Diagnostic Accuracy of Ultrasonography in Retained Soft Tissue Foreign Bodies: A Systematic Review and Meta-analysis

被引:63
|
作者
Davis, Joshua [1 ]
Czerniski, Byron [1 ]
Au, Arthur [2 ]
Adhikari, Srikar [3 ]
Farrell, Isaac [3 ]
Fields, J. Matthew [2 ]
机构
[1] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Dept Emergency Med, Philadelphia, PA 19107 USA
[3] Univ Arizona, Dept Emergency Med, Tucson, AZ USA
关键词
GUIDED REMOVAL; EMERGENCY PHYSICIANS; PATIENT PERCEPTION; BEDSIDE ULTRASOUND; SONOGRAPHY; MANAGEMENT; EXTREMITIES; HAND; LOCALIZATION; EXPERIENCE;
D O I
10.1111/acem.12714
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
ObjectivesOpen wounds with the potential for retained foreign bodies are frequently seen in the emergency department (ED). Common foreign bodies, such as wood or glass, are often missed on physical examination and conventional radiography. The increased use of ultrasonography (US) in the ED presents an opportunity to better identify retained soft tissue foreign bodies, and understanding of its test characteristics is desirable. The authors set out to determine the test characteristics of US for detection of soft tissue foreign bodies by performing a systematic review and meta-analysis of the existing literature. MethodsThis was a thorough, systematic review of OVID Medline, SCOPUS, and Cochrane databases and a limited review of Directory of Open Access Journals, Google Scholar, and ClinicalTrials.gov to identify clinical studies examining the diagnostic accuracy of US in the identification of retained soft tissue foreign bodies. Studies were selected for full-text review by two independent reviewers to determine if they met inclusion criteria. Results were pooled for test characteristics using STATA and assessed for risk of bias and applicability using the QUADAS-2 tool. ResultsThis systematic search strategy identified 5,059 unique articles, and 17 articles met inclusion criteria. Pooled sensitivity and specificity were, respectively, 72% (95% confidence interval [CI]=57% to 83%) and 92% (95% CI=88% to 95%). Overall quality of the studies was low and interstudy heterogeneity was high (I-2=90%, 95% CI=80% to 100%). ConclusionsUltrasonography is highly specific and moderately sensitive in the identification of retained soft tissue foreign bodies; however, studies to date have a high degree of heterogeneity and a high risk of bias.
引用
收藏
页码:777 / 787
页数:11
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Ultrasonography for Rotator Cuff Tears: A Systematic Review and Meta-analysis
    Farooqi, Ali S.
    Lee, Alexander
    Novikov, David
    Kelly, Ann Marie
    Li, Xinning
    Kelly, John D.
    Parisien, Robert L.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (10)
  • [2] Diagnostic accuracy of point-of-care ultrasonography for intussusception in children: A systematic review and meta-analysis
    Lin-Martore, Margaret
    Firnberg, Maytal T.
    Kohn, Michael A.
    Kornblith, Aaron E.
    Gottlieb, Michael
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2022, 58 : 255 - 264
  • [3] Diagnostic accuracy of ultrasonography for the confirmation of endotracheal tube intubation: a systematic review and meta-analysis
    Li, Xuxia
    Zhang, Jiapeng
    Karunakaran, Monica
    Hariharan, Vishnu Shankar
    MEDICAL ULTRASONOGRAPHY, 2023, 25 (01) : 72 - 81
  • [4] Ultrasonography for foreign bodies in the soft tissue
    Yolcu, Sadiye
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (07) : 977 - 978
  • [5] Point-of-Care Ultrasonography for the Diagnosis of Skin and Soft Tissue Abscesses: A Systematic Review and Meta-analysis
    Gottlieb, Michael
    Avila, Jacob
    Chottiner, Mark
    Peksa, Gary D.
    ANNALS OF EMERGENCY MEDICINE, 2020, 76 (01) : 67 - 77
  • [6] Accuracy of Ultrasonography in Breast Implant Rupture Diagnosis: Systematic Review and Meta-Analysis
    Lacerda Macedo, Ana Cristina
    Carvalho, George
    Uggioni, Maria L. R.
    Bavaresco, Daniela V.
    Simon, Carla S.
    Silva, Fabio Cruz Mateus
    Rosa, Maria I.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 148 (05) : 939 - 947
  • [7] Diagnostic accuracy of bowel ultrasonography in patients with inflammatory bowel disease: a systematic review and meta-analysis
    Malik, Sheza
    Venugopalan, Sruthi
    Tenorio, Bettina Gabrielle
    Khan, Shahab R.
    Loganathan, Priyadarshini
    Navaneethan, Udayakumar
    Mohan, Babu P.
    ANNALS OF GASTROENTEROLOGY, 2024, 37 (01): : 54 - 63
  • [8] Necrotizing Soft Tissue Infection: Diagnostic Accuracy of Physical Examination, Imaging, and LRINEC Score A Systematic Review and Meta-Analysis
    Fernando, Shannon M.
    Tran, Alexandre
    Cheng, Wei
    Rochwerg, Bram
    Kyeremanteng, Kwadwo
    Seely, Andrew J. E.
    Inaba, Kenji
    Perry, Jeffrey J.
    ANNALS OF SURGERY, 2019, 269 (01) : 58 - 65
  • [9] Diagnostic Accuracy of Ultrasonography in the Detection of Postsurgical Recurrence in Crohn's Disease: A Systematic Review with Meta-analysis
    Rispo, Antonio
    Imperatore, Nicola
    Testa, Anna
    Nardone, Olga Maria
    Luglio, Gaetano
    Caporaso, Nicola
    Castiglione, Fabiana
    INFLAMMATORY BOWEL DISEASES, 2018, 24 (05) : 977 - 988
  • [10] Diagnostic Accuracy of Ultrasonography Method of Graf in the Detection of Developmental Dysplasia of the Hip: A Meta-Analysis and Systematic Review
    Chavoshi, Mohammadreza
    Mirshahvalad, Seyed Ali
    Mahdizadeh, Mehrzad
    Zamani, Fatemeh
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (03): : 297 - 305