One-shot-phase-shifting full range Fourier domain optical coherence tomography by reference wavefront tilting

被引:0
作者
Makita, S [1 ]
Yasuno, Y [1 ]
Endo, T [1 ]
Aoki, G [1 ]
Itoh, M [1 ]
Yatagai, T [1 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
来源
Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX | 2005年 / 5690卷
关键词
optical coherence tomography; Fourier domain OCT; full range FD-OCT; tilting wavefront; phase-shifting; M-scan; simultaneous detection;
D O I
10.1117/12.589141
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel optical scheme for a full range Fourier domain optical coherence tomography (FD-OCT) is presented. This method avoids a mechanical scan for phase-shifting (mechanical M-scan) which enables a full range FD-OCT. A tilting reference wavefront is used to make variable phase offset of spectral interferometric fringes. Several spectral fringes are detected by a two dimensional CCD camera simultaneously. One axis of the CCD camera is occupied with the optical spectral axis, and the other axis is employed for phase offset variation. A few spectral fringes are extracted and used for phase-shifting algorithm. The principle of this system is confirmed with a plane mirror sample.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 16 条
  • [1] Optical coherence tomography by "Spectral Radar":: Dynamic range estimation and in vivo measurements of skin
    Andretzky, P
    Lindner, MW
    Herrmann, JM
    Schultz, A
    Konzog, M
    Kiesewetter, F
    Häusler, G
    [J]. OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING IV, PROCEEDINGS OF, 1999, 3567 : 78 - 87
  • [2] Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    Choma, MA
    Sarunic, MV
    Yang, CH
    Izatt, JA
    [J]. OPTICS EXPRESS, 2003, 11 (18): : 2183 - 2189
  • [3] Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
  • [4] HUANG D, 1991, SCIENCE, V254, P118
  • [5] Performance of fourier domain vs. time domain optical coherence tomography
    Leitgeb, R
    Hitzenberger, CK
    Fercher, AF
    [J]. OPTICS EXPRESS, 2003, 11 (08): : 889 - 894
  • [6] Real-time measurement of in vitro flow by Fourier-domain color Doppler optical coherence tomography
    Leitgeb, RA
    Schmetterer, L
    Hitzenberger, CK
    Fercher, AF
    Berisha, F
    Wojtkowski, M
    Bajraszewski, T
    [J]. OPTICS LETTERS, 2004, 29 (02) : 171 - 173
  • [7] MALACARA D, WILEY SERIES PURE AP, P501
  • [8] In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
    Nassif, N
    Cense, B
    Park, BH
    Yun, SH
    Chen, TC
    Bouma, BE
    Tearney, GJ
    de Boer, JF
    [J]. OPTICS LETTERS, 2004, 29 (05) : 480 - 482
  • [9] EXTENDED AVERAGING TECHNIQUE FOR DERIVATION OF ERROR-COMPENSATING ALGORITHMS IN PHASE-SHIFTING INTERFEROMETRY
    SCHMIT, J
    CREATH, K
    [J]. APPLIED OPTICS, 1995, 34 (19) : 3610 - 3619
  • [10] In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical Doppler tomography
    White, BR
    Pierce, MC
    Nassif, N
    Cense, B
    Park, BH
    Tearney, GJ
    Bouma, BE
    Chen, TC
    de Boer, JF
    [J]. OPTICS EXPRESS, 2003, 11 (25): : 3490 - 3497