between pulse transit time and systolic blood pressure
    Fu, Zhizhong
    Song, Xinyue
    Qin, Tianyi
    Chen, Yifan
    Ding, Xiaorong
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (10)
  • [27] Toward a Smartphone Application for Estimation of Pulse Transit Time
    Liu, He
    Ivanov, Kamen
    Wang, Yadong
    Wang, Lei
    SENSORS, 2015, 15 (10) : 27303 - 27321
  • [28] Pulse Arrival Time Measurement with Coffee Provocation
    Ahmaniemi, Teemu
    Rajala, Satu
    Lindholm, Harri
    Taipalus, Tapio
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 254 - 257
  • [29] Effect of confounding factors on blood pressure estimation using pulse arrival time
    Kim, Jung Soo
    Kim, Ko Keun
    Baek, Hyun Jae
    Park, Kwang Suk
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (05) : 615 - 624
  • [30] Estimation of Cuffless Systolic and Diastolic Blood Pressure Using Pulse Transient Time
    Mehrabbeik, Mahtab
    Rashidi, Saeid
    2019 5TH IRANIAN CONFERENCE ON SIGNAL PROCESSING AND INTELLIGENT SYSTEMS (ICSPIS 2019), 2019,