In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

被引:9
|
作者
Steen, Henning [1 ]
Andre, Florian [1 ]
Korosoglou, Grigorios [1 ]
Mueller, Dirk [2 ]
Hosch, Waldemar [3 ]
Kauczor, Hans-Ulrich [3 ]
Giannitsis, Evangelos [1 ]
Katus, Hugo A. [1 ]
机构
[1] Univ Heidelberg, Dept Cardiol, D-69120 Heidelberg, Germany
[2] Philips GmbH, Healthcare Div, D-20099 Hamburg, Germany
[3] Univ Heidelberg, Dept Diagnost & Intervent Radiol, D-69120 Heidelberg, Germany
关键词
Multislice CT; Coronary stents; CT angiography; Artifacts; Coronary artery disease; In-stent; Restenosis; SPIRAL COMPUTED-TOMOGRAPHY; DUAL-SOURCE CT; ROW CT; ANGIOGRAPHY; RESTENOSIS; VISUALIZATION;
D O I
10.1016/j.ejrad.2010.08.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A <= 2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values <0.05 were regarded statistically significant. Results: In-stent lumen diameter >60% for group C stents was significantly larger and CNR was significantly lower (both p < 0.05) for sharp kernels (CD; XCD) when compared to groups A/B. The FWHM-method showed significantly smaller in-stent lumen diameter (p < 0.05) when compared to the manual method. Conclusion: 256-MDCT could potentially be employed for clinical assessment of stent patency in stents >3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents <= 3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [41] Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study
    Zhang, Xinghua
    Yang, Li
    Ju, Haiyue
    Zhang, Fan
    Wu, Jian
    He, Bin
    Chen, Yundai
    EUROPEAN RADIOLOGY, 2012, 22 (09) : 1896 - 1903
  • [42] Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography
    Choi, HS
    Choi, BW
    Choe, KO
    Choi, DH
    Yoo, KJ
    Kim, MI
    Kim, J
    RADIOGRAPHICS, 2004, 24 (03) : 787 - 800
  • [43] CT Evaluation of Small-Diameter Coronary Artery Stents: Effect of an Integrated Circuit Detector with Iterative Reconstruction
    Geyer, Lucas L.
    Glenn, G. Russell
    De Cecco, Carlo Nicola
    Van Horn, Mark
    Canstein, Christian
    Silverman, Justin R.
    Krazinski, Aleksander W.
    Kemper, Jenny M.
    Bucher, Andreas
    Ebersberger, Ullrich
    Costello, Philip
    Bamberg, Fabian
    Schoepf, U. Joseph
    RADIOLOGY, 2015, 276 (03) : 706 - 714
  • [44] Next generation coronary CT angiography: in vitro evaluation of 27 coronary stents
    Tobias Gassenmaier
    Nils Petri
    Thomas Allmendinger
    Thomas Flohr
    David Maintz
    Wolfram Voelker
    Thorsten A. Bley
    European Radiology, 2014, 24 : 2953 - 2961
  • [45] Current concepts in multi-detector row CT evaluation of the coronary arteries: Principles, techniques, and anatomy
    Pannu, HK
    Flohr, TG
    Corl, FM
    Fishman, EK
    RADIOGRAPHICS, 2003, 23 : S111 - S125
  • [46] Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions
    Cury, RC
    Ferencik, M
    Achenbach, S
    Pomerantsev, E
    Nieman, K
    Moselewski, F
    Abbara, S
    Jang, IK
    Brady, TJ
    Hoffmann, U
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) : 345 - 350
  • [47] Pericardial Fat is a Risk Factor for Severe Coronary Artery Stenosis in Young People: A Study with 256-Slice Computed Tomography
    Li, Cai-Ying
    Gao, Bu-Lang
    Liao, Qi-Bin
    Pan, Tong
    Zhang, Dan
    Kou, Chen-Guang
    Xiang, Cheng
    Wang, Chen
    Jia, Fang-Ying
    Zheng, Cai-Duan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (02) : 430 - 435
  • [48] Low-dose prospectively gated 256-slice coronary computed tomographic angiography
    Weigold, Wm Guy
    Olszewski, Mark E.
    Walker, Matthew J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 217 - 230
  • [49] One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography
    Yamasaki, Yuzo
    Nagao, Michinobu
    Kawanami, Satoshi
    Kamitani, Takeshi
    Sagiyama, Koji
    Yamanouchi, Torahiko
    Sakamoto, Ichiro
    Yamamura, Kenichiro
    Yabuuchi, Hidetake
    Honda, Hiroshi
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 697 - 704
  • [50] One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography
    Yuzo Yamasaki
    Michinobu Nagao
    Satoshi Kawanami
    Takeshi Kamitani
    Koji Sagiyama
    Torahiko Yamanouchi
    Ichiro Sakamoto
    Kenichiro Yamamura
    Hidetake Yabuuchi
    Hiroshi Honda
    European Radiology, 2017, 27 : 697 - 704