Diagnostic Accuracy of Ultrasonography in Retained Soft Tissue Foreign Bodies: A Systematic Review and Meta-analysis

被引:63
|
作者
Davis, Joshua [1 ]
Czerniski, Byron [1 ]
Au, Arthur [2 ]
Adhikari, Srikar [3 ]
Farrell, Isaac [3 ]
Fields, J. Matthew [2 ]
机构
[1] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Dept Emergency Med, Philadelphia, PA 19107 USA
[3] Univ Arizona, Dept Emergency Med, Tucson, AZ USA
关键词
GUIDED REMOVAL; EMERGENCY PHYSICIANS; PATIENT PERCEPTION; BEDSIDE ULTRASOUND; SONOGRAPHY; MANAGEMENT; EXTREMITIES; HAND; LOCALIZATION; EXPERIENCE;
D O I
10.1111/acem.12714
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
ObjectivesOpen wounds with the potential for retained foreign bodies are frequently seen in the emergency department (ED). Common foreign bodies, such as wood or glass, are often missed on physical examination and conventional radiography. The increased use of ultrasonography (US) in the ED presents an opportunity to better identify retained soft tissue foreign bodies, and understanding of its test characteristics is desirable. The authors set out to determine the test characteristics of US for detection of soft tissue foreign bodies by performing a systematic review and meta-analysis of the existing literature. MethodsThis was a thorough, systematic review of OVID Medline, SCOPUS, and Cochrane databases and a limited review of Directory of Open Access Journals, Google Scholar, and ClinicalTrials.gov to identify clinical studies examining the diagnostic accuracy of US in the identification of retained soft tissue foreign bodies. Studies were selected for full-text review by two independent reviewers to determine if they met inclusion criteria. Results were pooled for test characteristics using STATA and assessed for risk of bias and applicability using the QUADAS-2 tool. ResultsThis systematic search strategy identified 5,059 unique articles, and 17 articles met inclusion criteria. Pooled sensitivity and specificity were, respectively, 72% (95% confidence interval [CI]=57% to 83%) and 92% (95% CI=88% to 95%). Overall quality of the studies was low and interstudy heterogeneity was high (I-2=90%, 95% CI=80% to 100%). ConclusionsUltrasonography is highly specific and moderately sensitive in the identification of retained soft tissue foreign bodies; however, studies to date have a high degree of heterogeneity and a high risk of bias.
引用
收藏
页码:777 / 787
页数:11
相关论文
共 50 条
  • [31] Diagnostic accuracy of ultrasonography compared with magnetic resonance imaging in diagnosing disc displacement of the temporomandibular joint: A systematic review and meta-analysis
    Thapar, Prem R.
    Nadgere, Jyoti B.
    Iyer, Janani
    Salvi, Neelam A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02) : 446 - 454
  • [32] Clinical presentation of childhood soft tissue sarcomas: a systematic review and meta-analysis
    Ni Cheallaigh, Lorna
    Liu, Jo-Fen
    Fern, Lorna
    Winyard, Paul
    Walker, David
    Ball-Gamble, Ashley
    Shanmugavadivel, Dhurgshaarna
    ARCHIVES OF DISEASE IN CHILDHOOD, 2024, 109 (02) : 113 - 120
  • [33] Pharmacologic Intervention for Retained Placenta A Systematic Review and Meta-analysis
    Duffy, James M. N.
    Mylan, Sophie
    Showell, Marian
    Wilson, Matthew J. A.
    Khan, Khalid S.
    OBSTETRICS AND GYNECOLOGY, 2015, 125 (03) : 711 - 718
  • [34] Diagnostic Accuracy of Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta Spectrum: A Systematic Review and Meta-analysis
    Abdelaziz, Suzi
    El-Goly, Nour A.
    Maged, Ahmed M.
    Bassiouny, Nehal
    El-Demiry, Nihal
    Shamel, Ahmed
    MATERNAL-FETAL MEDICINE, 2025, 7 (01) : 15 - 21
  • [35] A Bayesian approach for diagnostic accuracy of malignant peripheral nerve sheath tumors: a systematic review and meta-analysis
    Martin, Enrico
    Geitenbeek, Ritchie T. J.
    Coert, J. Henk
    Hanff, David F.
    Graven, Laura H.
    Grunhagen, Dirk J.
    Verhoef, Cornelis
    Taal, Walter
    NEURO-ONCOLOGY, 2021, 23 (04) : 557 - 571
  • [36] The diagnostic accuracy of a point-of-care ultrasound protocol for shock etiology: A systematic review and meta-analysis
    Stickles, Sean P.
    Carpenter, Christopher R.
    Gekle, Robert
    Kraus, Chadd K.
    Scoville, Caryn
    Theodoro, Daniel
    Vu Huy Tran
    Ubinas, George
    Raio, Christopher
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2019, 21 (03) : 406 - 417
  • [37] Glucagon for Relief of Acute Esophageal Foreign Bodies and Food Impactions: A Systematic Review and Meta-Analysis
    Peksa, Gary D.
    DeMott, Joshua M.
    Slocum, Giles W.
    Burkins, Jaxson
    Gottlieb, Michael
    PHARMACOTHERAPY, 2019, 39 (04): : 463 - 472
  • [38] Clinical Characteristics and Interventions for Ingested Magnetic Foreign Bodies in Children: A Systematic Review and Meta-analysis
    Xie, Siqi
    Bai, Jianxi
    Huang, Yanbing
    Lin, Sheng
    Zhang, Hong
    Fang, Yifan
    Zhang, Bing
    INDIAN PEDIATRICS, 2023, 60 (05) : 397 - 403
  • [39] Clinical Characteristics and Interventions for Ingested Magnetic Foreign Bodies in Children: A Systematic Review and Meta-analysis
    Siqi Xie
    Jianxi Bai
    Yanbing Huang
    Sheng Lin
    Hong Zhang
    Yifan Fang
    Bing Zhang
    Indian Pediatrics, 2023, 60 : 397 - 403
  • [40] Diagnostic Accuracy of Transcranial Doppler for Brain Death Confirmation: Systematic Review and Meta-Analysis
    Chang, J. J.
    Tsivgoulis, G.
    Katsanos, A. H.
    Malkoff, M. D.
    Alexandrov, A. V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 408 - 414