Determination of alkyl methylphosphonates and methylphosphonic acid by capillary electrophoresis with a diode-array spectrophotometric detector

被引:2
作者
Aleksenko, S. S. [1 ]
Tret'yakova, S. V. [1 ]
Mandych, V. G. [1 ]
机构
[1] Saratov Mil Inst Biol & Chem Safety, Saratov 410037, Russia
关键词
alkyl methylphosphonates; methylphosphonic acid; capillary electrophoresis; diode-array; AGENT DEGRADATION-PRODUCTS; GAS-CHROMATOGRAPHIC DETERMINATION; CHEMICAL WARFARE AGENTS; MASS SPECTROMETRY; SEPARATION; IDENTIFICATION; TRACE;
D O I
10.1134/S1061934811040022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Method of capillary electrophoresis with a diode-array detector was used to study the conditions of the separation of three alkyl methylphosphonates and methylphosphonic acid, hydrolysis products of nerve agents. The optimal conditions providing their separation and determination are reported (background electrolyte based on 100 mM boric acid with the addition of 10 mM of phenylphosphonic acid (pH 6.0); voltage +30 kV, detection wavelength 210 nm, electrokinetic introduction of the sample (10 kV, 10 sec), separation time below 10 min). Calibration curve for all the compounds was linear in the concentration range 0.05-1.0 mg/mL, the correlation coefficient was 0.999 in all cases. The procedure was tested for river and ground waters containing a mixture of isopropyl, isobutyl, pinacolyl methylphosphonates and methylphosphonic acid. Relative standard deviations of the migration times under the conditions of the repeatability of the results lie in the range 1.9-2.7% (n = 5), the relative standard deviation of the reduced peak areas vary from 1.2 to 7.0%.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [21] DETERMINATION OF CINACALCET HYDROCHLORIDE BY CAPILLARY ELECTROPHORESIS WITH PHOTODIODE ARRAY DETECTION
    AlShehri, Mona
    Darwish, Ibrahim
    Sultan, Maha
    Maher, Hadir
    Alzoman, Nourah
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (01) : 27 - 37
  • [22] Determination of Methylphosphonic Acid and Alkyl Methylphosphonic Acid Esters in Soils by Liquid Chromatography-High-Resolution Mass Spectrometry
    Vokuev, M. F.
    Braun, A. V.
    Baygildiev, T. M.
    Rybalchenko, I. V.
    Rodin, I. A.
    INORGANIC MATERIALS, 2023, 59 (14) : 1396 - 1405
  • [23] HYALURONIC ACID DETECTION FROM NATURAL EXTRACT BY DIODE ARRAY-CAPILLARY ELECTROPHORESIS METHODS
    Teodor, Eugenia Dumitra
    Truica, Georgiana
    Radu, Gabriel Lucian
    REVUE ROUMAINE DE CHIMIE, 2012, 57 (03) : 223 - 227
  • [24] Determination of flavonoids in plant material by HPLC with diode-array and electro-array detections
    Mattila, P
    Astola, J
    Kumpulainen, J
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (12) : 5834 - 5841
  • [25] Determination of amines by capillary electrophoresis with pulse voltammetric detector
    Wang, LS
    Yang, XY
    Mo, JY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (01): : 56 - 58
  • [26] Capillary electrophoresis detector using a light emitting diode and optical fibres
    Butler, PAG
    Mills, B
    Hauser, PC
    ANALYST, 1997, 122 (09) : 949 - 953
  • [27] Determination of curcuminoids in substances and dosage forms by cyclodextrin-mediated capillary electrophoresis with diode array detection
    Marakova, Katarina
    Mikus, Peter
    Piest'ansky, Juraj
    Havranek, Emil
    CHEMICAL PAPERS, 2011, 65 (04) : 398 - 405
  • [28] STABILITY-INDICATING CAPILLARY ELECTROPHORESIS METHOD WITH PHOTODIODE ARRAY DETECTOR FOR DETERMINATION OF LENALIDOMIDE IN PHARMACEUTICAL PREPARATION
    Alshehrt, M. M.
    Maher, H. M.
    Alzoman, N. Z.
    Sultan, M. A.
    Darwish, I. A.
    DIGEST JOURNAL OF NANOMATERIALS AND BIOSTRUCTURES, 2013, 8 (02) : 855 - 867
  • [29] Development of a method for simultaneous analysis of caffeine and taurine in energy drinks by micellar electrokinetic chromatography with diode-array detector
    Alves, Alane Cangani
    Meinhart, Adriana Dillenburg
    Teixeira Filho, Jose
    Godoy, Helena Teixeira
    FOOD SCIENCE AND TECHNOLOGY, 2019, 39 : 673 - 682
  • [30] Analysis of Roller Ball Pen Water Ink by Capillary Electrophoresis with Photodiode Array Detector
    Zhao Peng-cheng
    Wang Yan-ji
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (04) : 1028 - 1031