Diagnostic Accuracy of Ultrasonography in Retained Soft Tissue Foreign Bodies: A Systematic Review and Meta-analysis

被引:63
|
作者
Davis, Joshua [1 ]
Czerniski, Byron [1 ]
Au, Arthur [2 ]
Adhikari, Srikar [3 ]
Farrell, Isaac [3 ]
Fields, J. Matthew [2 ]
机构
[1] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Dept Emergency Med, Philadelphia, PA 19107 USA
[3] Univ Arizona, Dept Emergency Med, Tucson, AZ USA
关键词
GUIDED REMOVAL; EMERGENCY PHYSICIANS; PATIENT PERCEPTION; BEDSIDE ULTRASOUND; SONOGRAPHY; MANAGEMENT; EXTREMITIES; HAND; LOCALIZATION; EXPERIENCE;
D O I
10.1111/acem.12714
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
ObjectivesOpen wounds with the potential for retained foreign bodies are frequently seen in the emergency department (ED). Common foreign bodies, such as wood or glass, are often missed on physical examination and conventional radiography. The increased use of ultrasonography (US) in the ED presents an opportunity to better identify retained soft tissue foreign bodies, and understanding of its test characteristics is desirable. The authors set out to determine the test characteristics of US for detection of soft tissue foreign bodies by performing a systematic review and meta-analysis of the existing literature. MethodsThis was a thorough, systematic review of OVID Medline, SCOPUS, and Cochrane databases and a limited review of Directory of Open Access Journals, Google Scholar, and ClinicalTrials.gov to identify clinical studies examining the diagnostic accuracy of US in the identification of retained soft tissue foreign bodies. Studies were selected for full-text review by two independent reviewers to determine if they met inclusion criteria. Results were pooled for test characteristics using STATA and assessed for risk of bias and applicability using the QUADAS-2 tool. ResultsThis systematic search strategy identified 5,059 unique articles, and 17 articles met inclusion criteria. Pooled sensitivity and specificity were, respectively, 72% (95% confidence interval [CI]=57% to 83%) and 92% (95% CI=88% to 95%). Overall quality of the studies was low and interstudy heterogeneity was high (I-2=90%, 95% CI=80% to 100%). ConclusionsUltrasonography is highly specific and moderately sensitive in the identification of retained soft tissue foreign bodies; however, studies to date have a high degree of heterogeneity and a high risk of bias.
引用
收藏
页码:777 / 787
页数:11
相关论文
共 50 条
  • [21] Ultrasonography as a diagnostic modality and therapeutic adjuvant in the management of soft tissue foreign bodies in the lower extremities
    Blankstein, A
    Cohen, I
    Heiman, Z
    Salai, M
    Diamant, L
    Heim, M
    Chechick, A
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2001, 3 (06): : 411 - 413
  • [22] Diagnostic Accuracy of Female Pelvic Ultrasonography in Differentiating Precocious Puberty From Premature Thelarche: A Systematic Review and Meta-analysis
    Nguyen, Nam Nhat
    Huynh, Linh Ba Phuong
    Do, Minh Duc
    Yang, Tien Yun
    Tsai, Meng-Che
    Chen, Yang-Ching
    FRONTIERS IN ENDOCRINOLOGY, 2021, 12
  • [23] Diagnostic Performance of Conventional X-ray for Detecting Foreign Bodies in the Upper Digestive Tract: A Systematic Review and Diagnostic Meta-Analysis
    Yang, Ta-Wei
    Yu, Yi-Chung
    Lin, Yen-Yue
    Hsu, Shih-Chang
    Chu, Karen Chia-Wen
    Hsu, Chin-Wang
    Bai, Chyi-Huey
    Chang, Cheng-Kuang
    Hsu, Yuan-Pin
    DIAGNOSTICS, 2021, 11 (05)
  • [24] Diagnostic accuracy of rapid immunoassays for heparin-induced thrombocytopenia A systematic review and meta-analysis
    Sun, Lova
    Gimotty, Phyllis A.
    Lakshmanan, Suvasini
    Cuker, Adam
    THROMBOSIS AND HAEMOSTASIS, 2016, 115 (05) : 1044 - 1055
  • [25] Diagnostic Accuracy of Intraoperative Tools for Detecting Endometriosis: A Systematic Review and Meta-analysis
    Maheux-Lacroix, Sarah
    Belanger, Mathieu
    Pinard, Lorence
    Lemyre, Madeleine
    Laberge, Philippe
    Boutin, Amelie
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2020, 27 (02) : 433 - +
  • [26] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 (07) : 1269 - 1278
  • [27] Diagnostic Accuracy of MRI for Solid Renal Masses: A Systematic Review and Meta-analysis
    Frank, Robert A.
    Dawit, Haben
    Bossuyt, Patrick M. M.
    Leeflang, Mariska
    Flood, Trevor A.
    Breau, Rodney H.
    McInnes, Matthew D. F.
    Schieda, Nicola
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1172 - 1184
  • [28] Diagnostic Accuracy of Imaging Findings in Pleural Empyema: Systematic Review and Meta-Analysis
    Zettinig, Desiree
    D'Antonoli, Tugba Akinci
    Wilder-Smith, Adrian
    Bremerich, Jens
    Roth, Jan A.
    Sexauer, Raphael
    JOURNAL OF IMAGING, 2022, 8 (01)
  • [29] Diagnostic Performance of Ultrasonography for Identification of Small Bowel Obstruction; a Systematic Review and Meta-analysis
    Motavaselian, Mohsen
    Farrokhi, Mehrdad
    Khouzani, Parisa Jafari
    Fard, Atousa Moghadam
    Daeizadeh, Fatemeh
    Pourrahimi, Mahya
    Mehrabani, Reyhaneh
    Amani-Beni, Reza
    Farrokhi, Masoud
    Sarnaghy, Faezeh Jalayer
    Mir, Asal
    Tavakoli, Reza
    Fadavian, Heidar
    Mehdinezhad, Reza
    Masoudikabir, Parisa
    Moallem, Maoumeh
    Karami, Tohid
    Roohinezhad, Roozbeh
    Yazdani, Yalda
    Ghasemi, Didar
    Rezaeizadeh, Farideh
    Hadizadeh, Alireza
    Sarallah, Rojin
    Shafigh, Ashkan
    Aminpour, Solmaz
    Esfahani, Amirhossein
    Mirabdali, Seyedsaber
    Hosseini, Zahrasadat
    Saharkhiz, Farahnaz
    Khodsiani, Mehrzad
    Tirtashi, Fahimeh Ebrahimi
    Dehkordi, Shabnam Esmailian
    Amini, Nafise Sadat
    Aran, Mahsa
    Abolghasemfard, Zohreh
    Sanjarinia, Nazanin
    Abdollahi, Zeynab
    Abediankenari, Fatemeh
    Ghadirzadeh, Erfan
    Khodashenas, Mehran
    Jahanshahi, Ali
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2024, 12 (01)
  • [30] Diagnostic accuracy of transabdominal ultrasonography for gallbladder polyps: systematic review
    Martin, Erin
    Gill, Richdeep
    Debru, Estifanos
    CANADIAN JOURNAL OF SURGERY, 2018, 61 (03) : 200 - 207