Test-Retest Reliability of Arterial Spin Labeling With Common Labeling Strategies

被引:207
作者
Chen, Yufen
Wang, Danny J. J. [3 ]
Detre, John A. [1 ,2 ]
机构
[1] Univ Penn, Dept Radiol, Ctr Funct Neuroimaging, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Neurol, Ctr Funct Neuroimaging, Philadelphia, PA 19104 USA
[3] Univ Calif Los Angeles, Dept Neurol, Los Angeles, CA 90024 USA
基金
美国国家卫生研究院;
关键词
magnetic resonance imaging; cerebral blood flow; arterial spin labeling; reproducibility; repeatability; pCASL; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; PERFUSION MRI; MAGNETIC-RESONANCE; 3.0; T; ACETAZOLAMIDE CHALLENGE; QUANTIFYING CBF; HUMAN BRAIN; REPRODUCIBILITY; QUANTIFICATION;
D O I
10.1002/jmri.22345
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the test-retest reproducibility of three variants of arterial spin labeling (ASL): pseudo-continuous (pCASL), pulsed (PASL) and continuous (CASL). Materials and Methods: Twelve healthy subjects were scanned on a 3.0T scanner with PASL, CASL, and pCASL. Scans were repeated within-session, after 1 hour, and after 1 week to assess reproducibility at different scan intervals. Results: Comparison of within-subject coefficients of variation (wsCV) demonstrated high within-session reproducibility (ie, low wsCV) for CASL-based methods (gray matter [GM] wsCV for pCASL: 3.5% +/- 0.02%, CASL: 4.1% +/- 0.07%) compared to PASL (wsCV: 7.5% +/- 0.06%), due to the higher signal-to-noise ratio (SNR) associated with continuous labeling, evident in the 20% gain in temporal SNR and 58% gain in raw SNR for pCASL relative to PASL. At the 1-week scan interval, comparable reproducibility between PASL (GM wsCV 9.2% +/- 0.12%) and pCASL (GM wsCV 8.5% +/- 0.14%) was observed, indicating the dominance of physiological fluctuations. Conclusion: Although all three approaches are capable of measuring cerebral blood flow within a few minutes of scanning, the high precision and SNR of pCASL, with its insensitivity to vessel geometry, make it an appealing method for future ASL application studies.
引用
收藏
页码:940 / 949
页数:10
相关论文
共 37 条
[1]   Multisection cerebral blood flow MR imaging with continuous arterial spin labeling [J].
Alsop, DC ;
Detre, JA .
RADIOLOGY, 1998, 208 (02) :410-416
[2]   Statistics notes: Measurement error proportional to the mean .23. [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7049) :106-106
[3]   XE-133 INHALATION METHOD - ANALYSIS OF REPRODUCIBILITY - SOME OF ITS PHYSIOLOGICAL IMPLICATIONS [J].
BLAUENSTEIN, UW ;
HALSEY, JH ;
WILSON, EM ;
WILLS, EL ;
RISBERG, J .
STROKE, 1977, 8 (01) :92-102
[4]   Quantifying CBF with arterial spin labeling [J].
Buxton, RB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (06) :723-726
[5]   Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H215O positron emission tomography [J].
Carroll, TJ ;
Teneggi, V ;
Jobin, M ;
Squassante, L ;
Treyer, V ;
Hany, TF ;
Burger, C ;
Wang, L ;
Bye, T ;
von Schulthess, GK ;
Buck, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (09) :1149-1156
[6]   Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields [J].
Dai, Weiying ;
Garcia, Dairon ;
de Bazelaire, Cedric ;
Alsop, David C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1488-1497
[7]   Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system [J].
Detre, JA ;
Alsop, DC .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (02) :115-124
[8]   Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories [J].
Floyd, TF ;
Ratcliffe, SJ ;
Wang, JJ ;
Resch, B ;
Detre, JA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) :649-655
[9]   QUANTITATIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN-METABOLISM IN MAN USING O-15 AND POSITRON EMISSION TOMOGRAPHY - THEORY, PROCEDURE, AND NORMAL VALUES [J].
FRACKOWIAK, RSJ ;
LENZI, GL ;
JONES, T ;
HEATHER, JD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) :727-736
[10]   Acquisition Time and Reproducibility of Continuous Arterial Spin-Labeling Perfusion Imaging at 3T [J].
Gevers, S. ;
Majoie, C. B. L. M. ;
van den Tweel, X. W. ;
Lavini, C. ;
Nederveen, A. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (05) :968-971