Calibration of CMS Electromagnetic Calorimeter at LHC startup

被引:0
|
作者
Paramatti, Riccardo
机构
来源
XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010) | 2011年 / 293卷
关键词
D O I
10.1088/1742-6596/293/1/012045
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The first 7 TeV LHC collisions recorded with the CMS detector have been used to perform a channel-by-channel calibration of the electromagnetic calorimeter (ECAL). Decays of pi(0) and eta into two photons as well as the azimuthal symmetry of the average energy deposition at a given pseudorapidity are utilized to equalize the response of the individual channels. The ECAL comprises a central barrel section and two endcaps. Based on an integrated luminosity of similar to 100 nb(-1), a channel-by-channel in-situ calibration precision of 1.15% has been achieved in the barrel ECAL in the pseudorapidity region vertical bar eta vertical bar < 0.8. The energy scale of the ECAL has been investigated and found to agree with the simulation to within 1% in the barrel and 3% in the endcaps.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Commissioning, Performance and Calibration of Crystals of the CMS Electromagnetic Calorimeter
    Yang, Yong
    35TH INTERNATIONAL CONFERENCE OF HIGH ENERGY PHYSICS (ICHEP 2010), 2010,
  • [32] The CMS crystal calorimeter for the LHC
    Zach, F
    HIGH ENERGY PHYSICS, VOLS I AND II, 2001, : 1254 - 1256
  • [33] The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
    Obertino, M. M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [34] The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
    Gras, Philippe
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [35] THE CMS ELECTROMAGNETIC CALORIMETER STATUS: PERFORMANCE WITH COSMIC AND FIRST LHC DATA
    Biino, Cristina
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 431 - 437
  • [36] Inter-calibration of the CMS electromagnetic calorimeter with isolated electrons
    Agostino, L.
    Daskalakis, G.
    Govoni, P.
    Malgeri, L.
    Paganoni, M.
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2007, 34 (03) : N67 - N83
  • [37] Pre-calibration of the CMS electromagnetic calorimeter with cosmic rays
    Tabarelli de Fatis, T.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 800 - 802
  • [38] The electromagnetic calorimeter of CMS
    Funk, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 92 - 96
  • [39] The CMS electromagnetic calorimeter
    Bloch, P
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 241 - 249
  • [40] The CMS electromagnetic calorimeter
    Paganoni, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 461 - 465