In vivo determination of the frequency response of the tooth root canal impedance versus distance from the apical foramen

被引:3
作者
Rambo, Marcos V. H. [1 ]
Gamba, Humberto R. [1 ]
Ratzke, Alexandre S. [1 ]
Schneider, Fabio K. [1 ]
Maia, Joaquim M. [1 ]
Ramos, Carlos A. S. [2 ]
机构
[1] Fed Univ Technol Parana UTFPR, Grad Ctr Elect Engn & Informat CPGEI, Curitiba, Parana, Brazil
[2] State Univ Londrina UEL, Fac Dent, Londrina, Parana, Brazil
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4352354
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Working length (WL) determination is a key factor to the endodontic therapy or root canal treatment success. Almost all therapy procedures depend on this measure and the wrong WL determination may produce severe consequences, like post-therapeutic pain and the need of a new root canal treatment. Electronic foramen locators (EFL) have been replacing the traditional radiographic imaging as they are faster, easier to use and have a higher success rate when measuring WL. EFLs are based on the root canal impedance assessment between two electrodes: one fixed on the endodontic file that is inserted into the root canals and the other positioned at oral mucosa membrane. There are only few reported studies that qualify or quantify the root canal impedance characteristics. The present work aims to determine the module of tooth root canal frequency response. The preliminary results show the frequency response module variation as a function of endodontic file position inside the root canal and reinforce the methods based on relative impedance over frequency analysis used in modern EFLs.
引用
收藏
页码:570 / +
页数:2
相关论文
共 19 条
  • [1] The ability of Root ZX apex locator to reduce the frequency of overestimated radiographic working length
    ElAyouti, A
    Weiger, R
    Löst, C
    [J]. JOURNAL OF ENDODONTICS, 2002, 28 (02) : 116 - 119
  • [2] Frequency of overinstrumentation with an acceptable radiographic working length
    ElAyouti, A
    Weiger, R
    Löst, C
    [J]. JOURNAL OF ENDODONTICS, 2001, 27 (01) : 49 - 52
  • [3] An in vitro evaluation of the accuracy of the Root ZX in the presence of various irrigants
    Jenkins, JA
    Walker, WA
    Schindler, WG
    Flores, CM
    [J]. JOURNAL OF ENDODONTICS, 2001, 27 (03) : 209 - 211
  • [4] TOOTH LENGTH DETERMINATION - A REVIEW
    KATZ, A
    TAMSE, A
    KAUFMAN, AY
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1991, 72 (02): : 238 - 242
  • [5] ELECTRONIC CANAL LENGTH MEASUREMENT
    KOBAYASHI, C
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 79 (02): : 226 - 231
  • [6] NEW ELECTRONIC CANAL MEASURING DEVICE BASED ON THE RATIO METHOD
    KOBAYASHI, C
    SUDA, H
    [J]. JOURNAL OF ENDODONTICS, 1994, 20 (03) : 111 - 114
  • [7] Numerical computation of impedances of a human tooth for estimation of the root canal length
    Krizaj, D
    Jan, J
    Valencic, V
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) : 746 - 748
  • [8] MCDONALD N J, 1992, Dental Clinics of North America, V36, P293
  • [9] Meredith N, 1997, ENDOD DENT TRAUMATOL, V13, P126
  • [10] Root canal length measurement in teeth with electrolyte compensation
    Nam, KC
    Kim, SC
    Lee, SJ
    Kim, YJ
    Kim, NG
    Kim, DW
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (02) : 200 - 204