Nusselt number and friction factor correlations for forced convective type counter flow solar air heater having discrete multi V shaped and staggered rib roughness on both sides of the absorber plate

被引:103
作者
Ravi, Ravi Kant [1 ]
Saini, R. P. [1 ]
机构
[1] Indian Inst Technol, Alternate Hydro Energy Ctr, Roorkee, Uttarakhand, India
关键词
Double pass solar air heater; Artificial roughness; Nusselt number; Friction factor; THERMOHYDRAULIC PERFORMANCE; ARTIFICIAL ROUGHNESS; THERMAL PERFORMANCE; DUCT; CHANNELS; SURFACES; ELEMENTS; ANGLE; GAP;
D O I
10.1016/j.applthermaleng.2017.10.080
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, the results of an experimental study on heat transfer and friction factor in a counter flow double pass solar air heater (DPSAH) duct with discrete multi V-shaped and staggered rib roughness on two broad surfaces of the heated plate have been investigated. The investigation covers a wide range of Reynolds number (Re) from 2000 to 20,000, relative staggered rib pitch (p'/p) from 0.2 to 0.8, relative staggered rib size (r/e) from 1 to 4 and relative roughness width (W/w) from 5 to 8. The optimum values of flow and geometrical parameters of roughness have been attained and explained in detail. For the Nusselt number (Nu), the maximum increase of 4.52 times to the corresponding value of smooth double pass duct has been achieved, however it has also been seen that the friction factor (f) enhanced by 3.13 folds as compared to smooth one. The rib parameters corresponding to maximum increase in Nu and f are r/e = 3.5, p'/p = 0.6 and W/w = 7. Further, correlations for Nu and f have also been developed on the basis of experimental data. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:735 / 746
页数:12
相关论文
共 38 条
[1]  
[Anonymous], 2013, INT J MECH ENG TECHN
[2]   A review of the performance of double pass solar air heater [J].
Chamoli, Sunil ;
Chauhan, Ranchan ;
Thakur, N. S. ;
Saini, J. S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01) :481-492
[3]  
EI-Sebaii A.A., 2011, APPL ENERG, V88, P1727
[4]   Analytical approach for evaluation of thermo hydraulic performance of roughened solar air heater [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
CASE STUDIES IN THERMAL ENGINEERING, 2016, 8 :19-31
[5]   Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L-shaped ribs [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
SOLAR ENERGY, 2016, 131 :275-295
[6]   Experimental and CFD-based thermal performance prediction of solar air heater provided with right-angle triangular rib as artificial roughness [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (02) :551-579
[7]   A review of CFD methodology used in literature for predicting thermo-hydraulic performance of a roughened solar air heater [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 54 :550-605
[8]   HEAT-TRANSFER AND FRICTION CHARACTERISTICS IN RECTANGULAR CHANNELS WITH RIB TURBULATORS [J].
HAN, JC .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1988, 110 (02) :321-328
[9]   AUGMENTED HEAT-TRANSFER IN SQUARE CHANNELS WITH PARALLEL, CROSSED, AND V-SHAPED ANGLED RIBS [J].
HAN, JC ;
ZHANG, YM ;
LEE, CP .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1991, 113 (03) :590-596
[10]   INVESTIGATION OF HEAT-TRANSFER AND FRICTION FOR RIB-ROUGHENED SURFACES [J].
HAN, JC ;
GLICKSMAN, LR ;
ROHSENOW, WM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1978, 21 (08) :1143-1156