On-line fouling/cleaning detection by measuring electric resistance-equipment development and application to milk fouling detection and chemical cleaning monitoring

被引:51
作者
Chen, XD [1 ]
Li, DXY [1 ]
Lin, SXQ [1 ]
Özkan, N [1 ]
机构
[1] Univ Auckland, Dept Chem & Mat Engn, Auckland, New Zealand
关键词
fouling; cleaning; soft-deposit; process monitoring;
D O I
10.1016/S0260-8774(03)00085-2
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An electrical resistance method, which has the potential to measure the extent of soft material fouling such as milk fouling on the surface of process equipment in situ and in real time, is described. An experimental fouling unit with the appropriate attachments has been devised and used to monitor the fouling build-up using the electrical resistance method. Reconstituted skim milks with solid contents of 10-30 wt.% were used to produce milk foulings, and these milk foulings were cleaned using a cleaning solution with 0.5 wt.% NaOH. Using the fouling unit, it was possible to measure the thermal resistance (essentially measuring heat flux) and electrical resistance simultaneously. As a result, the relationship between the electrical resistance and the thermal resistance during both fouling build-ups and cleaning processes was established. It has been shown that this technique is effective for measuring the extent of fouling, and it has the potential to be modified further so that it can be adopted in real process industries. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 24 条
[1]  
Bott T.R., 1995, FOULING HEAT EXCHANG
[2]  
BOTT TR, 1996, 2 EUR THERM SCI 14 U
[3]   Hydration and removal of supported phospholipid films in aqueous surfactant solutions [J].
Colberg, MT ;
Carnes, K ;
Saez, AE ;
Grant, CS ;
Hutchinson, K ;
Hesterberg, D .
THIN SOLID FILMS, 1998, 327 :247-251
[4]  
CORRIEU G, 1979, FOOD PROCESS ENG, V1, P165
[5]   AN AUTOMATED DIMENSION MEASUREMENT SYSTEM FOR SOFT BIOLOGICAL-MATERIALS [J].
DIEHL, KC ;
VANGELDER, MF ;
BYLER, RK .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1990, 47 (02) :133-138
[6]  
FRYER PJ, 1997, CHEM ENG FOOD IND, P365
[7]  
FRYER PJ, 1989, PROCESS ENG FOOD IND, P131
[8]   NONCONTACT MEASUREMENT OF FILM THICKNESS BY THE PHOTOTHERMAL DEFLECTION METHOD [J].
FUJIMORI, H ;
ASAKURA, Y ;
SUZUKI, K ;
UCHIDA, S .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (10) :1759-1764
[9]   AN AUTOMATIC MICROMETER FOR MEASURING SOFT ELECTRICALLY CONDUCTIVE MATERIALS [J].
GALE, GE ;
GRIFFITHS, P .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (05) :447-451
[10]   A THICKNESS MEASURING DEVICE USING PNEUMATIC GAUGING TO DETECT THE SAMPLE [J].
GALE, GE .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (11) :1566-1571